QCS001 Process List

DUNS NumberSupplierSupplier NumberProcess CodeProcess GroupProcess DescriptionSpecificationProcess CommentsAddressCityStateZip CodeContact NameContact FunctionContact Phone
0733230813P PROCESSING, INCPQA602200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602200SANODIZEChromic Acid Anodize2ZZP00001 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201DWI-LMA1 5/10/20121702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201DW1-LMA1, good thru 04/27/20181702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602240APAINT and PRIMEPrime and PaintMIL-F-18264 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 1702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
0733230813P PROCESSING, INCPQA602148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001DWI-LMA2 6/17/20101702 S KNIGHT STREETWICHITAKS672131304Jon ThomasQA Manager(316)943-0731
052418126AAA PLATING AND INSPECTION004806,00023200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200B1ANODIZESulfuric Acid Anodize Alternative for Type I/IBMIL-A-8625 Type IIBCoating Weight must not exceed 600mg/sq.ft when processing Type IIB. Per F-16 M and P, Type IIB may replace Type 1 or 1B, only at this facility.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200CANODIZEHard AnodizeMIL-A-8625, Type III 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200HANODIZEChromic Acid AnodizeSTP 58-209Not approved for Type IA.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200NANODIZESulfuric Acid AnodizeLCP77-2037/LADC-P-77-2037Not approved for Grade B.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200QANODIZEHard AnodizeLCP77-1063/LADC-P-77-1063Not approved for Type IV.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB. Approved Paint Stripping Procedure MPP-718 Rev. C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD MPP-314 Rev. N/C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD MPP-314 Rev. N/C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016Approved Procedure MPP-319 Rev. B.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725Only Type I applied at this facility.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources.Only AMS-C-27725 Type I applied at this facility.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023243FUEL TANK COATINGSeal Bond Primer ApplicationFPS-3035 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613846%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Approved for FPS-3035 Rev. P Processing. Limited to application of Form 2 primer per approved planning.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD MPP-805 Rev. C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023203ION-VAPOR DEPOSITIONIVDMIL-C -83488 / FPS-3083 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Includes Zones 1A, 1B and 1C. See FWQPL for Approved Materials.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD MPP-151 Rev. K.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD MPP-151 Rev. K.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD MPP-151 Rev. K.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD MPP-227 Rev. T.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD MPP-151 Rev. K.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility qualification approval expires 4-30-2019. Approved PCD MPP-151 Rev. J.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023240APAINT and PRIMEPrime and PaintMIL-F-18264 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023230APLATINGCadmiumQQ-P-416 Type I 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023230BPLATINGCadmiumQQ-P-416 Type II 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023230JPLATINGCadmium (P3 ONLY)C-0491Approved PCD MPP-411 Rev. N/C. Not approved for Aluminum.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023230MPLATINGCadmium (C-130 ONLY)Process Spec 0491Not approved for Aluminum.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023231BPLATINGCadmium - Vacuum DepositedMIL-C-8837 Type II 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure MPP-165 Rev. D.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023110C2PRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure MPP-166 Rev. C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved Procedure MPP-165 Rev. D.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001Approved Procedure MPP-166 Rev. C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001Approved Procedure MPP-167 Rev. C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD's MPP-168 Aluminum Etch Rev. A, MPP-169 Titanium Etch Rev. N/C, MPP-170 CRES Etch Rev. A and MPP-171 Steel Etch Rev. N/C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD's MPP-168 Aluminum Etch Rev. A, MPP-169 Titanium Etch Rev. N/C, MPP-170 CRES Etch Rev. A and MPP-171 Steel Etch Rev. N/C.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101Approved PCD MPP-170 Rev. A.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD MPP-168 Rev. A.424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023620PRE-PENETRANT ETCHTitanium Alloys-Alkaline/Acid Metal Remova MethodsSTP57-401 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
052418126AAA PLATING AND INSPECTION004806,00023256SOLID FILM LUBRICANTSSFL CLASS V1 ONLYAS1701 424 DIXON ST.COMPTONCA90222Mike KegleyQA Manager(310)637-1066
128841934AAXON LABS INC010450100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101Spec number 340 Rev A.4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007Procedure Spec 300K and 340A approved.4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources. 4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources. 4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Procedure 245 A dated 11-02-094113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Procedure 247 rev B4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved procedure Spec number 240, Rev. M. Approved for fracture critical hardware.4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201F35 Facility Re-qualification Due: August 31, 20174113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Approved for Non-Critical Parts and Critical Parts, Procedure Spec. number 240, Rev J4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure 600 Rev H4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450146B1PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGG01Procedure 600 Rev H4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Procedure 600 Rev H4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Aaxon 647 original- Approved Marietta M and P (Aluminum only)4113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
128841934AAXON LABS INC010450619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Aaxon 647 Original Approved Marietta M and P based on Workflow ID- 340526704113 MURRAY AVEHALTOM CITYTX761171714Chris MoonQA Manager(817)626-0310
008248569ABRASIVE FINISHING CO.PQA003,24956310SHOT PEENINGShot PeeningAMS 2430NO POST PEENING CHEMICAL PROCESSING CAPABILITIES.14920 S. MAIN ST.GARDENACA90248Mike DemkeQA Manager(310)323-7175
008248569ABRASIVE FINISHING CO.PQA003,24956310BSHOT PEENINGShot PeeningFPS-1032NO POST PEENING CHEMICAL PROCESSING CAPABILITIES.14920 S. MAIN ST.GARDENACA90248Mike DemkeQA Manager(310)323-7175
008248569ABRASIVE FINISHING CO.PQA003,24956311SHOT PEENINGShot PeeningSTP51-501NO POST PEENING CHEMICAL PROCESSING CAPABILITIES.14920 S. MAIN ST.GARDENACA90248Mike DemkeQA Manager(310)323-7175
025458829ACE CLEARWATER ENTERPRISES INCPQA135161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 7322 QUIMBY AVENUEPARAMOUNTCA90723Elizabeth RamirezQuality Engineer(310)538-5380
025458829ACE CLEARWATER ENTERPRISES INCPQA135171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 7322 QUIMBY AVENUEPARAMOUNTCA90723Elizabeth RamirezQuality Engineer(310)538-5380
025458829ACE CLEARWATER ENTERPRISES INCPQA135600BHEAT TREATMENTSAluminumSTP 54-101 7322 QUIMBY AVENUEPARAMOUNTCA90723Elizabeth RamirezQuality Engineer(310)538-5380
025458829ACE CLEARWATER ENTERPRISES INCPQA135600EHEAT TREATMENTSAluminumLCP73-1039 / P52005LIMITED TO SALT BATH AND ANNEALING7322 QUIMBY AVENUEPARAMOUNTCA90723Elizabeth RamirezQuality Engineer(310)538-5380
025458829ACE CLEARWATER ENTERPRISES INCPQA135606HEAT TREATMENTSAluminumAMS-2770LIMITED TO SALT BATH AND ANNEALING7322 QUIMBY AVENUEPARAMOUNTCA90723Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDES ZONES 1A, 1B, 1C; Must use QCS-001 approved source for pre-penetrant etch.19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 approved source for pre-penetrant etch.19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008401AWELDINGFusion WeldingSTP 55-104 19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008401B1WELDINGFusion WeldingLADC-P-74-2022 19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008404BWELDINGResistance WeldingMIL-W-6858 19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008404EWELDINGResistance WeldingC-1421Approved PCD APP 013, rev.J with WIP 7.5.7-1, rev.02. Approved cleaniing PCD APP number 001, rev. J. Excludes titanium.19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
009534801ACE CLEARWATER ENTERPRISES, IN007600,00147,40008406DWELDINGFusionFPS-1095, AluminumClass B welds only19815 MAGELLAN DRTORRANCECA905021107Elizabeth RamirezQuality Engineer(310)538-5380
884242830ADVANCED AERO COATINGS, LLCS10601200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601200LANODIZESulfuric Acid AnodizeSTP 58-208PI005-02 Rev N/C approved by Danal9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601240APAINT and PRIMEPrime and PaintMIL-F-18264 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
884242830ADVANCED AERO COATINGS, LLCS10601619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301 9004 TRINITY BLVDHURSTTX76053David BullardQA Manager 
075801746ADVANCED COATINGS TECHNIQUESPQA011200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011200HANODIZEChromic Acid AnodizeSTP 58-209 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011200LANODIZESulfuric Acid AnodizeSTP 58-208 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011200SANODIZEChromic Acid Anodize2ZZP00001 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approval Limited to Class 1 Type 1 Only311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Not approved for P-3 hardware311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009NDT 039311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008Embritlement and stress relief max temp 375F311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02NON-FRACTURE CRITICAL PARTS ONLY.311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved procedure NDT 015, Issue 1 (WF 48169877). Not approved for Fracture Critical Hardware.311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011240APAINT and PRIMEPrime and PaintMIL-F-18264 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011230BPLATINGCadmiumQQ-P-416 Type II 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011146B6PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGL03NDT-003 issue 8 / WF ID 36579949311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001NDT 015-1 WF ID -47631539311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001NDT 015-1 Issue 2 - WF ID -52845299311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Aluminum etch for LPI only, no special etch / NDT-003 Issue 8 / WF ID 36579949311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
075801746ADVANCED COATINGS TECHNIQUESPQA011252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005Type II, IV and V311 WYANDANCH AVE.N. BABYLONNY117041581Leandro AparicioQA Manager(631)643-4555
039603477AERO COMPONENTS, INC.011469,100366200XANODIZEPhosphoric Acid Anodizing of AluminumSTP 58-211Approved :Aero Comp - CP040 rev 3 - WF ID -415336585124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366818BONDING AND COMPOSITESStructural Adhesive Bonding of Metal AssembliesPS 0120 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366820BONDING AND COMPOSITESFabrication of Glass Fabric Base, Epoxy Resin, L/PSTP61-213 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366825BONDING AND COMPOSITESAdhesive Bonding of Homeycomb AssembliesSTP60-103 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366827BONDING AND COMPOSITESFabrication of Adhesive Bonded Honeycomb SandwichPS 2017 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366240APAINT and PRIMEPrime and PaintMIL-F-18264 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
039603477AERO COMPONENTS, INC.011469,100366247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 5124 KALTENBRUN RDFORT WORTHTX761196400Becki CateQA Manager(817)572-3003
008391682AERO ENGINEERING and MANUFACTURI100309,00428816BONDING AND COMPOSITESApplication of AdhesivesPS 0101Approved PCD WI-0101 Rev. A.CO OF CALIFORNIA28217 AVENUE CROCKERVALENCIACA913551249Cheung HoQA Manager(661)295-0875
008391682AERO ENGINEERING and MANUFACTURI100309,00428401AWELDINGFusion WeldingSTP 55-104Excludes Class A. GTAW only.CO OF CALIFORNIA28217 AVENUE CROCKERVALENCIACA913551249Cheung HoQA Manager(661)295-0875
008391682AERO ENGINEERING and MANUFACTURI100309,00428401DWELDINGFusion WeldingAWS D17.1GTAW only.CO OF CALIFORNIA28217 AVENUE CROCKERVALENCIACA913551249Cheung HoQA Manager(661)295-0875
006319065AERO METAL FINISHINGPQA017200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017200CANODIZEHard AnodizeMIL-A-8625, Type III 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017200SANODIZEChromic Acid Anodize2ZZP00001 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDES ZONES 1B AND 1C2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PCIR 1824, 08/23/992150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201AMF PC201 Rev New approved per WF ID -48720784 dated 2/16/152150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017240APAINT and PRIMEPrime and PaintMIL-F-18264 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PER AMF 118 REV D DATED 2-12-092150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001AMF PG001 Rev New approved per WF ID -48264696 dated 12/23/20142150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
006319065AERO METAL FINISHINGPQA017251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 2150 N. LARK DR.FENTONMO63026Cindy OttermanQA Manager(636)677-1650
025995010AERO SPACE WELDERSPQA020401AWELDINGFusion WeldingSTP 55-104Class B welds only. A requires additional process procedure approval.2470 DOREEN ST.GRAND PRAIRIETX75050Josh GreenQA Manager(972)988-9121
025995010AERO SPACE WELDERSPQA020401DWELDINGFusion WeldingAWS D17.1 2470 DOREEN ST.GRAND PRAIRIETX75050Josh GreenQA Manager(972)988-9121
025995010AERO SPACE WELDERSPQA020406AWELDINGFusionFPS-1095, Steel 2470 DOREEN ST.GRAND PRAIRIETX75050Josh GreenQA Manager(972)988-9121
025995010AERO SPACE WELDERSPQA020406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 2470 DOREEN ST.GRAND PRAIRIETX75050Josh GreenQA Manager(972)988-9121
025995010AERO SPACE WELDERSPQA020406DWELDINGFusionFPS-1095, Aluminum 2470 DOREEN ST.GRAND PRAIRIETX75050Josh GreenQA Manager(972)988-9121
025995010AERO SPACE WELDERSPQA020406EWELDINGFusionFPS-1095, Titanium 2470 DOREEN ST.GRAND PRAIRIETX75050Josh GreenQA Manager(972)988-9121
960324218AERO-TECH ENGINEERING, INC.013548167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 5555 N 119TH ST WMAIZEKS67101Paul Richardson ext 123QA Manager(316)942-8604
960324218AERO-TECH ENGINEERING, INC.013548168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 5555 N 119TH ST WMAIZEKS67101Paul Richardson ext 123QA Manager(316)942-8604
960324218AERO-TECH ENGINEERING, INC.013548240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 5555 N 119TH ST WMAIZEKS67101Paul Richardson ext 123QA Manager(316)942-8604
009540824AEROCRAFT HEAT TREATING CO INCPQA016,00431169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness only15701 MINNESOTA AVEPARAMOUNTCA907234196Imtiyaz AhmedQA Manager(562)634-3311
009540824AEROCRAFT HEAT TREATING CO INCPQA016,00431601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 15701 MINNESOTA AVEPARAMOUNTCA907234196Imtiyaz AhmedQA Manager(562)634-3311
009540824AEROCRAFT HEAT TREATING CO INCPQA016,00431601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 15701 MINNESOTA AVEPARAMOUNTCA907234196Imtiyaz AhmedQA Manager(562)634-3311
009540824AEROCRAFT HEAT TREATING CO INCPQA016,00431601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 15701 MINNESOTA AVEPARAMOUNTCA907234196Imtiyaz AhmedQA Manager(562)634-3311
009540824AEROCRAFT HEAT TREATING CO INCPQA016,00431602HEAT TREATMENTSTitaniumAMS-H-81200 15701 MINNESOTA AVEPARAMOUNTCA907234196Imtiyaz AhmedQA Manager(562)634-3311
835056623AEROFAB INC.PQA024160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 722 RIDGE ROADNICKTOWNPA15762Paul Rosenbaum Jr.QA Manager(814)948-6015
835056623AEROFAB INC.PQA024161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 722 RIDGE ROADNICKTOWNPA15762Paul Rosenbaum Jr.QA Manager(814)948-6015
835056623AEROFAB INC.PQA024167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 722 RIDGE ROADNICKTOWNPA15762Paul Rosenbaum Jr.QA Manager(814)948-6015
835056623AEROFAB INC.PQA024168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 722 RIDGE ROADNICKTOWNPA15762Paul Rosenbaum Jr.QA Manager(814)948-6015
835056623AEROFAB INC.PQA024171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 722 RIDGE ROADNICKTOWNPA15762Paul Rosenbaum Jr.QA Manager(814)948-6015
835056623AEROFAB INC.PQA024606HEAT TREATMENTSAluminumAMS-2770 722 RIDGE ROADNICKTOWNPA15762Paul Rosenbaum Jr.QA Manager(814)948-6015
801689803AEROSPACE FABRICATIONS OF GEOR009224325FORMINGFormingSTP51-302 Hot forming methods listed in Appendix A Section 1.3 onlyLMCO PCD STP51-302 REVC 2-17-2017 Including 7000 alloysINC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)AFOG Heat Treating Proc Rev UINC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224600BHEAT TREATMENTSAluminumSTP 54-101Limted part thick.greater than 0.016 inches, ammonium flouborate waived.INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224600CHEAT TREATMENTSAluminumProcess Spec C-0521AFOG Heat Treating Proc Rev WINC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
801689803AEROSPACE FABRICATIONS OF GEOR009224606HEAT TREATMENTSAluminumAMS-2770 INC.305 BUTLER INDUSTRIAL DRDALLASGA301325022Brad Massey, QA MgrQA Manager(770)505-8801
458798519AEROSPACE SURFACE TREATMENTPQA124200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BNot approved for F35 hardware13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124200HANODIZEChromic Acid AnodizeSTP 58-209 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124200LANODIZESulfuric Acid AnodizeSTP 58-208PCI630 Issue 2 approved by Danals13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124609HEAT TREATMENTSSteelAMS-2759 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124230BPLATINGCadmiumQQ-P-416 Type II 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011) 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
458798519AEROSPACE SURFACE TREATMENTPQA124619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301 13 TATTERSALL WAY*************CHELMSFORD INDUSTRIAL PARK CHELMSFORD CM1 3UBUNITED KINGDOM  Rowshan RowshangoharQA Manager(012)796-816
241696046AEROSPACE WELDINGS00630,PQA116210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PCP 21B rev C approved WF ID -47605503890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068QCP02B Is 1 rev NC FPI 31-36 rev E / WF 39022419890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567QCP02B Is 1 rev NC FPI 31-36 rev E / WF 39022419890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)PCP 21B Rev C approved WF ID -47605503890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170PCP 21B rev C approved WF ID -47605503890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCP 21B rev C approved WF ID -47605503890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116401AWELDINGFusion WeldingSTP 55-104 890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
241696046AEROSPACE WELDINGS00630,PQA116404CWELDINGResistance WeldingSTP 55-005Limited to class B and C890 MICHELE-BOHECBLAINVILLE, QUEBEC, CANAD70J7C5E2Yves DeryQA Manager 
884670944AEROSPACE WELDING, INC.PQA026,09755404BWELDINGResistance WeldingMIL-W-6858 2035 GRANVILLE AVELOS ANGLESCA90025John GreenQA Manager(310)473-8684
884670944AEROSPACE WELDING, INC.PQA026,09755404CWELDINGResistance WeldingSTP 55-005 2035 GRANVILLE AVELOS ANGLESCA90025John GreenQA Manager(310)473-8684
884670944AEROSPACE WELDING, INC.PQA026,09755404EWELDINGResistance WeldingC-1421Approval excludes Group III material. Approved PCD APS-3, E, Amend. number 1. Approved cleaning PCD APS-1E for cleaning of aluminum only.2035 GRANVILLE AVELOS ANGLESCA90025John GreenQA Manager(310)473-8684
884670944AEROSPACE WELDING, INC.PQA026,09755412AWELDINGFlash WeldingSTP 55-601 2035 GRANVILLE AVELOS ANGLESCA90025John GreenQA Manager(310)473-8684
884670944AEROSPACE WELDING, INC.PQA026,09755412BWELDINGFlash WeldingPS C-1424 2035 GRANVILLE AVELOS ANGLESCA90025John GreenQA Manager(310)473-8684
884670944AEROSPACE WELDING, INC.PQA026,09755412CWELDINGFlash WeldingLCP74-1075/LADC-P-74-1075 2035 GRANVILLE AVELOS ANGLESCA90025John GreenQA Manager(310)473-8684
079543096AIRCRAFT REPAIR and OVERHAULS10955,PQA144,27063200XANODIZEPhosphoric Acid Anodizing of AluminumSTP 58-211 1186 N. GROVE STREETANAHEIMCA92806-2109Mike BevanQA Manager(714)630-9494
079543096AIRCRAFT REPAIR and OVERHAULS10955,PQA144,27063817BONDING AND COMPOSITESAdhesive Bonding, Structural, Metal to MetalSTP60-005Approval limited to PAA clean and primer application SOW. PCD 0040-1.0 Rev. N/C to STM 30-104 Type IE1186 N. GROVE STREETANAHEIMCA92806-2109Mike BevanQA Manager(714)630-9494
079543096AIRCRAFT REPAIR and OVERHAULS10955,PQA144,27063818BONDING AND COMPOSITESStructural Adhesive Bonding of Metal AssembliesPS 0120Approval limited to Hologram Program Non-honeycomb Metal Bonded Assemblies per QTR 243. PCD 0040-3.0 Rev. N/C to STM30-102 Type I Class IC and Type II Grade A Class 1C.1186 N. GROVE STREETANAHEIMCA92806-2109Mike BevanQA Manager(714)630-9494
079543096AIRCRAFT REPAIR and OVERHAULS10955,PQA144,27063819BONDING AND COMPOSITESFabrication of H/C Nonmetallic Faced SandwichSTP60-105M and P approval of Test Report No. 259 and ARO PCD 0050-1 0 Rev. New.1186 N. GROVE STREETANAHEIMCA92806-2109Mike BevanQA Manager(714)630-9494
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BExcludes Type 1C.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Jose Delgadillo Level III.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes LCP72-1068.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02Approved Procedure QAP 102-CL02, Revision A dated 10-12-2004.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved for Non Critical Parts and Critical Parts. QAP102-PC201 Rev. NC dated 6-25-20045216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 03/31/2019.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742Steve Senne Level III.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved PCD QAP 101-STP53-301 Rev. C.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Approved Procedure QAP 101-PC301 Rev. B.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622145NON-DESTRUCTIVE TESTINGX-Ray5PTPCG05APPROVED BASED ON T. CHRISTENSON AUDIT.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Approved for Non-Critical Parts and Critical Parts. QAP 102-CG06, Rev. A dated 7-28-2004.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622240APAINT and PRIMEPrime and PaintMIL-F-18264 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PER QPS-102.1 AL, REV. B DATED 11/20015216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622110C2PRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PER QPS 102.1 TI., REV. E DATED 10-2009.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622146B1PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGG01PER QPS 102.1 AL, REV. B DATED 11/20/015216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622146B6PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGL03PER QPS 102.1 AL, REV. B DATED 11/20/015216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved Procedure QPS-LMA-PG001 Rev. G.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001Approved Procedure QPS-LMA-PG001 Rev. G.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
028307718AIRCRAFT X-RAY LABORATORIESPQA062,00622619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved Procedure PP 13000-STP57-301 Rev. Original.5216 PACIFIC BLVD.HUNTINGTON PARKCA90255Juan PerezQA Manager(323)587-4141
041812272AIRWAY WELDING, INC.PQA088401DWELDINGFusion WeldingAWS D17.1 2415 E. HIGH STREETJACKSONMI492033421Rick RogersQA Manager(517)789-6125
041812272AIRWAY WELDING, INC.PQA088406DWELDINGFusionFPS-1095, Aluminum 2415 E. HIGH STREETJACKSONMI492033421Rick RogersQA Manager(517)789-6125
041812272AIRWAY WELDING, INC.PQA088408AWELDINGFUSION WELDING - F-352ZZP00013Cleaning by Eaton in Jackson, MI. Titanium cleaning procedure AP 1178, revision AP.2415 E. HIGH STREETJACKSONMI492033421Rick RogersQA Manager(517)789-6125
008257818AJAX FORGE COMPANY INC.100373,00950513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 1956 EST 48TH STREETLOS ANGELESCA900582006Misael HernandezQA Manager(323)582-6307
008257818AJAX FORGE COMPANY INC.100373,00950513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 1956 EST 48TH STREETLOS ANGELESCA900582006Misael HernandezQA Manager(323)582-6307
074956467ALAN MANES MACHINE, INC001867240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 2421 INTERNATIONAL BLVDFORT COLLINSCO805241433Glenn Seibert x104QA Manager(970)224-3311
080241550ALBANY AEROSTRUCTURES COMPOSIT012316,05723831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. LLC5995 W AMELIA EARHART DRSALT LAKE CITYUT841163746Lecia AndersonQA Manager(801)869-5451
080241550ALBANY AEROSTRUCTURES COMPOSIT012316,05723242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725Includes both Salt Lake City FacilitiesLLC5995 W AMELIA EARHART DRSALT LAKE CITYUT841163746Lecia AndersonQA Manager(801)869-5451
080241550ALBANY AEROSTRUCTURES COMPOSIT012316,05723134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Approved procedure 80516, rev. H by Vanproyen Includes both Salt Lake facilitiesLLC5995 W AMELIA EARHART DRSALT LAKE CITYUT841163746Lecia AndersonQA Manager(801)869-5451
080241550ALBANY AEROSTRUCTURES COMPOSIT012316,05723240APAINT and PRIMEPrime and PaintMIL-F-18264Includes both Salt Lake City FacilitiesLLC5995 W AMELIA EARHART DRSALT LAKE CITYUT841163746Lecia AndersonQA Manager(801)869-5451
080241550ALBANY AEROSTRUCTURES COMPOSIT012316,05723240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 LLC5995 W AMELIA EARHART DRSALT LAKE CITYUT841163746Lecia AndersonQA Manager(801)869-5451
243356560ALCOA CANADA CIE187586516CASTINGSCastings, Aerospace QualityLMA-PA090 4001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
243356560ALCOA CANADA CIE187586168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009Hardness only.4001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
243356560ALCOA CANADA CIE187586607HEAT TREATMENTSAluminum CastingsAMS-2771 4001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
243356560ALCOA CANADA CIE187586113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved Critical and Non Not Approved Fracture Critical. FPI 235.03.01 A APPendex4001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
243356560ALCOA CANADA CIE187586123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Approved 235.04.01 A Appendix4001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
243356560ALCOA CANADA CIE187586148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Aluminum Castings Only. Approved Procedure 225.03.03 Rev 14001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
243356560ALCOA CANADA CIE187586409WELDINGWeld Repair of CastingsAMS-2694 4001 DES LAURENTIDES (A-15) ELAVAL20H7L 3H7Dorina GligorQA Manager(450)680-2557
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BTY IB only. PCD: PPS1066 rev 3 / WF 53261699VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Hand Lay Fabric, Non-Critical Parts, Qualification Report 2ZZA00846VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933832ABONDING AND COMPOSITESJSF Epoxy Fabrication2ZZP00004 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396622%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Hand Lay Fabric, Non-Critical Parts, Qualification Report 2ZZA00846VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Limitation: Class 1A only Immersion only F-35 programSTRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922606HEAT TREATMENTSAluminumAMS-2770 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922609HEAT TREATMENTSSteelAMS-2759 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
339095904ALENIA AERMACCHI S.P.A.S01871110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417MRB only. PCD: 99-NT-0000-N325-130184 is 2 WF 49372434. Limitation: No Etch ApprovalSTATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Limitation: Must use QCS-001 approved source EtchingSTRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD: S-P-SCH-T-06 rev B - WF 50613589VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD 99NT0000N325110093 is 5 WF 51892054 / Limitation: Not approved for EtchingSTRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
339095904ALENIA AERMACCHI S.P.A.S01871113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201MRB only. PCD: 99-NT-0000-N325-130184 is 2 WF 49372434. Limitation: No Etch ApprovalSTATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires July 31 2019VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
339095904ALENIA AERMACCHI S.P.A.S01871113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201MRB only. Approved for Fracture Critical Parts, Facility Qual approval expires 7/31/2019STATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742PCD: IPR-NRX-013A r 1/WF 52479218STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301PCD: IPR-NRX-013A r 1/WF 52479218STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001PCD: 99/NT/0000/N325/140178 is 1 / WF 49146908VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
339095904ALENIA AERMACCHI S.P.A.S01871134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001MRB only PCD: 99_NT_0000_N325_120071 Is 2 and 99-NT-0000-N325-150340 rev 1 (Metal to Metal)STATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
339095904ALENIA AERMACCHI S.P.A.S01871139NON-DESTRUCTIVE TESTINGEddy CurrentLMA-PC002MRB PCD: 98_NT_0020_N325_120047 Is 1/WF 41913283) / Limitation - Alloy Groups i, II and VSTATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
339095904ALENIA AERMACCHI S.P.A.S01871139aNON-DESTRUCTIVE TESTINGEddy Current of Fracture/Durability Critical BoltsLMA-PC012MRB PCD: 98/NT_0020_N325_120047 is 1/WF 41913283/Approved-M Turconi, F Cortese, A EmilioSTATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933240APAINT and PRIMEPrime and PaintMIL-F-18264 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
339095904ALENIA AERMACCHI S.P.A.S01871240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 STATALE 32 BELLINZAGOCAMERI6028062Mr. Mirko Silvestri (+39)QA Manager(032)167-2155
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
SAPPQA933ALENIA AERMACCHI S.P.A.PQA933148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD: PPS1069 rev 2 / WF 52056373VIA P. FORESIA, 1VENEGONO SUPERIORE (VA), 21040Mr. Marco Poletto (+39)QA Manager(331)813-4032
PMSPQA922ALENIA AERMACCHI S.P.A.PQA922408AWELDINGFUSION WELDING - F-352ZZP00013PCD: IPS-NW-010A r 3/WF 53912163,IPS-NW-011A r 3/WF 53920096,IPS-NW-012A r 2/WF 54039455STRADA PRIVATA (AEROPORTO CASELLE)SAN MAURIZIO CANAVESE TO 10077Mr. Augusto Suppo (+39)QA Manager(011)996-0652
PMSPQA129ALENIA AERONAUTICA SPAPQA129200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: TY 1B onlyZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA128ALENIA AERONAUTICA SPAPQA128831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Applicable processes 2ZZP10000, 2ZZP10001 and 2ZZP10002ZONA ASI LOCALITA INCORONATAFOGGIA7771100Fabio Filaseta (+39)QA Manager(088)181-7327
PMSPQA128ALENIA AERONAUTICA SPAPQA128831BBONDING AND COMPOSITESJSF BMI Fiber Placement2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Applicable processes 2ZZP10000, 2ZZP10001 and 2ZZP10002ZONA ASI LOCALITA INCORONATAFOGGIA7771100Fabio Filaseta (+39)QA Manager(088)181-7327
PMSPQA129ALENIA AERONAUTICA SPAPQA129210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA128ALENIA AERONAUTICA SPAPQA128242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 ZONA ASI LOCALITA INCORONATAFOGGIA7771100Fabio Filaseta (+39)QA Manager(088)181-7327
PMSPQA129ALENIA AERONAUTICA SPAPQA129242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA129ALENIA AERONAUTICA SPAPQA129167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA129ALENIA AERONAUTICA SPAPQA129113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD: 99-NT-0000-N325-090044 is 7 / WF 50619638ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA129ALENIA AERONAUTICA SPAPQA129113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 01/31/2019ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA129ALENIA AERONAUTICA SPAPQA129134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001MRB only PCD: 99-NT-0000-N325-150340 rev 1 (Metal to Metal Bond Insp)ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA128ALENIA AERONAUTICA SPAPQA128134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001PCD: 99/NT/0000/N325/090047 is 6 / WF 52639270ZONA ASI LOCALITA INCORONATAFOGGIA7771100Fabio Filaseta (+39)QA Manager(088)181-7327
PMSPQA128ALENIA AERONAUTICA SPAPQA128240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 ZONA ASI LOCALITA INCORONATAFOGGIA7771100Fabio Filaseta (+39)QA Manager(088)181-7327
PMSPQA129ALENIA AERONAUTICA SPAPQA129240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Grandfathered / MIL-F-18264ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
PMSPQA128ALENIA AERONAUTICA SPAPQA128240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 ZONA ASI LOCALITA INCORONATAFOGGIA7771100Fabio Filaseta (+39)QA Manager(088)181-7327
PMSPQA129ALENIA AERONAUTICA SPAPQA129148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD 99/NT/0000/N325/090033 Ed./Issue 10 / WF 44894203ZONA ASI-LOCALITA BOSCOFANGONENOLA2080035Andrea Arvonio (+39)QA Manager(081)315-4278
072297682ALERT PLATING COMPANYS01506,PQA090916BONDING AND COMPOSITESConductive coating on non-metallic substratesFPS-3084Limited to Class I and P/N: 16E4003-7 and 16E4003-9 ONLY.9939 GLENOAKS BLVDSUN VALLEYCA91352Mussadiq HussainQA Manager(818)771-9304
600001028ALGATPQA008200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II KIBBUTZ ALONIM 30040ISRAEL 30040Mr. Baruch ItIk (+972)QA Manager(052)332-0244
600001028ALGATPQA008200LANODIZESulfuric Acid AnodizeSTP 58-208PCD: PS 3-5-3-4 rev 4 / WF 53023322KIBBUTZ ALONIM 30040ISRAEL 30040Mr. Baruch ItIk (+972)QA Manager(052)332-0244
060320702ALKEN INDUSTRIES INC.008270,15851167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 2175 5TH AVERONKONKOMANY117796217Thomas AramandaQA Manager(631)467-2000
060320702ALKEN INDUSTRIES INC.008270,15851168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 2175 5TH AVERONKONKOMANY117796217Thomas AramandaQA Manager(631)467-2000
128447955ALLOY PROCESSINGPQA035200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BApproved for Bldg. 1 Only.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035200HANODIZEChromic Acid AnodizeSTP 58-209Type I only (non-dyed). Approved for Bldg. 1 Only.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035200SANODIZEChromic Acid Anodize2ZZP00001 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD: AP-102-3 Rev. A1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016Approved PCD AP-102-2 Rev. L.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD AP-105-6 Rev. A.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Dave Sybenga PT Level 3.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes LCP72-1068.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD AP-004P Rev. N.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Bldg. 1 and 2 are Approved for Fracture Critical Parts. Facility qualification approval in Bldg. 1 expires 9-30-2017. Facility qualification approval in Bldg. 2 expires 4-30-2019. Approved PCD AP-004P Rev. N.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035240APAINT and PRIMEPrime and PaintMIL-F-18264Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014)Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014)Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD AP-101.2 Rev. J. Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved PCD AP-101.2 Rev. J. Approved PCD AP-101.3 Rev. H Local Pre-Pen Etch. Aluminum Etch Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001Approved PCD AP-101.7 Rev. I. Approved PCD AP-101.3 Rev. H Local Pre-Pen Etch.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
128447955ALLOY PROCESSINGPQA035619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD AP 101-8 Rev. B. Approved for Bldg. 1 and 2.1900 W. WALNUT STR.COMPTONCA Corey WilliamsQA Manager(310)635-9995
366186406ALP HAVACILIK SANAYI VE TICARE012515200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: Type IB onlyNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515202ANODIZETitanium AnodizeAMS-2488Limitation: Type 2 onlyNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016PCD: QMP-211 rev 0 / WF 54468042NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515606HEAT TREATMENTSAluminumAMS-2770Limitation: AL Alloys 2024, 6061 and 7075 / Thickness over .016 in / .41 mmNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515609HEAT TREATMENTSSteelAMS-2759Limitation: Precipitation Hardening OnlyNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3Limitation: Precipitation Hardening OnlyNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Limitation: Method A and Form DNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Limitation: Method A and Form D. PCD: QMP-030 Rev.3 / WF 50550514NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 3/31/2018NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515234BPLATINGElectroless NickelMIL-C-26074, Class 2 (AMS 2404 Class 2 effective 01-01-2014)High PhosphorousNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD: QMI-088-LM rev ORG / WF 35592696NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001PCD: QMI-382 rev 1 / WF 55358385 rev 1NO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001PCD: QMI-383 rev 0 / WF 53403579. Limitation: 13-8PHNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
366186406ALP HAVACILIK SANAYI VE TICARE012515251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010Limitation: Application on Titanium onlyNO:29/1-2/26110, ORGANIZE SANESKISEHIR8526110Murat UCAR (+90) (Ext 177)QA Manager(222)236-1300
004267332ALPINE PRODUCTS MANUFACTURING COMPANYPQA040210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Type 1 Class 1A and Class 32030 DRILL AVENUEDAYTONOH45414John JacobsQA Manager(937)278-5861
004267332ALPINE PRODUCTS MANUFACTURING COMPANYPQA040210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approval is limited to Class 1 and Type I2030 DRILL AVENUEDAYTONOH45414John JacobsQA Manager(937)278-5861
004267332ALPINE PRODUCTS MANUFACTURING COMPANYPQA040240APAINT and PRIMEPrime and PaintMIL-F-18264 2030 DRILL AVENUEDAYTONOH45414John JacobsQA Manager(937)278-5861
004267332ALPINE PRODUCTS MANUFACTURING COMPANYPQA040246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014)AP 0522030 DRILL AVENUEDAYTONOH45414John JacobsQA Manager(937)278-5861
064488166ALUM-ALLOY CO.INC.101262,40034512BCASTINGSNon-ferrous CastingsSTP53-400Aluminum Only.603 S HOPE AVEONTARIOCA917611824Clark D. HowellQA Manager(909)986-0410
008313926ALUMINUM DIE CASTING COMPANY,100377,26461512BCASTINGSNon-ferrous CastingsSTP53-400ALUMINUM DIE CASTINGS ONLY10775 SAN SEVAINE WAYMIRA LOMACA917521146Todd LeveckQA Manager(951)681-3900
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238510AFORGINGSAluminum ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238600BHEAT TREATMENTSAluminumSTP 54-101 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154BAR, PLATE and RAW FORGINGS3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
009637513ALUMINUM PRECISION PRODUCTS, I054065,054465,01238110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.APP-1.9-301 Rev. T.3333 W WARNER AVESANTA ANACA927045898Kal WongQA Manager(714)546-8125
083776955AMERICAN AIRCRAFT PRODUCTS, IN009230,09499169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness testing of aluminum only.15411 S BROADWAYGARDENACA902482207Jeremy JonesQA Manager(310)532-7434
083776955AMERICAN AIRCRAFT PRODUCTS, IN009230,09499170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Limited to Alum only.15411 S BROADWAYGARDENACA902482207Jeremy JonesQA Manager(310)532-7434
083776955AMERICAN AIRCRAFT PRODUCTS, IN009230,09499170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Limited to Alum only.15411 S BROADWAYGARDENACA902482207Jeremy JonesQA Manager(310)532-7434
083776955AMERICAN AIRCRAFT PRODUCTS, IN009230,09499171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 15411 S BROADWAYGARDENACA902482207Jeremy JonesQA Manager(310)532-7434
083776955AMERICAN AIRCRAFT PRODUCTS, IN009230,09499404CWELDINGResistance WeldingSTP 55-005Excludes Class A welds.C-1421J Number 1.9.1. Rev B15411 S BROADWAYGARDENACA902482207Jeremy JonesQA Manager(310)532-7434
083776955AMERICAN AIRCRAFT PRODUCTS, IN009230,09499404EWELDINGResistance WeldingC-1421Limited to Class B group I welds.15411 S BROADWAYGARDENACA902482207Jeremy JonesQA Manager(310)532-7434
SAPPQA993AMERICAN ALUMINUMPQA993512BCASTINGSNon-ferrous CastingsSTP53-400 324 COIT STREETIRVINGTONNJ07111Tom McCarthyQA Manager(973)372-3200
041403130ANODICS, INC.PQA052200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 4105 MURRAY AVE. (F-50P)HALTOM CITYTX76117Robert SonesQA Manager(817)281-2743
041403130ANODICS, INC.PQA052210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 4105 MURRAY AVE. (F-50P)HALTOM CITYTX76117Robert SonesQA Manager(817)281-2743
008479479ANODYNE, INC.R16000,PQA053,16000200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BTank Size 95 inch Length x 35 inch Width x 46 inch Depth.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BTank Size 95 inch Length x 35 inch Width x 46 inch Depth.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200CANODIZEHard AnodizeMIL-A-8625, Type III 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200HANODIZEChromic Acid AnodizeSTP 58-209 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD MPP-202 Rev. F.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200PANODIZEHard AnodizeProcess Spec C-0445Limited to Type II Only.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200P1ANODIZEHard AnodizePS0445 Hard Anodizing of Aluminum Alloys 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000200SANODIZEChromic Acid Anodize2ZZP00001 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD MPP-400 Rev. S.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD MPP-400 Rev. S.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD MPP-500 Rev. B.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD MPP 37-1 Rev. A.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD MPP-309 Rev. C2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000101BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionP54002 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Approved for aluminum only,must use QCS-001 approved processers for all other materials2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD MPP 6-1 Rev. A.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD MPP-6 Rev. H and MPP-6-LMA Rev. N/C. Not approved for Fracture Critical.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000240APAINT and PRIMEPrime and PaintMIL-F-18264 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000240APAINT and PRIMEPrime and PaintMIL-F-18264 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)Approved PCD MPP-16-1 Rev. B.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000230BPLATINGCadmiumQQ-P-416 Type IILimited to 160 ksi and under.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000230HPLATINGCadmiumSTP 58-001Not approved for 220 ksi and above.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000230JPLATINGCadmium (P3 ONLY)C-0491Approved PCD MPP-311 Rev. V. Not approved for 220 ksi and above. Limited to Type II.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000230MPLATINGCadmium (C-130 ONLY)Process Spec 0491Not approved for 220 ksi and above.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000234APLATINGElectroless NickelMIL-C-26074, Class 1 / (AMS 2404 Class 1 effective 01-01-2014)Low phosphoruous only per AMS 2404.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure MPP-11-1 Rev. D.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved Procedure MPP-11-LMA-PG001 Rev. A.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD MPP-11-1 Rev. D (Aluminum Only).2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD MPP-11-1 Rev. D, (Aluminum) and MPP-10-1 Rev. A (Corrosion Resistant Steels).2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD MPP-11-1 Rev. D.2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
008479479ANODYNE, INC.R16000,PQA053,16000252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005 2230 S. SUSAN ST.SANTA ANACA92704Rafaela SerranoQA Manager(714)549-3321
PMS100380APEX COMPOSITES INC.100380200XANODIZEPhosphoric Acid Anodizing of AluminumSTP 58-211 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380818BONDING AND COMPOSITESStructural Adhesive Bonding of Metal AssembliesPS 0120 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380820BONDING AND COMPOSITESFabrication of Glass Fabric Base, Epoxy Resin, L/PSTP61-213 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380825BONDING AND COMPOSITESAdhesive Bonding of Homeycomb AssembliesSTP60-103 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380827BONDING AND COMPOSITESFabrication of Adhesive Bonded Honeycomb SandwichPS 2017 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380833BONDING AND COMPOSITESComposite Parts Surveillance and QualificationLMA-D0010 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380844BONDING AND COMPOSITESFABRICATION OF EPOXY FOR C-130 PROGRAMSTP61-226Limited to part number 3366351-1414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
PMS100380APEX COMPOSITES INC.100380305CHEM MILLING / DESCALINGChemical MillingPS 0450 414 CHAMBER LOOPADAOK748212254Don KingQA Manager(580)436-6444
140539656APEX ENGINEERING INTERNATIONAL006891,26095210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405AEP-2.31-REV.E-2-24-2011,Class 1L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095600BHEAT TREATMENTSAluminumSTP 54-101 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095606HEAT TREATMENTSAluminumAMS-2770 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301AEP-2.37 REV. A 2-24-2011 (limited to conventional cleaning)L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095401AWELDINGFusion WeldingSTP 55-104 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
140539656APEX ENGINEERING INTERNATIONAL006891,26095404CWELDINGResistance WeldingSTP 55-005 L.L.C.1804 W 2ND ST NWICHITAKS672035703AeiQuality DeptQA Manager 
SAPPQA988ARCADIA AEROSPACE INDUSTRIESPQA988134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001 266 TWIN CREEK DRIVETALLASSEEAL36078Bob EvansQA Manager(941)205-5700
806983891ARCADIA AEROSPACE INDUSTRIES LS10146134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Approved AAI-NDI-049, New- Hitco, CA and AAI-NDI-056 Rev New GKN Tallassee AL/Punta Gorda FL28000 AIRPORT RD STE A11PUNTA GORDAFL339822454Jeffrey PhillipsVice President(941)205-5700
083321299ARCONIC INC.S00351513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351514FORGINGSForgingLMA-PA041 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351517FORGINGSAlum Alloy ForgingsSTM05-101 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351602HEAT TREATMENTSTitaniumAMS-H-81200 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
083321299ARCONIC INC.S00351130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 1600 HARVARD AVENEWBURGH HEIGHTSOH441053040Greg JudyQA Manager(216)641-4256
008241499ARCTURUS MANUFACTURING CORPORATION005363,01810514FORGINGSForgingLMA-PA041 6001 ARCTURUS AVENUEOXNARDCA93033Erin BolognaQA Manager 
041667502AREMAC HEAT TREATING, INC010219,14497167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD: AHT 10.0.1 Rev. A330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497600BHEAT TREATMENTSAluminumSTP 54-101 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497601A1HEAT TREATMENTSSteelLCP73-2020/LADC-P-73-2020 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497601BHEAT TREATMENTSSteelSTP 54-006, Above 220 KSIExcludes Aermet 100 and AF 1410 materials330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497602AHEAT TREATMENTSTitaniumSTP 54-200 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497603CHEAT TREATMENTSSurface HardeningSTP 54-010 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497609HEAT TREATMENTSSteelAMS-2759 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522PCD OI-9.0-44 Rev. N/C Submitted under WF ID 46042175330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
041667502AREMAC HEAT TREATING, INC010219,14497614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 330 S 9TH AVECITY OF INDUSTRYCA917463311Bill DuarteQA Manager(626)333-3898
253662076ARNPRIOR AEROSPACES01594,PQA117210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Limited-Alodine 600 conventional only107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498GMPD-032a rev 1-Alodine 600 conventional only107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639APS 026 rev 8107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)QOI 7.5.2.14 rev 5 and QOI 7.5.2 15 rev 2107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117600CHEAT TREATMENTSAluminumProcess Spec C-0521APS 037 rev 12107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117606HEAT TREATMENTSAluminumAMS-2770 107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567QOI 7.5.2.1 rev 17107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)APS 026 rev 8107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
253662076ARNPRIOR AEROSPACES01594,PQA117616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170GMPD-034a Rev 2107 BASKIN DRIVE EASTARNPRIOR, ONTARIO55 Keith BilsonQA Manager 
076905301ASCENT MANUFACTURING, LLC013379240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013Approved Procedure WI-145 Rev. A.2545 W VIA PALMAANAHEIMCA928012624Keith KramerQA Manager(714)540-6414
205472991ASCO AEROSPACE CANADA LTD012516167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 8510 RIVER RDDELTA20V4G 1B5Rachid Arab x223QA Manager(604)946-4900
205472991ASCO AEROSPACE CANADA LTD012516168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 8510 RIVER RDDELTA20V4G 1B5Rachid Arab x223QA Manager(604)946-4900
205472991ASCO AEROSPACE CANADA LTD012516240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 8510 RIVER RDDELTA20V4G 1B5Rachid Arab x223QA Manager(604)946-4900
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD's AAT-Z-001 Rev. M and AAT-Z-002 Rev. U.11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063600BHEAT TREATMENTSAluminumSTP 54-101Approved cleaning procedure AAT-Y-002 Rev. G11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063600CHEAT TREATMENTSAluminumProcess Spec C-0521Approved PCD's AAT-Z-003 AG and AAT-Z-010 R. Approved cleaning procedure AAT-Y-002F.11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063600EHEAT TREATMENTSAluminumLCP73-1039 / P52005No cleaning capabilities prior to heat treat11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
062822952ASTRO ALUMINUM TREATING CO.100026,PQA063606HEAT TREATMENTSAluminumAMS-2770 11040 PALMER AVENUESOUTH GATECA90280Jeff NeerQA Manager(562)923-4344
079467117ATI CAST PRODUCTS SALEM OPERAT100500,02404240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013LMC Touch Up, Revision 04/21/2014.LLC859 7TH ST NWSALEMOR973043806John Benzinger (Quality Supervisor)QA Manager(503)364-3952
607848251ATK SPACE SYSTEMS INC007171,013127134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Based on approval by P. Acres FTW Level 3. Approved procedure TS 10941dated 09/30/14FREEPORT CTR BLDG A15CLEARFIELDUT84016Bryan LovelessQA Manager(801)775-1368
607848251ATK SPACE SYSTEMS INC007171,013127240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 FREEPORT CTR BLDG A15CLEARFIELDUT84016Bryan LovelessQA Manager(801)775-1368
112812177ATLAS TESTING LABORATORIESPQA067162FRACTURE TOUGHNESS TESTINGFracture Toughness TestingASTM-E-399 9820 SIXTH STREETRANCHO CUCAMONGACA91730Sharon NortonQA Manager(909)373-4130
047642319AURORA CASTING and ENGINEERING,005295,23854500ACASTINGSAluminum CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854500DCASTINGSFerrous CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854512ACASTINGSFerrous CastingsSTP53-400 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854512BCASTINGSNon-ferrous CastingsSTP53-400 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness testing only.1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875CLASS D - PH STEELS1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854605CHEAT TREATMENTSSteelFPS-1008, 17-4PH, Type 410 Corrosion Resistant 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
047642319AURORA CASTING and ENGINEERING,005295,23854607HEAT TREATMENTSAluminum CastingsAMS-2771 1790 E LEMONWOOD DRSANTA PAULACA930609510David MartinssonQA Manager(805)933-2761
079981575AVCORP COMPOSITE FABRICATION IS11425802ABONDING AND COMPOSITESBMI Fabrication5PTPLL11 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14822357%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440034%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
079981575AVCORP COMPOSITE FABRICATION IS11425831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
079981575AVCORP COMPOSITE FABRICATION IS11425831BBONDING AND COMPOSITESJSF BMI Fiber Placement2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
079981575AVCORP COMPOSITE FABRICATION IS11425832ABONDING AND COMPOSITESJSF Epoxy Fabrication2ZZP00004 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396622%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
079981575AVCORP COMPOSITE FABRICATION IS11425843BONDING AND COMPOSITESCOMPOSITE FABRICATION FACILITY5PTPPL01 1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
079981575AVCORP COMPOSITE FABRICATION IS11425134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Approved Procedure WI 10-03-18 Rev E.1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
079981575AVCORP COMPOSITE FABRICATION IS11425240APAINT and PRIMEPrime and PaintMIL-F-18264Limted to F-22 and F-35 programs only.1600 W 135TH STGARDENACA902492506Mike TermechiQA Manager(310)970-5323
078846918AVIATION EQUIPMENT PROCESSINGPQA935200LANODIZESulfuric Acid AnodizeSTP 58-208PCD APS 1.005-1 Rev. B1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935200XANODIZEPhosphoric Acid Anodizing of AluminumSTP 58-211 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935818BONDING AND COMPOSITESStructural Adhesive Bonding of Metal AssembliesPS 0120 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405PCD APS 1.003 Rev. G1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PCD APS 1.003 Rev. G1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)PCD APS 4.005 Rev. E1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)PCD APS 4.005 Rev. E1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567PCD APS-C-0567-001 Rev. NC1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935240APAINT and PRIMEPrime and PaintMIL-F-18264 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)PCD APS 5.025-1 Rev. NC1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PCD APS 6.001 Rev. G1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170PCD APS6.001 Rev. G1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
078846918AVIATION EQUIPMENT PROCESSINGPQA935619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCD APS6.001 Rev. G1571 MAC ARTHUR BLVD.COSTA MESACA92626Eric TrainorQA Manager(714)549-0202
074134925B-G DETECTION SERVICEPQA131100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 9235 Glenoaks BlvdSun ValleyCA91352Robert GreeneQA Manager(818)768-8655
074134925B-G DETECTION SERVICEPQA131101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 9235 Glenoaks BlvdSun ValleyCA91352Robert GreeneQA Manager(818)768-8655
074134925B-G DETECTION SERVICEPQA131101BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionP54002 9235 Glenoaks BlvdSun ValleyCA91352Robert GreeneQA Manager(818)768-8655
074134925B-G DETECTION SERVICEPQA131110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 9235 Glenoaks BlvdSun ValleyCA91352Robert GreeneQA Manager(818)768-8655
074134925B-G DETECTION SERVICEPQA131111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 apprpoved source for pre-penetrant etching.9235 Glenoaks BlvdSun ValleyCA91352Robert GreeneQA Manager(818)768-8655
074134925B-G DETECTION SERVICEPQA131111BNON-DESTRUCTIVE TESTINGPenetrant InspectionP54003 9235 Glenoaks BlvdSun ValleyCA91352Robert GreeneQA Manager(818)768-8655
PMSPQA913BAP AEROSPACE DE MEXICOPQA913210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Class 1A, Methods B and C, and Class 3, Method C only.CALLE MAQUILADORA 101 MESA DE OTAYTIJUAN6722444Jesus AnguianoQA Manager(619)400-4175
612706192BARNES GROUP INC.351018300DCHEM MILLING / DESCALINGTitanium Chem MillingFPS-1051Limited to Alpha Case removal only.1025 S DEPOT DROGDENUT844041390JC PondQA Manager(801)917-2011
612706192BARNES GROUP INC.351018602AHEAT TREATMENTSTitaniumSTP 54-200 1025 S DEPOT DROGDENUT844041390JC PondQA Manager(801)917-2011
612706192BARNES GROUP INC.351018240APAINT and PRIMEPrime and PaintMIL-F-18264NO C-130 PAINTING AT THIS FACILITY1025 S DEPOT DROGDENUT844041390JC PondQA Manager(801)917-2011
009688185BARRY AVENUE PLATING CO., INC.S01000,02297200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BTYPES I and IB2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3CLASSES 1A and 32210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101Approved Cleaners: Oakite Lowheat 1 and Oakite 902210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes ZONES 1A, 1B, 1C. Must use QCS-001 source for pre-penetrant etching of titanium and steels.2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297240APAINT and PRIMEPrime and PaintMIL-F-18264 2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297230BPLATINGCadmiumQQ-P-416 Type II 2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
009688185BARRY AVENUE PLATING CO., INC.S01000,02297110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure B.A.P.S. 34, Rev. K.2210 BARRY AVELOS ANGELESCA900641488Laura CurtisQA Manager(310)478-0078
600298764BAZ LtdPQA150200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: Not Approved for F-35Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150200HANODIZEChromic Acid AnodizeSTP 58-209PCD: 01.00 rev 34 and OpS-32-00LM rev C / WF 50848815Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405PCD: 01.00 rev 34, OpS 03.00LM and 33.00LM / WF 50824551Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150600BHEAT TREATMENTSAluminumSTP 54-101 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013Limitation Material 17-7 and 17-4Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150606HEAT TREATMENTSAluminumAMS-2770 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Limitation: Not approved for etching to NDTS-1101, must use approved sourceBar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Approved for STP53-201 not LCP72-108Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150240APAINT and PRIMEPrime and PaintMIL-F-18264 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)PCD: 01.00 rev 34 and 02.00 rev 30 / WF 50848815Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCD: 01.00 rev 34 and 02.00 rev 30 / WF 48528843 (No Local Etch, No Blasting)Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005Limitation: TY II and TY IV only.Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
600298764BAZ LtdPQA150401AWELDINGFusion WeldingSTP 55-104 Bar-Lev Industrial ParkMobile Post Misgav 20179Meir HazanQA Manager(972)495-6900
SAPPQA925BEAGLE TGPQA925210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405PCD Lock001, issue 5 / WF 49975491STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925600BHEAT TREATMENTSAluminumSTP 54-101 STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925606HEAT TREATMENTSAluminumAMS-2770 STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)PCD Lock004, issue 7 Aluminum alloys onlySTONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCD-0102/0103, rev. issue 8STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925401AWELDINGFusion WeldingSTP 55-104 STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
SAPPQA925BEAGLE TGPQA925404CWELDINGResistance WeldingSTP 55-005 STONY LACHRISTCHURCH, BH23 1EX GB  Steve ForsterQA Manager(120)248-2296
019900399BODYCOTE - ARLINGTON012977,PQAB01160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 428 DODSON LAKE DRIVEARLINGTONTX76012Eric ReasonQuality Engineer 
019900399BODYCOTE - ARLINGTON012977,PQAB01169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 428 DODSON LAKE DRIVEARLINGTONTX76012Eric ReasonQuality Engineer 
019900399BODYCOTE - ARLINGTON012977,PQAB01601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSIExtended quench delay approved by Ken Sabo.428 DODSON LAKE DRIVEARLINGTONTX76012Eric ReasonQuality Engineer 
019900399BODYCOTE - ARLINGTON012977,PQAB01604HEAT TREATMENTSD6AC SteelFPS-1029 428 DODSON LAKE DRIVEARLINGTONTX76012Eric ReasonQuality Engineer 
019900399BODYCOTE - ARLINGTON012977,PQAB01609HEAT TREATMENTSSteelAMS-2759 428 DODSON LAKE DRIVEARLINGTONTX76012Eric ReasonQuality Engineer 
019900399BODYCOTE - ARLINGTON012977,PQAB01609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 428 DODSON LAKE DRIVEARLINGTONTX76012Eric ReasonQuality Engineer 
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002426ABRAZINGBrazingSTP 55-303 515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002427BBRAZINGFurnace BrazingProcess Spec C-1426 / 1426Excludes C-1426. PS 1426 approval only.515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009Excludes aluminum.515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness testing only.515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002602CHEAT TREATMENTSTitaniumLCP 73-1026 515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002602EHEAT TREATMENTSTitaniumAMS-2801 515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
PMSPQA391BODYCOTE THERMAL PROCESSINGPQA391603CHEAT TREATMENTSSurface HardeningSTP 54-010BMS-WI 09.11.014208 SOUTH 74TH EAST AVENUETULSAOK74145Pam ScottQA Manager(918)627-7324
PMSPQA391BODYCOTE THERMAL PROCESSINGPQA391609HEAT TREATMENTSSteelAMS-2759 4208 SOUTH 74TH EAST AVENUETULSAOK74145Pam ScottQA Manager(918)627-7324
PMSPQA391BODYCOTE THERMAL PROCESSINGPQA391609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 4208 SOUTH 74TH EAST AVENUETULSAOK74145Pam ScottQA Manager(918)627-7324
PMSPQA391BODYCOTE THERMAL PROCESSINGPQA391610HEAT TREATMENTSCopper Berrylium Heat TreatMIL-H-7199 4208 SOUTH 74TH EAST AVENUETULSAOK74145Pam ScottQA Manager(918)627-7324
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002611HEAT TREATMENTSWROUGHT NICKEL and COBALT ALLOY PARTS (INCONEL)AMS 2774 515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
008264673BODYCOTE THERMAL PROCESSINGR16002,PQA133,16002614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 515 W APRA STREETCOMPTONCA90220Martha SierotaQA Manager(310)604-8000
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088)PROCESS CODE CHANGED TO AMS27727474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037600BHEAT TREATMENTSAluminumSTP 54-101 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037600EHEAT TREATMENTSAluminumLCP73-1039 / P52005 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
029169682BODYCOTE THERMAL PROCESSING - WESTMINSTERPQA037606HEAT TREATMENTSAluminumAMS-2770 7474 GARDEN GROVE BLVD. PLANT #1WESTMINSTERCA926832298Marcia BellQA Manager(714)893-6561
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved on WF ID 395202644008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013No A286 to be processed at this facility4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797604AHEAT TREATMENTSD6AC SteelFPS-1029, Endothermic Direct Quench 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797604GHEAT TREATMENTSD6AC SteelFPS-1029, Vacuum Direct Quench 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797605AHEAT TREATMENTSSteelFPS-3014No solution heat treat to FPS-3014 requirements.4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797605AHEAT TREATMENTSSteelFPS-3014No solution heat treat to FPS-3014 requirements.4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797609BHEAT TREATMENTSSteel - Low Alloy GT220 ksiAMS 2759/2 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797609BHEAT TREATMENTSSteel - Low Alloy GT220 ksiAMS 2759/2 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
SAPS11797BODYCOTE THERMAL PROCESSING, IS11797611HEAT TREATMENTSWROUGHT NICKEL and COBALT ALLOY PARTS (INCONEL)AMS 2774Age only4008 CLAY AVEHALTOM CITYTX761171717Tony MarshQA Manager 
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Steel alloys only1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)approved PCD 2/2/2015 QS 7.5.1.61009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Steel alloys only approved PCD QS 8.2.4.1.11019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539600BHEAT TREATMENTSAluminumSTP 54-101 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539600CHEAT TREATMENTSAluminumProcess Spec C-0521QS 7.5.1.3 rev 11009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
121765135BODYCOTE THERMAL PROCESSING, INC.PQA539606HEAT TREATMENTSAluminumAMS-2770 1009 S. WEST STREETWICHITAKS67213Owen MclainQA Manager(316)943-3288
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538609HEAT TREATMENTSSteelAMS-2759 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538609BHEAT TREATMENTSSteel - Low Alloy GT220 ksiAMS 2759/2 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538609EHEAT TREATMENTSSTEEL - MARTENSITIC CRESAMS 2759/5 1019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
147468375BODYCOTE THERMAL PROCESSING, INC.PQA538613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522approved PCD QI 8.2.4.3.11019 S. MCLEAN BLVD.WICHITAKS672134598Mark AffolterQA Manager(316)267-6264
062943712BODYCOTE, CAMASPQA389602HEAT TREATMENTSTitaniumAMS-H-81200Vacuum furnace maximum length is 72 inch . Approval limited to Hot Isostatic Press (HIP) only.4605 NORTHWEST PACIFIC RIMCAMASWA98607Kelly KeggQA Manager(360)833-1120
879182327BODYCOTE, SANTA FE SPRINGSS00363,PQA397,10608168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 9921 ROMANDELSANTA FE SPRINGCA90670Joel CatapQA Manager(562)946-1717
879182327BODYCOTE, SANTA FE SPRINGSS00363,PQA397,10608601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875LTD TO RAW FORGINGS WITH 0.020 inch MATERAIL REMOVAL PER SURFACE9921 ROMANDELSANTA FE SPRINGCA90670Joel CatapQA Manager(562)946-1717
879182327BODYCOTE, SANTA FE SPRINGSS00363,PQA397,10608602HEAT TREATMENTSTitaniumAMS-H-81200EXCEPT TI-6AL-4V and TI-6AL-4V ELI MATERIALS WHEN WATER QUENCH IS REQUIRED9921 ROMANDELSANTA FE SPRINGCA90670Joel CatapQA Manager(562)946-1717
008258626BODYCOTE, VERNONPQA112160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness testing only.2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness testing only. Approved PCD ADE-NA-GDOC-VERNON-12, N/A.2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112604HEAT TREATMENTSD6AC SteelFPS-1029 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112604AHEAT TREATMENTSD6AC SteelFPS-1029, Endothermic Direct Quench 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112605AHEAT TREATMENTSSteelFPS-3014 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112609HEAT TREATMENTSSteelAMS-2759 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522Approved PCD BMS-D72 WI C-0522, 01/18/2010. Approved cleaning PCD - ADE-NA-GDOC-VERNON-001, rev. N/A.2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008258626BODYCOTE, VERNONPQA112614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 2900 S. SUNOL DR.VERNONCA90023Dr. Dmytro ZagrebelnyyQA Manager(323)264-0111
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BTank Size - 21' Length x 2.3' Width x 8' Depth.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200CANODIZEHard AnodizeMIL-A-8625, Type III 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200HANODIZEChromic Acid AnodizeSTP 58-209Excludes Type IA.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200IANODIZEChromic Acid AnodizeProcess Spec C-0494 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200JANODIZEChromic Acid AnodizeLCP77-2038/LADC-P-77-2038 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD BPS-705 Supp. 6 Rev. F. Excludes dyed coatings.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200MANODIZESulfuric Acid AnodizeProcess Spec C-0494 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200NANODIZESulfuric Acid AnodizeLCP77-2037/LADC-P-77-2037 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200OANODIZEHard AnodizeSTP 58-206 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200PANODIZEHard AnodizeProcess Spec C-0445 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200P1ANODIZEHard AnodizePS0445 Hard Anodizing of Aluminum Alloys 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB. Approved Paint Stripping Procedure BPS-720 Rev. M Section 7.9.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634205ACHEMICAL CONVERSION COATINGTitanium Fluoride-Phosphate Coating5PTPHG16Approved Procedure BPS-739 Rev. F Supp. 1. Re-qualification completed by Ft. Worth M and P on Talon Tag H131948 10-10-2016.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634206CHEMICAL CONVERSION COATINGTitanium Conversion CoatingAMS-2486 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD BPS-703 Supp. 1 Rev. J.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD BPS-703 Supp. 1 Rev. J.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634210CCHEMICAL CONVERSION COATINGChem FilmP56011Type I only.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016Approved Procedure BPS-739 Supp. 1 Rev. E.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD BPS 721 Supp. 3 Rev. A.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD BPS-716 Rev. L.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634609HEAT TREATMENTSSteelAMS-2759 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008Limited to Baking Only (Embrittlement Relief), No Stress Relieving.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD BPS-753 Rev. A. Limited to Baking Only, No Stress Relief. Limited to under 220 ksi.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634101BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionP54002 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Includes Zones 1A, 1B and 1C. See FWQPL for Approved Materials.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedures BPS-715 Rev. AI and BPS-715 Supp. 4 Rev. A.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedures BPS-715 Supp. 4 Rev. A.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedures BPS-715 Supp. 4 Rev. A.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes castings. No Level 2 sensitivity penetrant.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634111BNON-DESTRUCTIVE TESTINGPenetrant InspectionP54003 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD's BPS-715 Rev. AI and BPS-715 Supp. 5 Rev. A. Excludes castings.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD BPS-715 Rev. AI and BPS-715 Supp. 4 Rev. A.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, F-35 Facility Re-qualification Due September 30, 2017.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Approved for Non-Critical and Critical Parts. Approved Procedure BPS-715 Supp. 4 Rev. A.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634240APAINT and PRIMEPrime and PaintMIL-F-18264 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)Approved PCD BPS-720 Supp. 3 Rev. D.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634248PAINT and PRIMETouch-Up Requirements for Finishes On P-3C-395-M (Effective 01-01-2014) 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634239CPHOSPHATEPhospateSTP 58-302No pre-phosphate stress relief capabilities. Must utilize a capable/approved source, as applicable. Excludes Class 4.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634239DPHOSPHATEPhosphateMIL-DTL-16232, Type Z or M, Class 1,3 (Class 2 effective 01-01-2014)Approvals for Type M Class 1, 2 and 3 Only.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634230APLATINGCadmiumQQ-P-416 Type I 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634230BPLATINGCadmiumQQ-P-416 Type II 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634230HPLATINGCadmiumSTP 58-001 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634230IPLATINGCadmiumLCP77-1061/LADC-P-77-1061Not approved for Aluminum, CRES, Nickel or Depleted Uranium.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634230JPLATINGCadmium (P3 ONLY)C-0491Approved PCD BPS-708 Supp. 1 Rev. B, Excludes Type III.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure BPS-701 Supp. 1 Rev. L.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634110C2PRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure BPS-701 Supp. 1 Rev. L.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634146B1PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGG01Approved Procedure BPS-701 Supp. 1 Rev. K.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634146B2PRE-PENETRANT ETCHPre-Penetrant Etch - Titanium5PTPGG01Approved Procedure BPS-701 Supp. 1 Rev. K.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved Procedure BPS-701 Supp. 1 Rev. L.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001Approved Procedure BPS-701 Supp. 1 Rev. L.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD BPS-748 Rev. D for Aluminum, Steel, CRES and Titanium Alloys and Approved PCD BPS-752 Rev. B for Copper Alloys.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD BPS-748 Rev. D for Aluminum, Steel, CRES and Titanium Alloys and Approved PCD BPS-752 Rev. B for Copper Alloys.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101Approved PCD BPS-741 Supp. 2 Rev. C.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD BPS-749 Rev. C.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634620PRE-PENETRANT ETCHTitanium Alloys-Alkaline/Acid Metal Remova MethodsSTP57-401Approved Procedure BPS-701 HSE Supp. 1 Rev. B.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634621PRE-PENETRANT ETCHCopper Alloys (Alkaline/Acid Methods Only)STP57-701Approved PCD BPS-752 Rev. B.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634250ASOLID FILM LUBRICANTSSolid Film Lubricant - Solvent BaseFPS-3006 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614032%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Approved Applicators: Jose Martinez and Elias Cortez. Not Approved for Class VIII.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
008475964BOWMAN PLATING COMPANY, INC.004998,PQA132,00634252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005Excludes Types III and VI.2631 E. 126TH ST. PO BOX 3105COMPTONCA90222Blanca HuertaQA Manager(310)639-4343
PMSPQA259BRADDOCK METALLURGICALPQA259168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259609HEAT TREATMENTSSteelAMS-2759 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259611HEAT TREATMENTSWROUGHT NICKEL and COBALT ALLOY PARTS (INCONEL)AMS 2774 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
PMSPQA259BRADDOCK METALLURGICALPQA259614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 400 FENTRESS BLVD.DAYTONA BEACHFL32114Cindy RobinsonQA Manager(386)323-1500
050098607BURBANK STEEL TREATINGS01197,PQA160,03286160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Excludes conductivity testing.415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD WI-4, Revision J.415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013Approval EXCLUDES finish machined parts. Approved cleaning PCD WI-11, revision D.415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286601JHEAT TREATMENTSCorrosion Resistant SteelsLCP73-2018/LADC-P-73-2018 HT 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286602HEAT TREATMENTSTitaniumAMS-H-81200 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286602EHEAT TREATMENTSTitaniumAMS-2801 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286603AHEAT TREATMENTSCarburizingMIL-S-6090 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286605AHEAT TREATMENTSSteelFPS-3014 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286609HEAT TREATMENTSSteelAMS-2759 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286609BHEAT TREATMENTSSteel - Low Alloy GT220 ksiAMS 2759/2 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286609EHEAT TREATMENTSSTEEL - MARTENSITIC CRESAMS 2759/5 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286609GHEAT TREATMENTSSteel - CarburizingAMS 2759/7 415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522Approved PCD WI-1, revision K. Approved cleaning PCD WI-11, revision D.415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008Approved cleaning PCD WI-11, Revision D.415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
050098607BURBANK STEEL TREATINGS01197,PQA160,03286622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD WI-1, revision K. Approved cleaning PCD WI-11, D.415 S. VARNEY ST.BURBANKCA915022125Oscar OsornioQA Manager(818)842-0975
065946642BURTON INDUSTRIESPQA161160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)QAD 050 and QAD 060 / WF ID 36849955243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161600BHEAT TREATMENTSAluminumSTP 54-101 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161601BHEAT TREATMENTSSteelSTP 54-006, Above 220 KSI 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161601BHEAT TREATMENTSSteelSTP 54-006, Above 220 KSI 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161605AHEAT TREATMENTSSteelFPS-3014 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161606HEAT TREATMENTSAluminumAMS-2770 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161609HEAT TREATMENTSSteelAMS-2759 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161609BHEAT TREATMENTSSteel - Low Alloy GT220 ksiAMS 2759/2 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
065946642BURTON INDUSTRIESPQA161613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522QAD 370 / WF ID 36849842243 WYANDANCH AVE.N. BABYLONNY11704Dariusz Siniakowicz (x145 or x160)QA Manager(631)643-6660
155548076CALIDAD, INC.010165512BCASTINGSNon-ferrous CastingsSTP53-400Aluminum Investment Castings Only.1730 S BALBOA AVEONTARIOCA917617773Rito GarciaQA Manager(909)947-3937
005522883CALIFORNIA AMFORGE CORPORATION809364514FORGINGSForgingLMA-PA041Excludes aluminum.750 N VERNON AVEAZUSACA917022231Simone SutherlandQA Manager(626)334-4931
141453923CALIFORNIA DROP FORGE, INC.340077510AFORGINGSAluminum ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077510BFORGINGSSteel ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077510CFORGINGSTitanium ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077510DFORGINGSCRES ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077511FORGINGSForgings5PTPAG41 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14620938%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440034%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Approved PCD DIE 0654, revision N/C.1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562Approved PCD DIE 1164, revision A.1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
141453923CALIFORNIA DROP FORGE, INC.340077111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068STP53-201 APPROVAL ONLY.1033 ALHAMBRA AVELOS ANGELESCA900122929Minh TangQA Manager(323)221-1134
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD CMP-43 Rev. B.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PCD CMP 5LMA-N/CP.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PCD CMP 5LMA-N/CP.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182609HEAT TREATMENTSSteelAMS-2759 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008Approved for Stress Relieving and Baking only, No cold steel treatment.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD CMP-36 Rev. G.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101Approved cleaner: Brulin 815 GD only.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes LCP72-1068.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD CMP-1LMA Rev. A.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182150ANON-DESTRUCTIVE TESTINGNital Etch InspectionNDTS-9111 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182150DNON-DESTRUCTIVE TESTINGEtch Inspection of High Strength Steel PartsSTP 53-701Approved PCD CMP-26STP Rev. A.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182240APAINT and PRIMEPrime and PaintMIL-F-18264 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)CMP -17-LM Rev AP.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182248PAINT and PRIMETouch-Up Requirements for Finishes On P-3C-395-M (Effective 01-01-2014)CMP -17-LM Rev AP.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182230APLATINGCadmiumQQ-P-416 Type I P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182230BPLATINGCadmiumQQ-P-416 Type II P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182230GPLATINGCadmiumFPS-1007, Grade B Type II P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182230JPLATINGCadmium (P3 ONLY)C-0491Approved PCD CMP-4LM Rev. A. Excludes Type III. Approval Excludes Aluminum and Uranium.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182230MPLATINGCadmium (C-130 ONLY)Process Spec 0491Approval Excludes Type III. Approval Excludes Aluminum.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182234APLATINGElectroless NickelMIL-C-26074, Class 1 / (AMS 2404 Class 1 effective 01-01-2014)Low phosphoruous only per AMS 2404.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182234BPLATINGElectroless NickelMIL-C-26074, Class 2 (AMS 2404 Class 2 effective 01-01-2014)Low phosphoruous only per AMS 2404.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure CMP-33 Rev. G.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD CMP-40 Rev. NC. Approved for Aluminum Etch Only. Approved for cleaning of all materials.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD CMP-40 Rev. NC. Approved for Aluminum Etch Only. Approved for cleaning of all materials.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD CMP-41 Rev. A.P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
043083971CALIFORNIA METAL PROCESSINGS10364,PQA182251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 P.O BOX 4859PALOS VERDESCA90274Richard StromerQA Manager(323)753-2247
004465142CANTON DROP FORGEPQA178513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 4575 SOUTHWAY STREET SWCANTONOH44706Dan AntosQA Manager(330)477-4511
004465142CANTON DROP FORGEPQA178601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 4575 SOUTHWAY STREET SWCANTONOH44706Dan AntosQA Manager(330)477-4511
004465142CANTON DROP FORGEPQA178100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444inch Inspection of forged parts in as-forged condition only, no machined part final magnetic particle inspection allowed inch .4575 SOUTHWAY STREET SWCANTONOH44706Dan AntosQA Manager(330)477-4511
004465142CANTON DROP FORGEPQA178101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001inch Inspection of forged parts in as-forged condition only, no machined part final magnetic particle inspection allowed inch .4575 SOUTHWAY STREET SWCANTONOH44706Dan AntosQA Manager(330)477-4511
147471494CAPPS MANUFACTURING009941,PQA189210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405W.I 1.4.3.2, 7-16-2014 class 12121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498W.I 1.4.3.2, 7-16-2014 class 12121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)WI-1.10-4-26-20102121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189600BHEAT TREATMENTSAluminumSTP 54-101 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189600CHEAT TREATMENTSAluminumProcess Spec C-0521WI-1-1.9.9.b2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189606HEAT TREATMENTSAluminumAMS-2770 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567W.I 1.4.8.17, 7-23-20142121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)w.i.1.4.6.8, 7-23-20142121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 2121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170W.I 1.4.2.2,rev 12121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
147471494CAPPS MANUFACTURING009941,PQA189619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301W.I 1.4.2.2,rev 12121 S. EDWARDSWICHITAKS67213Claude HephnerQA Manager(316)942-9351
006251615CARLEY FOUNDRY, INC.009540512BCASTINGSNon-ferrous CastingsSTP53-400 8301 CORAL SEA ST NEBLAINEMN554497252Dan SchwarzQA Manager(763)205-8921
006251615CARLEY FOUNDRY, INC.009540169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)For hardness/ tensile testing of aluminum castings only.8301 CORAL SEA ST NEBLAINEMN554497252Dan SchwarzQA Manager(763)205-8921
006251615CARLEY FOUNDRY, INC.009540607HEAT TREATMENTSAluminum CastingsAMS-2771 8301 CORAL SEA ST NEBLAINEMN554497252Dan SchwarzQA Manager(763)205-8921
006251615CARLEY FOUNDRY, INC.009540111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must utilize QCS-001 source for pre-penetrant etching8301 CORAL SEA ST NEBLAINEMN554497252Dan SchwarzQA Manager(763)205-8921
006251615CARLEY FOUNDRY, INC.009540121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Casting X-ray.8301 CORAL SEA ST NEBLAINEMN554497252Dan SchwarzQA Manager(763)205-8921
006251615CARLEY FOUNDRY, INC.009540406GWELDINGWeld Repair of CastingsSTP-55-801 8301 CORAL SEA ST NEBLAINEMN554497252Dan SchwarzQA Manager(763)205-8921
197305493CASCADE ENGINEERING TECHNOLOGI012302240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013Procedure Touchup of Lockheed Martin Products Rev. 4.INC.14707 SE RIVER RDMILWAUKIEOR972672601Corey BarekstenQA Manager(503)653-7999
208502393CENTRA INDUSTRIES INC012512167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009Added based on requested SSM Survey and acceptable corrective action24 CHERRY BLOSSOM RDCAMBRIDGE20N3H 4R7Calum MacKellarQA Manager(519)650-2828
208502393CENTRA INDUSTRIES INC012512168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009Added based on requested SSM Survey and acceptable corrective action24 CHERRY BLOSSOM RDCAMBRIDGE20N3H 4R7Calum MacKellarQA Manager(519)650-2828
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225607HEAT TREATMENTSAluminum CastingsAMS-2771 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Procedure CTQA01, Rev L (8/29/03)5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved for Non-Critical Parts and Critical Parts. Not Approved For Fracture Critical Procedure CTQA01 Rev New (07/25/2006)5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742APPROVED FILM READERS: T.RILEY, D.ROHRBACH, AND D. IMMELL5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301CTQA02 Rev I 7/7/20115801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301 5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure CTQA01.1LFWC, Rev C (11/9/02)5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Aluminum Only per procedure CTQA01.1LFWC, Rev C (11/9/02)5801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
144952694CENTRAL TEXAS HEAT TREAT186573,PQA225619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Procedure approved on WF ID -366599115801 DENTON HWY (F-50M)HALTOM CITYTX76148David RohrbachQA Manager(817)788-8511
047782222CERTIFIED METAL CRAFTPQA191160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191600BHEAT TREATMENTSAluminumSTP 54-101 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSIApproved PCD PM018 Rev. 031877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191602HEAT TREATMENTSTitaniumAMS-H-81200 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191602EHEAT TREATMENTSTitaniumAMS-2801 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191605AHEAT TREATMENTSSteelFPS-3014 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191606HEAT TREATMENTSAluminumAMS-2770 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191607HEAT TREATMENTSAluminum CastingsAMS-2771 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191609HEAT TREATMENTSSteelAMS-2759 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
047782222CERTIFIED METAL CRAFTPQA191609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 877 VERNON WAYEL CAJONCA92020Dale PontowQA Manager(619)593-3636
079153486CHANDLER INDUSTRIES, INC.S11439167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 260 PLYMOUTH AVE NMINNEAPOLISMN554113437Chris Moore x-172Quality Engineer(612)339-8261
079153486CHANDLER INDUSTRIES, INC.S11439168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 260 PLYMOUTH AVE NMINNEAPOLISMN554113437Chris Moore x-172Quality Engineer(612)339-8261
079153486CHANDLER INDUSTRIES, INC.S11439240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 260 PLYMOUTH AVE NMINNEAPOLISMN554113437Chris Moore x-172Quality Engineer(612)339-8261
201244555CHICOPEE MANUFACTURING LIMITED010143,02533240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013MAK-PP-41 Rev G-2975 WILSON AVEKITCHENER20N2C 1J1Paul BlackfordQA Manager 
188198998CLEARWATER ENGINEERING, INC.013235167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 301 N RIVER STDERBYKS670371528Jerry MorrisQA Manager(316)425-0202
188198998CLEARWATER ENGINEERING, INC.013235168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 301 N RIVER STDERBYKS670371528Jerry MorrisQA Manager(316)425-0202
188198998CLEARWATER ENGINEERING, INC.013235240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 301 N RIVER STDERBYKS670371528Jerry MorrisQA Manager(316)425-0202
045548484COAST HEAT TREATING CO.PQA204169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved for Hardness Testing Only.1767 INDUSTRIAL WAYLOS ANGELESCA90023Luis Antonio CastanedaQA Manager(323)263-6944
045548484COAST HEAT TREATING CO.PQA204170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD Q. P. 4.10C Rev. B Amd. 4. Approved for Hardness Testing Only.1767 INDUSTRIAL WAYLOS ANGELESCA90023Luis Antonio CastanedaQA Manager(323)263-6944
045548484COAST HEAT TREATING CO.PQA204607HEAT TREATMENTSAluminum CastingsAMS-2771Aluminum Castings Only1767 INDUSTRIAL WAYLOS ANGELESCA90023Luis Antonio CastanedaQA Manager(323)263-6944
009588278COAST PLATINGPQA205,02708200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BExcludes Type 1C.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708200CANODIZEHard AnodizeMIL-A-8625, Type III 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD CPP-2 Rev. V. Non-dyed only.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708200SANODIZEChromic Acid Anodize2ZZP00001 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD CPP 7-5 Rev. D. Limited to Class 1 only.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD CPP 7-5 Rev. D.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725No Type 3 Coatings Applied.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD CPP-15 Rev. D.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Must use QCS-001 source for pre-penetrant etch for steel and titanium. Excludes Zones 1A, 1B and 1C.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD CPP-6 Rev. AK.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD CPP-6 Rev. AK.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 12-31-2017. Approved for Aluminum Processing Only.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708240APAINT and PRIMEPrime and PaintMIL-F-18264 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD CPP-10-1 Rev. M.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved PCD CPP 10-5 Rev. A. Limited to processing Aluminum alloys.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD CPP-10-1 Rev. M (Aluminum) and CPP-10-3 Rev. I (Titanium). Not approved for CRES or Steel alloys.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD CPP-10-1 Rev. M (Aluminum) and CPP-10-3 Rev. I (Titanium). Not approved for CRES or Steel alloys.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD CPP-10-1 Rev. M.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
009588278COAST PLATINGPQA205,02708620PRE-PENETRANT ETCHTitanium Alloys-Alkaline/Acid Metal Remova MethodsSTP57-401Approved PCD CPP-10-3 Rev. I.128 W. 154TH ST.GARDENACA90247Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BTank Size 324 inch Length x 48 inch Width x 96 inch Depth.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932200CANODIZEHard AnodizeMIL-A-8625, Type III 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932200LANODIZESulfuric Acid AnodizeSTP 58-208 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932200SANODIZEChromic Acid Anodize2ZZP00001 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD CPP-2C Rev. A.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD CPP-7-5C Rev. A.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725No Type 3 Coatings Applied.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD CPP-15C Rev. A.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068No approved for Castings, Excludes LCP72-1068.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD CPP-6C Rev. C.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD CPP-6C Rev. C.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification Approval Expires 4-30-2019. Approved for Aluminum Processing Only.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932240APAINT and PRIMEPrime and PaintMIL-F-18264 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)Approved PCD CPP-16C Rev. B.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD CPP-10-1C Rev. A.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved PCD CPP-10-5C Rev. E, Not approved for Castings.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD CPP-10-1C Rev. A, Approved for Aluminum Only.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD CPP-10-1C Rev. A, Approved for Aluminum Only.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD CPP-10-1C Rev. A.417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
SAPPQA932COAST PLATING (Carson)PQA932251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 417 W. 164TH STREETGARDENACA90248Eric StollQA Manager(310)366-5972
933989386COATING TECHNOLOGYPQA206200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206200LANODIZESulfuric Acid AnodizeSTP 58-208CT-20-IIA Supplement Rev B360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approval limited to Class 1,conventional/special etch. CT-30-I Rev B per WF42730999360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206240APAINT and PRIMEPrime and PaintMIL-F-18264 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
933989386COATING TECHNOLOGYPQA206247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 360 SCARLET BLVD.OLDSMARFL34677J. D RennerQA Manager(813)854-3674
108886169CONNELL PROCESSING, INC.002898,04477,04477200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD P402 Rev. N/C, amendment number 1. Excludes Dyed Coatings.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477200MANODIZESulfuric Acid AnodizeProcess Spec C-0494Limited to Type II only.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477200NANODIZESulfuric Acid AnodizeLCP77-2037/LADC-P-77-2037Excludes Grade B Seal and Class 2 Dyed Coating.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477206CHEMICAL CONVERSION COATINGTitanium Conversion CoatingAMS-2486 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Includes Type II.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD P361 Rev. A.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD P301G, Variance 7.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477210CCHEMICAL CONVERSION COATINGChem FilmP56011TYPE I ONLY3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725Type 2 ONLY.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD P602 Rev. A.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD P700 Rev. N/C.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477111BNON-DESTRUCTIVE TESTINGPenetrant InspectionP54003 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD Approved PCD P108 Rev. N/C3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477240APAINT and PRIMEPrime and PaintMIL-F-18264Not approved for LMA-PJ013 or LMA-PJ264.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)Approved PCD P601 Rev. N/C.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014)Excludes MIL-P-23377 material.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure P-210 Rev. H, and Variance number 13080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCDs P206 Rev. B, amend. 1 for AL, P221 Rev. N/C for CRES, P231 Rev. A, amend. 1 for Ti, and P251 Rev. A for Steels.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCDs P206 Rev. B, amend. 1 for AL, P221 Rev. N/C for CRES, P231 Rev. A, amend. 1 for Ti, and P251 Rev. A for Steels.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101Approved PCD P221 Rev. A, amend. 13080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477618PRE-PENETRANT ETCHCarbon Steels (Alkaline/Acid Methods Only)STP57-201Approved PCD P251 Rev. A, amend. 1.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD P206 Rev. B, amend. 13080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477620PRE-PENETRANT ETCHTitanium Alloys-Alkaline/Acid Metal Remova MethodsSTP57-401Approved PCD P231 Rev. A, amend. 13080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477621PRE-PENETRANT ETCHCopper Alloys (Alkaline/Acid Methods Only)STP57-701Approved PCD P241 Rev. A, amend. 1.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005TYPES II, III, IV, V, and VII3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
108886169CONNELL PROCESSING, INC.002898,04477,04477253SOLID FILM LUBRICANTSSolid Film LubricantsP62001 (supersedes LADC-P-81-2064)Not Approved for Type VI.3080 N. AVON ST.BURBANKCA91504Stephen LeeQA Manager(818)845-7661
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605512BCASTINGSNon-ferrous CastingsSTP53-400Approved PCD 480556-991 (P-3 Program, AV01).8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness Testing Only.8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD number WIP SP 2.0, revision U. Hardness Testing Only.8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417P-3 Certified Parts Program. Do not inactivate for lack of activity.8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 listed source for pre-penetrant etchning.8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD SP 4.0, rev. X. Must use QCS-001 approved source for pre-penetrant etching. P-3 Certified Parts Program. Do not inactivate for lack of activity.8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
008483406CONSOLIDATED FOUNDRIES/P.A.C. INDUSTRIES08605121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved Procedure WIP SP 5.0 Rev.T.8333 WILCOX AVENUECUDAHYCA902215309Frank RangelQA Manager 
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562PCD Approved on WF44025752 Includes LAC0562V01677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562PCD Approved on WF44025752 Includes LAC0562V01677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) 677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Limited to level 2 sensitivity677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
058864125CONSOLIDATED INDUSTRIES, INC.101201,223521111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Limited to level 2 sensitivity and Forgings677 MIXVILLE RDCHESHIRECT064103800Tim McHenry extQA Manager(203)272-5371
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549500ACASTINGSAluminum CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936500ACASTINGSAluminum CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549500DCASTINGSFerrous CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238500DCASTINGSFerrous CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
829422513CONSOLIDATED PRECISION PRODUCT005270,03238512ACASTINGSFerrous CastingsSTP53-400 CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549512ACASTINGSFerrous CastingsSTP53-400Must use QCS-001 source for all repair welding of castings. P-3 Program PCD submitted on WF number 54690092.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549512BCASTINGSNon-ferrous CastingsSTP53-400Must use QCS-001 source for all repair welding of castings. P-3 Program PCD submitted on WF number 54690092.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Excludes ConductivityCORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD 1130, revision Z. Hardness testing only.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875CLASS D MATERIAL ONLY, (17-4 PH)CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875Class C and D materials only.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238605AHEAT TREATMENTSSteelFPS-301417-4 PH ONLYCORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549605CHEAT TREATMENTSSteelFPS-1008, 17-4PH, Type 410 Corrosion ResistantApproved for 17-4 PH material only. Excludes 410 material.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238605CHEAT TREATMENTSSteelFPS-1008, 17-4PH, Type 410 Corrosion Resistant17-4 PH ONLYCORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936607HEAT TREATMENTSAluminum CastingsAMS-2771 4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549607HEAT TREATMENTSAluminum CastingsAMS-2771 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Luis Rodriguez PT Level 3.4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C.4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zoens 1A, 1B, and 1C. Must use QCS-001 Source for Pre-Penetrant Etching.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C. Must utilize QCS-001 source for pre-penetrant etchingCORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes LCP72-1068. Must use QCS-001 Approved Source for Pre-Penetrant Etching.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD 6-3-C, revision AN. Must use QCS-001 listed source for pre-penetrant etching.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02Must use QCS-001 Source for Pre-Penetrant Etching.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742Gabriel Reyes RT Level 3. Approved Readers: J Hennagan, R. Marroquin, and D. Avila.4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
829422513CONSOLIDATED PRECISION PRODUCT005270,03238120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
829422513CONSOLIDATED PRECISION PRODUCT005270,03238120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved PCD 6-4-B, Revision AA. Approved Digital Radiography PCD 6-7-B, Rev. A.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549122ANON-DESTRUCTIVE TESTINGX-Ray5PTPCL06 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD: CSP-6604A Rev. K and CSP-6615 Rev.K4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549405AWELDINGWeld Repair of CastingsFPS-1082 - AluminumApproved welders Luis Rodriguez, Martin Gonzalez and Charles Rockett.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
SAPPQA936CONSOLIDATED PRECISION PRODUCTPQA936405AWELDINGWeld Repair of CastingsFPS-1082 - AluminumApproved Welders: L. Andino, V. Martinez and E. Sanchez.4200 W. VALLEY BLVD.POMONACA91769Bhargav VyasQA Manager(909)839-2233
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549405BWELDINGWeld Repair of CastingsFPS-1082 - PH SteelQualified welders Daniel Amaro, Charles Rockett and Luis Rodriguez only.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238405BWELDINGWeld Repair of CastingsFPS-1082 - PH SteelSimon Lieu approved for Inconel casting weld repair by JT Amin 11/19/2003CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549406GWELDINGWeld Repair of CastingsSTP-55-801Aproved welder for aluminum Martin Gonzalez, Luis Rodriguez and Charles Rockett. Approved welders Charles Rockett and Daniel Amaro for steel castings.INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
828304977CONSOLIDATED PRECISION PRODUCT719953,720051,07549409WELDINGWeld Repair of CastingsAMS-2694 INC705 INDUSTRIAL WAYPORT HUENEMECA930413505Luis Herrera (X-4369)QA Manager(805)488-4651
829422513CONSOLIDATED PRECISION PRODUCT005270,03238409WELDINGWeld Repair of CastingsAMS-2694 CORP.16800 CHESTNUT STCITY OF INDUSTRYCA917481017Karen Beck-AshleyQA Manager(626)937-3404
050103225CONTINENTAL FORGE COMPANY226432,19283510AFORGINGSAluminum ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.ALUMINUM ONLY412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562 412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283517FORGINGSAlum Alloy ForgingsSTM05-101ALUMINUM ONLY412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD: WI-09-07 Rev. G (WF ID 45124683)412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.W1-09-06 Rev. F (WF ID 44372998)412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)WI-09-06 Rev. F (WF ID 42631000). Aluminum forgings only412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
050103225CONTINENTAL FORGE COMPANY226432,19283616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170WI-09-06 Rev. F (WF ID 42631000). Aluminum forgings only412 E EL SEGUNDO BLVDCOMPTONCA902222317Jose MuroQA Manager(310)603-1014
180002925CONTINENTAL HEAT TREATINGPQA215160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness testing only.10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Excludes aluminum. Approved PCD W4.18.13 Rev. N10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215601A1HEAT TREATMENTSSteelLCP73-2020/LADC-P-73-2020 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215601JHEAT TREATMENTSCorrosion Resistant SteelsLCP73-2018/LADC-P-73-2018 HT 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215605AHEAT TREATMENTSSteelFPS-3014 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522Approved PCD W4.18.28 Rev. K10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
180002925CONTINENTAL HEAT TREATINGPQA215614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 10643 S. NORWALK BLVD.SANTA FE SPRINGSCA90670Ken NelsonQA Manager(562)944-8808
PMSPQA208COTEC CORPORATIONPQA208110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Titanium alloys only25, GONGDAN-5SACHEON, GYEONGSANGNAM10664-942J.H. Lee [+82]QA Manager(558)529-695
PMSPQA208COTEC CORPORATIONPQA208111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068CTS-WA-29-rev 16-Titanium alloys only25, GONGDAN-5SACHEON, GYEONGSANGNAM10664-942J.H. Lee [+82]QA Manager(558)529-695
PMSPQA208COTEC CORPORATIONPQA208615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD CTS-WA-35, Revision 09. TITANIUM ONLY.25, GONGDAN-5SACHEON, GYEONGSANGNAM10664-942J.H. Lee [+82]QA Manager(558)529-695
PMSPQA208COTEC CORPORATIONPQA208620PRE-PENETRANT ETCHTitanium Alloys-Alkaline/Acid Metal Remova MethodsSTP57-401Approved PCD CTS-WA-35, Revision 09.25, GONGDAN-5SACHEON, GYEONGSANGNAM10664-942J.H. Lee [+82]QA Manager(558)529-695
086090073CPPG INCPQA207614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 3905 E MIRALOMA AVEANAHEIMCA928066201Justino CantuQA Manager(714)572-3662
086090073CPPG INCPQA207232APLATINGChromeQQ-C-320 3905 E MIRALOMA AVEANAHEIMCA928066201Justino CantuQA Manager(714)572-3662
086090073CPPG INCPQA207232DPLATINGChromeProcess Spec C-0496 / 0496 3905 E MIRALOMA AVEANAHEIMCA928066201Justino CantuQA Manager(714)572-3662
947091666CRAFTECH METAL FORMING, INC.009923,10340160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD IM-3 Rev. AA.24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340600BHEAT TREATMENTSAluminumSTP 54-101 24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340600CHEAT TREATMENTSAluminumProcess Spec C-0521Approved PCD's IM-4 Rev. AA and IM-5 Rev. H.24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
947091666CRAFTECH METAL FORMING, INC.009923,10340401AWELDINGFusion WeldingSTP 55-104Approved only for GTAW, Class B, Manual Welding of Aluminum.24100 WATER AVE STE BPERRISCA925706738Uriel MandujanoQA Manager(951)940-6444
050793702CREATIVE PATHWAYS, INC.S01727,SSA029401WELDINGFusion WeldingMIL-STD-2219 3121 FUJITA STREETTORRANCECA90505Patti RohrbergOther Contact(310)530-1965
050793702CREATIVE PATHWAYS, INC.S01727,SSA029406AWELDINGFusionFPS-1095, Steel 3121 FUJITA STREETTORRANCECA90505Patti RohrbergOther Contact(310)530-1965
050793702CREATIVE PATHWAYS, INC.S01727,SSA029406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 3121 FUJITA STREETTORRANCECA90505Patti RohrbergOther Contact(310)530-1965
050793702CREATIVE PATHWAYS, INC.S01727,SSA029408AWELDINGFUSION WELDING - F-352ZZP00013Approved cleaning procedure CPI-EPS-100 Rev. F3121 FUJITA STREETTORRANCECA90505Patti RohrbergOther Contact(310)530-1965
079570351CROW PRECISION COMPONENTS, LLC942584510BFORGINGSSteel ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584325FORMINGFormingSTP51-302 Hot forming methods listed in Appendix A Section 1.3 onlyApproved PCD: Lockheed Forming and Fabrication per STP 51-302 Rev. 1200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
079570351CROW PRECISION COMPONENTS, LLC942584111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 supplier for pre-penetrant etch.200 LUXTON STFORT WORTHTX761041719Ben EubanksQA Manager(817)536-2861
187336503CUMING MICROWAVE CORPORATION240805,02382240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 264 BODWELL STAVONMA023221119Brian DunneQA Manager(508)521-6706
PMSPQA257CYCLONEPQA257200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BHot water seal not allowed for processing F-35 parts6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257200HANODIZEChromic Acid AnodizeSTP 58-209 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Conventional Only SOP 6 Rev D6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Tech Sheet IFT001 Rev B6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567SOP NDT 1 Rev G6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201SOP 35 Rev B Not approved for Fracture Critical Hardware6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257240APAINT and PRIMEPrime and PaintMIL-F-18264 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)SOP number P2 Rev D,SOP number P3 Rev D, TC0007 Rev D6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001SOP number F35 Rev NC6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Aluminum Only / SOP C3 Rev F6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257310SHOT PEENINGShot PeeningAMS 2430 6811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA257CYCLONEPQA257314SHOT PEENINGShot PeeningPS C-1476SH-P 1 Rev 3, Technique Sheet TS0363 Rev 0; TS0376; Rev. 0; TS0375; Rev. 1; TS0378; Rev. 16811 CENTURY DRIVEMISSISSAUGA ONTARIO10L5NAnkur SinghQA Manager(905)816-0056
PMSPQA256CYCLONE MANUFACTURINGPQA256167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 8001 PARKHILL DRIVEMILTON ONTARIO60L9TGlenn ZornQA Manager(905)567-5601
PMSPQA256CYCLONE MANUFACTURINGPQA256168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 8001 PARKHILL DRIVEMILTON ONTARIO60L9TGlenn ZornQA Manager(905)567-5601
PMSPQA256CYCLONE MANUFACTURINGPQA256170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)WI 11-11 rev 118001 PARKHILL DRIVEMILTON ONTARIO60L9TGlenn ZornQA Manager(905)567-5601
PMSPQA256CYCLONE MANUFACTURINGPQA256600CHEAT TREATMENTSAluminumProcess Spec C-0521WT HT-01-GEN Rev 20 /WF ID 438723098001 PARKHILL DRIVEMILTON ONTARIO60L9TGlenn ZornQA Manager(905)567-5601
PMSPQA256CYCLONE MANUFACTURINGPQA256606HEAT TREATMENTSAluminumAMS-2770 8001 PARKHILL DRIVEMILTON ONTARIO60L9TGlenn ZornQA Manager(905)567-5601
PMSPQA256CYCLONE MANUFACTURINGPQA256401AWELDINGFusion WeldingSTP 55-104 8001 PARKHILL DRIVEMILTON ONTARIO60L9TGlenn ZornQA Manager(905)567-5601
196474951CYGNUS, INC.009845,03164200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164200B1ANODIZESulfuric Acid Anodize Alternative for Type I/IBMIL-A-8625 Type IIBIn support of LMA PH090122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164200SANODIZEChromic Acid Anodize2ZZP00001 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164200VANODIZEThin Film Sulfuric AnodizeLMA-PH090 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=16897078%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D15155958%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Approved procedure PP0611 Rev B.122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164606HEAT TREATMENTSAluminumAMS-2770 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B and 1C.122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved procedure QA 1910, revision F. Not approved for Fracture Critical Hardware.122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164240APAINT and PRIMEPrime and PaintMIL-F-18264 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved procedure PP 0613, revision B.122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
196474951CYGNUS, INC.009845,03164148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved procedure PP 0613, revision B.122 EMERALD INDUS PK RDPONDERAYID83852Karen Thompson- QA Mgr of Integrated SysQA Manager(208)263-4761
SAPPQA899DAEHWA AEROSPACE INDUSTRIESPQA899169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) SOUTH KOREA KYUNG NAMGOSEONG 111111Lee In-Jong (I.J. Lee) [+82]QA Manager(556)738-5667
SAPPQA899DAEHWA AEROSPACE INDUSTRIESPQA899600BHEAT TREATMENTSAluminumSTP 54-101 SOUTH KOREA KYUNG NAMGOSEONG 111111Lee In-Jong (I.J. Lee) [+82]QA Manager(556)738-5667
SAPPQA899DAEHWA AEROSPACE INDUSTRIESPQA899606HEAT TREATMENTSAluminumAMS-2770 SOUTH KOREA KYUNG NAMGOSEONG 111111Lee In-Jong (I.J. Lee) [+82]QA Manager(556)738-5667
688179878DAESHIN AEROSPACE INDUSTRIESPQA262404CWELDINGResistance WeldingSTP 55-005Excludes Group A materials. Excludes Class A.667-1, BANGJI-RI, SANAM-MYUNSACHEON-CITY, KYUNGNAM  DW Jo (Daeshin Qual Mgr) [+82]QA Manager(558)542-877
056586019DECCO CASTINGS, INC.009541500ACASTINGSAluminum CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541512BCASTINGSNon-ferrous CastingsSTP53-400Approved PCD DCP-802.1-LM Rev. N/C IAW STP53-400AV01.1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Must use QCS-001 approved source for pre-penetrant etching.1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 approved source for pre-penetrant etching. Excludes LCP72-1068.1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Must use QCS-001 approved source for pre-penetrant etching. Approved PCD DCP-802.9-LM Rev. R-1.1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved Procedure DCP-802.8-LM Rev. R-1.1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
056586019DECCO CASTINGS, INC.009541406GWELDINGWeld Repair of CastingsSTP-55-801Certified Welder S. Dearinger.1596 PIONEER WAYEL CAJONCA920201673Kit KesingerQA Manager(619)444-9437
SAPPQA926DHAPPQA926110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 UNIT 1B LONG CLOSESALISBURY SP5 3HG GB  Tim ScuttQA Manager(078)904-3648
SAPPQA926DHAPPQA926111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 UNIT 1B LONG CLOSESALISBURY SP5 3HG GB  Tim ScuttQA Manager(078)904-3648
SAPPQA926DHAPPQA926615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)FC-WI:10-SOL-A4 Issue 1UNIT 1B LONG CLOSESALISBURY SP5 3HG GB  Tim ScuttQA Manager(078)904-3648
SAPPQA926DHAPPQA926401AWELDINGFusion WeldingSTP 55-104 UNIT 1B LONG CLOSESALISBURY SP5 3HG GB  Tim ScuttQA Manager(078)904-3648
078805421DICKSON TESTING CO., INC.PQA272162FRACTURE TOUGHNESS TESTINGFracture Toughness TestingASTM-E-399 11126 PALMER AVE.SOUTH GATECA90280Imtiyaz AhmedQA Manager(562)862-8378
078805421DICKSON TESTING CO., INC.PQA272169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Not approved for Webster, Barcol and Newage methods.11126 PALMER AVE.SOUTH GATECA90280Imtiyaz AhmedQA Manager(562)862-8378
008489056DIP BRAZE, INC.PQA273,05202425EBRAZINGDip BrazingMIL-B-7883 TYPE VApproved for 6xxx Series Aluminum Only.9131 DE GARMOSUN VALLEYCA913522608Mr. Robert ConnerQA Manager(818)768-1013
008489056DIP BRAZE, INC.PQA273,05202428BBRAZINGBrazing of AluminumLAC-1423 9131 DE GARMOSUN VALLEYCA913522608Mr. Robert ConnerQA Manager(818)768-1013
008489056DIP BRAZE, INC.PQA273,05202428CBRAZINGBrazing of AluminumPS C-1423 9131 DE GARMOSUN VALLEYCA913522608Mr. Robert ConnerQA Manager(818)768-1013
946076700DIVERSIFIED SERVICES, INC.PQA260110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 27 CLARK AVENUEWELLINGTONKS67152Jeremie GertenQuality Engineer(620)326-7655
946076700DIVERSIFIED SERVICES, INC.PQA260111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 27 CLARK AVENUEWELLINGTONKS67152Jeremie GertenQuality Engineer(620)326-7655
946076700DIVERSIFIED SERVICES, INC.PQA260111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567WI-750-01-008 rev B27 CLARK AVENUEWELLINGTONKS67152Jeremie GertenQuality Engineer(620)326-7655
946076700DIVERSIFIED SERVICES, INC.PQA260616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170WI-750-01-007, Rev D27 CLARK AVENUEWELLINGTONKS67152Jeremie GertenQuality Engineer(620)326-7655
946076700DIVERSIFIED SERVICES, INC.PQA260619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301WI-750-01-007, Rev D27 CLARK AVENUEWELLINGTONKS67152Jeremie GertenQuality Engineer(620)326-7655
960079531DIXON HARD CHROMEPQA271,05226601MHEAT TREATMENTSBaking of 600 Series Steel PartsLCP73-1008/P52002 11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008Limited to Stress Relief and Baking only.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved Procedure DHC XI Rev. C.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226115NON-DESTRUCTIVE TESTINGAcid Etch InspectionLADC-P-72-2016 11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226230APLATINGCadmiumQQ-P-416 Type I 11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226230BPLATINGCadmiumQQ-P-416 Type II 11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226230HPLATINGCadmiumSTP 58-001Not Approved for Aluminum. Niot approved for Corrosion and Heat Resistance Steels.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226230IPLATINGCadmiumLCP77-1061/LADC-P-77-1061Not Approved for Aluminum. Limited to under 180 ksi.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226230JPLATINGCadmium (P3 ONLY)C-0491Approved PCD DHC VIII-I Rev. N/C. Limited to Type I and II. Not approved for stainless steel or aluminum.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226230MPLATINGCadmium (C-130 ONLY)Process Spec 0491Not Approved for Aluminum.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226232APLATINGChromeQQ-C-320 11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226232CPLATINGChromeSTP 58-014Embrittlement Relief test results expire 05/31/2017.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226232DPLATINGChromeProcess Spec C-0496 / 0496INCLUDES STEEL OVER 220 KSI. Limited to Class II. Approved cleaning PCD DHC XXII, 02/17/2010.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226232FPLATINGChromeLCP77-2035/LADC-P-77-2035INCLUDES STEEL OVER 220 KSI11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226232GPLATINGChrome Plate GT220 KSIMIL-STD-1501 11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226233APLATINGCopperSTP 58-010Limited to Under 220 ksi.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234APLATINGElectroless NickelMIL-C-26074, Class 1 / (AMS 2404 Class 1 effective 01-01-2014)Limited to Under 220 ksi. Low phosphoruous only per AMS 2404.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234BPLATINGElectroless NickelMIL-C-26074, Class 2 (AMS 2404 Class 2 effective 01-01-2014)Limited to Under 220 ksi. Low phosphoruous only per AMS 2404.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234CPLATINGElectroless NickelMIL-C-26074, Class 3 (AMS 2404 Class 3 effective 01-01-201Limited to Under 220 ksi. Low phosphoruous only per AMS 2404.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234DPLATINGElectroless NickelMIL-C-26074, Class 4 (AMS 2404 Class 4 effective 01-01-2014Limited to Under 220 ksi. Low phosphoruous only per AMS 2404.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234FPLATINGElectroless NickelSTP 58-102INCLUDES STEEL OVER 220 KSI. Embrittlement Relief test results expire 05/16/2017.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234GPLATINGElectroless NickelProcess Spec C-0499 / 0499INCLUDES STEEL OVER 220 KSI. Approval Limited to Class IV and V. Approved PCD DHC XV-I EN Rev. N/C.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226234HPLATINGElectroless NickelLCP77-1055/LADC-P-77-1055INCLUDES STEEL OVER 220 KSI11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226237APLATINGTitanium-CadmiumSTP 58-005Embrittlement Relief test results expire 05/16/2017. Approval EXCLUDES C-5 Wing Modification.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
960079531DIXON HARD CHROMEPQA271,05226237CPLATINGTitanium-CadmiumLCP77-2033/LADC-P-77-2033Not approved for Corrosion Resistant and Heat Resistant Steel Parts. Type II approval only.11645 PENDLETON ST.SUN VALLEYCA91352Steve ArringtonQA Manager(818)767-9650
519842343DONCASTERSPQA499169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011) DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499401AWELDINGFusion WeldingSTP 55-104 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499401AWELDINGFusion WeldingSTP 55-104 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499404CWELDINGResistance WeldingSTP 55-005 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
519842343DONCASTERSPQA499404CWELDINGResistance WeldingSTP 55-005 DONCASTER PLC HOLBROOK WORKS HALFWAYSHEFFIELD, S20 3GB UK  Jim McCurrachQA Manager(114)251-2018
008484263DOWELL ALUMINUM FOUNDRY INC.009410,101380,05381512BCASTINGSNon-ferrous CastingsSTP53-400ALUMNINUM ONLY.11342 HARTLAND STNORTH HOLLYWOODCA916056387DeAnna McCartyQA Manager(323)877-9645
093245645DUCOMMUN AEROSTRUCTURES EL MIRAGEPQA091300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051Approved Procedure 1100-16 Rev. B.4001 EL MIRAGE ROADADELANTOCA923010040Kevin LanFrancoQA Manager(760)246-4191
093245645DUCOMMUN AEROSTRUCTURES EL MIRAGEPQA091300DCHEM MILLING / DESCALINGTitanium Chem MillingFPS-1051Approved Procedure SOP EM-002 Rev. A.4001 EL MIRAGE ROADADELANTOCA923010040Kevin LanFrancoQA Manager(760)246-4191
093245645DUCOMMUN AEROSTRUCTURES EL MIRAGEPQA091304CHEM MILLING / DESCALINGChemical Milling of MetalsLMA-PA051 4001 EL MIRAGE ROADADELANTOCA923010040Kevin LanFrancoQA Manager(760)246-4191
041326216DUCOMMUN AEROSTRUCTURES, INC005439,00430300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051Approved Procedure APS 1100-16 Rev. B1885 N Batavia StOrangeCA928654105Paul WrightQA Manager(310)380-5565
041326216DUCOMMUN AEROSTRUCTURES, INC005439,00430302CHEM MILLING / DESCALINGChem MillingMIL-C-81769 1885 N Batavia StOrangeCA928654105Paul WrightQA Manager(310)380-5565
041326216DUCOMMUN AEROSTRUCTURES, INC005439,00430305CHEM MILLING / DESCALINGChemical MillingPS 0450 1885 N Batavia StOrangeCA928654105Paul WrightQA Manager(310)380-5565
041326216DUCOMMUN AEROSTRUCTURES, INC005439,00430161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1885 N Batavia StOrangeCA928654105Paul WrightQA Manager(310)380-5565
621598671DYNAMIC FABRICATION INCPQA275401WELDINGFusion WeldingMIL-STD-2219 2615 HICKORY STREETSANTA ANACA92701Mike KartsonisQA Manager(714)662-2440
621598671DYNAMIC FABRICATION INCPQA275401AWELDINGFusion WeldingSTP 55-104 2615 HICKORY STREETSANTA ANACA92701Mike KartsonisQA Manager(714)662-2440
621598671DYNAMIC FABRICATION INCPQA275406AWELDINGFusionFPS-1095, Steel 2615 HICKORY STREETSANTA ANACA92701Mike KartsonisQA Manager(714)662-2440
621598671DYNAMIC FABRICATION INCPQA275406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 2615 HICKORY STREETSANTA ANACA92701Mike KartsonisQA Manager(714)662-2440
621598671DYNAMIC FABRICATION INCPQA275406DWELDINGFusionFPS-1095, Aluminum 2615 HICKORY STREETSANTA ANACA92701Mike KartsonisQA Manager(714)662-2440
621598671DYNAMIC FABRICATION INCPQA275408AWELDINGFUSION WELDING - F-352ZZP00013Approved Cleaning PCD DFI-101-230 Rev. B.2615 HICKORY STREETSANTA ANACA92701Mike KartsonisQA Manager(714)662-2440
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009Approved for Webster Hardness Gage only.AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318606HEAT TREATMENTSAluminumAMS-2770 AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Level 3 Steve Garner.AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved Procedure ENG-00027 Rev. L.AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742Level 3 Steve Garner.AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Approved Procedure ENG-00032 Rev. H.AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318240APAINT and PRIMEPrime and PaintMIL-F-18264Limited to 2ZZP00001 specification.AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
PMSPQA318EATON INDUSTRIES MFG GMBHPQA318408AWELDINGFUSION WELDING - F-352ZZP00013 AV. SANTA ROSALIA 9707TIJUANA, BAJA CALIFORNIA 67Fernando GuillenQA Manager(664)978-1689
016377926EATON-AEROQUIP LLC.026442,00480,00737206CHEMICAL CONVERSION COATINGTitanium Conversion CoatingAMS-2486 300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved Non-Critical Parts and Critical Parts, not F/ACESC Parts. ACES No. 2600 Rev. BT WF ID 55300712300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737123NON-DESTRUCTIVE TESTINGX-RayLMA-PC3012602 Rev. AH approved WF ID -55307393300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737401DWELDINGFusion WeldingAWS D17.1 300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
016377926EATON-AEROQUIP LLC.026442,00480,00737408AWELDINGFUSION WELDING - F-352ZZP00013Titanium cleaning procedure AP1178, revision AP, pending approval300 S EAST AVEJACKSONMI492031973David StatenQA Manager(517)789-2790
600006480ELBIT SYSTEMS - CYCLONE LTD.244862200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: TY IB only. Not Approved for F-35BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862910BONDING AND COMPOSITESAdhesive Bonded AssembliesFPS-3016 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613934%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Supplier is restricted to those parts listed in the FQPLBAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862913BONDING AND COMPOSITESPlasticsFPS-3026 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613843%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Supplier is restricted to those parts listed in the FQPLBAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862930BONDING AND COMPOSITESHorizontal SkinFPS-3560 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614050%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Supplier is restricted to those parts listed in the FQPL.BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051PCD: CPS03_34_04 rev E / WF ID 42757956BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862606HEAT TREATMENTSAluminumAMS-2770 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCEPT ZONE 1A,1B,1CBAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862163NON-DESTRUCTIVE TESTINGEddy CurrentNDTS-1601Only Inspector Is Dr. Josef Pessach of Morex 71 LTDBAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862919NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonding and CompositesNDTS-5103 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862240APAINT and PRIMEPrime and PaintMIL-F-18264 BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
600006480ELBIT SYSTEMS - CYCLONE LTD.244862110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PCD: CPS03_34_08 rev C / WF ID 42763128BAR LEV INDUSTRIAL PARKKARMIEL552161002Avi SchweitzerQA Manager(499)607-50
755372195ELECTROMOLD AUSTRALIAPQA300200SANODIZEChromic Acid Anodize2ZZP00001 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300200VANODIZEThin Film Sulfuric AnodizeLMA-PH090 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=16897078%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D15155958%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.WP-058 Rev 9202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016WP-091 Rev 6202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444WP 062 Rev 09202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007WP 062 Rev 09202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417WP-068 Rev 13202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201WP-068 Rev 13202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 11-30-2019202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300240APAINT and PRIMEPrime and PaintMIL-F-18264 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Aluminum WP-059 Rev 8 ST-021 Rev 23202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001WP-085 Rev 7202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001WP-084 Rev 3 ST-021 Rev 23202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
755372195ELECTROMOLD AUSTRALIAPQA300251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 202 HOLT PARADETHOMASTOWN, VICTORIA723074Michael SalisburyQA Manager 
001792352ELEMENT101347,PQA777100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, 1C. Excludes Titanium.18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Limited to STP53-201 only. Approved for Aluminum only.18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777111BNON-DESTRUCTIVE TESTINGPenetrant InspectionP54003 18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved PCD RT-002H Addm 20A.18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved Procedure EP-002 Rev. i and EP-002i Addm. 4 Rev. C.18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
001792352ELEMENT101347,PQA777619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD EP-002 Rev. i and EP-002i Addm. 10 Rev. E.18100 S. WILMINGTON AVE SUITE 200RANCHO DOMINGUEZCA90220Julie NguyenQA Manager(310)632-8500
PMSPQA624ELEMENT MATERIALS TECHNOLOGYPQA624162FRACTURE TOUGHNESS TESTINGFracture Toughness TestingASTM-E-399 15062 BOLSA CHICA ST.HUNTINGTON BEACHCA92649Stephanie SalasQA Manager(714)892-1961
045521184EME, INC.S02349,PQA315200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD SMPP number 6S-58-208 Rev. A (WF ID -47479038)431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315200SANODIZEChromic Acid Anodize2ZZP00001 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315202ANODIZETitanium AnodizeAMS-2488 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approval Class 1 and 2 and Types I and II. Approved PCD SMPP 11 STP58-405 Revision A.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016Approved Procedure SMPP 45-T-LMA Rev. New.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD SMPP number 16B-G639, Revision B, approved on WF ID -48748664 on 02/25/2015431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Limited to aluminum material testing only.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Limited to aluminum material testing only.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C. Excludes steel431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 approved source for pre-penetrant etching of titanium.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315111BNON-DESTRUCTIVE TESTINGPenetrant InspectionP54003 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD SMPP Number 73-C-0567F, Revision A, approved on Work Flow ID number 48336034 on 12/10/2014431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved PCD SMPP 74-LMA-PC201 Rev. B.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201EMEs approval for LMA-PC201 Fracture Critical Penetrant limited to inspectors Joe Lipsey and Desmond Handley (Expires 06/2017)431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315240APAINT and PRIMEPrime and PaintMIL-F-18264 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.SMPP number 210-1-1101, Rev. B, dated 6/3/05431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001SMPP 03-LMA1-AL 08/13/10431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001Approved Procedure SMPP 03-LMA1-T1 Rev. New.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301SMPP 03 LMA1 57-301 Rev. A431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
045521184EME, INC.S02349,PQA315251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010Excludes Copper, Magnesium and Steel alloys.431 E. OAKS PO BOX 4998COMPTONCA90222John Lopez Jr.QA Manager(310)639-1621
008033169ESSNER MANUFACTURING, L.P.004460,18656210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Type 1 and 3.6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness and conductivity only- no tensile capability.6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656600BHEAT TREATMENTSAluminumSTP 54-101Aluminum wrought products6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656606HEAT TREATMENTSAluminumAMS-2770Aluminum wrought product and parts only, no forgings or castings6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656240APAINT and PRIMEPrime and PaintMIL-F-18264 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
008033169ESSNER MANUFACTURING, L.P.004460,18656404BWELDINGResistance WeldingMIL-W-6858Class C only6651 WILL ROGERS BLVD BFORT WORTHTX761406055Edgar LunaQA Manager(817)551-5511
400414017EURO COMPOSITES SA013048,24862120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742Composites Only Real Time X-RayZONE INDUSTRIELLEECHTERNACH896468Mr. Arno Tolkes (+352)QA Manager(729)463-296
400414017EURO COMPOSITES SA013048,24862123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Composites Only Real Time X-RayZONE INDUSTRIELLEECHTERNACH896468Mr. Arno Tolkes (+352)QA Manager(729)463-296
799960547EXOVA INCSSA018162FRACTURE TOUGHNESS TESTINGFracture Toughness TestingASTM-E-399 10005 FREEMAN AVE.SANTA FE SPRINGSCA90670David TalliniQA Manager(562)946-1721
SAPPQA358FERRA AEROSPACE, INC.PQA358240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 336 INDUSTRIAL RD. AGROVEOK74344Jeff TillerQA Manager(918)787-2220
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200HANODIZEChromic Acid AnodizeSTP 58-209 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200IANODIZEChromic Acid AnodizeProcess Spec C-0494 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200JANODIZEChromic Acid AnodizeLCP77-2038/LADC-P-77-2038 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD: FQMF-002 Sup. 1 Rev. A1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253200SANODIZEChromic Acid Anodize2ZZP00001 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD FQMF-003 Supplement 1 Rev. ORG1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD FQMF-003 Supplement 1 Rev. ORG1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253210CCHEMICAL CONVERSION COATINGChem FilmP56011 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639FQMF 750 Appendix A1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253622HEAT TREATMENTSStress Relieving and BakingC-0531 (Effective 01-01-2014)Approved PCD: FQMF 725 Rev A (WF ID -47065270)1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD: FQMF-740 Rev. A Sup. 11640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253240APAINT and PRIMEPrime and PaintMIL-F-18264 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)Approved PCD: FQMF 736 Rev A (WF ID -46517330)1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253239CPHOSPHATEPhospateSTP 58-302 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253239DPHOSPHATEPhosphateMIL-DTL-16232, Type Z or M, Class 1,3 (Class 2 effective 01-01-2014) 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253230APLATINGCadmiumQQ-P-416 Type I 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253230BPLATINGCadmiumQQ-P-416 Type II 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253230CPLATINGCadmiumQQ-P-416 Type III 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253230HPLATINGCadmiumSTP 58-001 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253230JPLATINGCadmium (P3 ONLY)C-0491Approved (WF ID44862872) PCD: FQMF 728 Rev. C1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources. 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Approved PCD FQMF-730 Rev. ORG1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Approved PCD FQMF-730 Rev. ORG1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101Approved PCD FQMF-732 Rev. ORG1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD FQMF-734 Rev. A1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253621PRE-PENETRANT ETCHCopper Alloys (Alkaline/Acid Methods Only)STP57-701Approved PCD FQMF-731 Rev. ORG1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010Excludes Copper/Copper Alloys, Magnesium/Magnesium Alloys, and Titanium/Titanium Alloys1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
008263733FINE QUALITY METAL FINISHING INC.PQA931,24253252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005 1640 DAISY AVENUELONG BEACHCA90813Raymond Charles EsfandiQA Manager(562)432-2248
009653494FLYTE-WELD, INC.PQA342401AWELDINGFusion WeldingSTP 55-104 6833 TUJUNGA AVE.N. HOLLYWOODCA91605Chris MogensenQA Manager(818)769-6629
009653494FLYTE-WELD, INC.PQA342401B1WELDINGFusion WeldingLADC-P-74-2022 6833 TUJUNGA AVE.N. HOLLYWOODCA91605Chris MogensenQA Manager(818)769-6629
009653494FLYTE-WELD, INC.PQA342401DWELDINGFusion WeldingAWS D17.1 6833 TUJUNGA AVE.N. HOLLYWOODCA91605Chris MogensenQA Manager(818)769-6629
009653494FLYTE-WELD, INC.PQA342406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 6833 TUJUNGA AVE.N. HOLLYWOODCA91605Chris MogensenQA Manager(818)769-6629
782160758FMH AEROSPACE CORP.006563,06707110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDES ZONE 1A, 1B, and 1C. QCS-001 source must be used for pre-penetrant etching.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068QCS-001 SOURCE MUST BE UTILIZED FOR PRE-PENETRANT ETCHING. Excludes LCP72-1068.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved for Non-Critical Parts and Critical Parts. Not Approved For Fracture Critical Parts.Approved procedure FPS-100-1, revision Z. QCS-001 SOURCE MUST BE UTILEZED FOR PRE-PENETRANT ETCHING.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301APPROVED PROCEDURE FPS 315, Revision W.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707145NON-DESTRUCTIVE TESTINGX-Ray5PTPCG05APPROVED PROCEDURE FPS 315, Revision W.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Approved for Non-Critical Parts and Critical Parts. Not Approved For Fracture Critical Parts. Approved Procedure FPS-100-1, Revision Z. ETCH MUST BE DONE BY QCS-001 SOURCE.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707401WELDINGFusion WeldingMIL-STD-2219 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707401AWELDINGFusion WeldingSTP 55-104Approved PCD FPS 17013-701, revision I, dated 10/17/201117072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707404CWELDINGResistance WeldingSTP 55-005Group b materials only. Approved cleaning PCD FPS 17013-701, revision I, dated 10/17/201117072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707406AWELDINGFusionFPS-1095, Steel 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707406CWELDINGFusionFPS-1095, Copper Nickel Alloys 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707406DWELDINGFusionFPS-1095, Aluminum 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707406EWELDINGFusionFPS-1095, Titanium 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707408WELDINGFusion5PTPET01 17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
782160758FMH AEROSPACE CORP.006563,06707408AWELDINGFUSION WELDING - F-352ZZP00013Approved Titanium cleaning procedure MP-203-4, revision F.17072 DAIMLER STIRVINECA926145548Howard HulinQA Manager(714)751-1000
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: Not Approved for F-35INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: TY 1B7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Hand Lay Tape or Fabric, Non-Critical and Critical Parts (Qual. Report No. 2ZZA00544)7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005832ABONDING AND COMPOSITESJSF Epoxy Fabrication2ZZP00004 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396622%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Hand Lay Tape or Fabric7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005840BONDING AND COMPOSITESJSF BONDING and COBONDING PARTS WITH EPOXY MATLS2ZZP00039 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18397315%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Tape or Fabric Bonded Parts, Non-critical, Not Approved for Metallic Surface Preparation7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005841BONDING AND COMPOSITESJSF BONDING and COBONDING PARTS WITH BMI MATERIALS2ZZP00042 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396679%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Tape or Fabric Bonded Parts Non-critical7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710910BONDING AND COMPOSITESAdhesive Bonded AssembliesFPS-3016 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613934%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051PCD: FP-1080 issue 017 Lockheed / WF 48026427INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3PCD: FP-1095E issue 019 (F-16) / WF 48243956INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710606HEAT TREATMENTSAluminumAMS-2770 INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417PCD TH 14.5350 is 24 / WF 509465677900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417PCD: FP-1040E is 001 / WF ID 46830835INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.PCD: FP-1040E is 001 / WF ID 46830835INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD TH 14.5350 is 24 / WF 50946567, INBL P043 is H, P048 is I, P051 is 37900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301PCD TH 14.5320 issue 13 / WF ID 42210142INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001PCD: INBL F35-2VSH56231-UT is2 / 2VSH42130-UT is3 / PN Specific - LM L3 Vanproyen, Dave7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710919NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonding and CompositesNDTS-5103 INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
402078096FOKKER AEROSTRUCTURES B.V.356890,356891,02710240APAINT and PRIMEPrime and PaintMIL-F-18264FOKKER SPEC. TH7429INDUSTRIEWEG 4PAPENDRECHT703351 LBMr. Christoffel Grootaarts (+31)QA Manager(630)721-361
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005240APAINT and PRIMEPrime and PaintMIL-F-18264 7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Grandfathered / MIL-F-182647900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD FP-1092E is 13 / WF 49898871, Not approved for localized etching7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
408331507FOKKER AEROSTRUCTURES B.V.013320,JS9002,IQA005148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001PCD: FP-1090 rev 12 - WF 52156010 / Limitation: 13-8 MO only7900 AB HOOGEVEEN EDISONSTRAAT 1 PO BOX 59EDISONSTRAAT 00000Hans StrikkersQA Manager 
157574492FORT WALTON MACHINING, INC.013283200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283200CANODIZEHard AnodizeMIL-A-8625, Type III 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283200LANODIZESulfuric Acid AnodizeSTP 58-208SPS 7.0.072 Rev C43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405SPS 7.0.073 Rev A43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498SPS 7.0.073 Rev A43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639SPS SPS 7.0.044 Rev H43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.SPS 7.0.034 Rev F43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567SPS 7.0.034 Rev F43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201SPS 7.0.034 Rev F Not approved for Fracture Critical Hardware inch43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283240APAINT and PRIMEPrime and PaintMIL-F-18264 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)SPS SPS 7.0.044 Rev H43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.SPS 7.0.074 Rev IR43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001SPS 7.0.057 Rev C43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)SPS 7.0.074 Rev IR43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170SPS 7.0.074 Rev IR43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
157574492FORT WALTON MACHINING, INC.013283619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301SPS 7.0.074 Rev IR43 JET DR NWFORT WALTON BEACHFL325484807Dan GustafsonQA Manager(850)244-9095
004091401FREEDOM METAL FINISHING, INC010149,PQA270200HANODIZEChromic Acid AnodizeSTP 58-209 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270200LANODIZESulfuric Acid AnodizeSTP 58-208MPS-039 Rev 3 approved 6/23/135095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approval limited to Class 1, conventional, special etch. MPS-033-022 Rev 3 dated 12/21/11.5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639G639-0001-ND Rev 4 and G639-0001/-0002 WD and ND Rev NC - WF ID -40186379 approved 1/23/12.5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270240APAINT and PRIMEPrime and PaintMIL-F-18264 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270230APLATINGCadmiumQQ-P-416 Type I 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
004091401FREEDOM METAL FINISHING, INC010149,PQA270342APLATINGSilver Electro-DepositedProcess Spec 0501 5095 113TH AVENUE NORTHCLEARWATERFL33760John MeyersQA Manager(727)573-2464
003557969G K N AEROSPACE NORTH AMERICA009515,02118802ABONDING AND COMPOSITESBMI Fabrication5PTPLL11 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14822357%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440034%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 142 JS MCDONNELL BLVDSAINT LOUISMO63135Jeff DillingerQuality Engineer(314)264-4893
003557969G K N AEROSPACE NORTH AMERICA009515,02118843BONDING AND COMPOSITESCOMPOSITE FABRICATION FACILITY5PTPPL01 142 JS MCDONNELL BLVDSAINT LOUISMO63135Jeff DillingerQuality Engineer(314)264-4893
003557969G K N AEROSPACE NORTH AMERICA009515,02118120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742Composite detail and assemblies only142 JS MCDONNELL BLVDSAINT LOUISMO63135Jeff DillingerQuality Engineer(314)264-4893
003557969G K N AEROSPACE NORTH AMERICA009515,02118122BNON-DESTRUCTIVE TESTINGX-Ray5PTPCT04Composite detail and assemblies only142 JS MCDONNELL BLVDSAINT LOUISMO63135Jeff DillingerQuality Engineer(314)264-4893
003557969G K N AEROSPACE NORTH AMERICA009515,02118132BNON-DESTRUCTIVE TESTINGUltrasonic Inspection5PTPCT01Composite detail and assemblies only142 JS MCDONNELL BLVDSAINT LOUISMO63135Jeff DillingerQuality Engineer(314)264-4893
058671504GAMMA ENGINEERING, INC.005776,24441242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441600BHEAT TREATMENTSAluminumSTP 54-101 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441602EHEAT TREATMENTSTitaniumAMS-2801 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441605AHEAT TREATMENTSSteelFPS-3014Limited to stress relieving and aging of Class D (PH steel) only.601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441606HEAT TREATMENTSAluminumAMS-2770 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441240APAINT and PRIMEPrime and PaintMIL-F-18264 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
058671504GAMMA ENGINEERING, INC.005776,24441240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 601 AIRPORT DRMANSFIELDTX760632718Dave WatkinsQA Manager(817)477-2193
172264611GEL INDUSTRIES, INC.010489,728533510AFORGINGSAluminum ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
172264611GEL INDUSTRIES, INC.010489,728533513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562ALUMINUM FORGINGS ONLY.810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
172264611GEL INDUSTRIES, INC.010489,728533160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
172264611GEL INDUSTRIES, INC.010489,728533161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
172264611GEL INDUSTRIES, INC.010489,728533600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) 810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
172264611GEL INDUSTRIES, INC.010489,728533110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
172264611GEL INDUSTRIES, INC.010489,728533110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C810 N LEMON STORANGECA928676616Bob StewartQA Manager(714)639-8191
099593592GENERAL DYNAMICS-OTS, INC.006965,154183,00905,03173819BONDING AND COMPOSITESFabrication of H/C Nonmetallic Faced SandwichSTP60-105 150 JOHNSTON RDMARIONVA243544324Pam BlevinsQA Manager(276)783-1337
099593592GENERAL DYNAMICS-OTS, INC.006965,154183,00905,03173833BONDING AND COMPOSITESComposite Parts Surveillance and QualificationLMA-D0010 150 JOHNSTON RDMARIONVA243544324Pam BlevinsQA Manager(276)783-1337
SAPPQA995GENERAL ENGINEERING LTDPQA995200LANODIZESulfuric Acid AnodizeSTP 58-208WI25A Rev 3 approved by Danals6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
SAPPQA995GENERAL ENGINEERING LTDPQA995110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
SAPPQA995GENERAL ENGINEERING LTDPQA995111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
SAPPQA995GENERAL ENGINEERING LTDPQA995150DNON-DESTRUCTIVE TESTINGEtch Inspection of High Strength Steel PartsSTP 53-701PCD: AEI 002 rev 2 / WF 54337226. Limitation: Material below 220 ksi6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
SAPPQA995GENERAL ENGINEERING LTDPQA995246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
SAPPQA995GENERAL ENGINEERING LTDPQA995247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
SAPPQA995GENERAL ENGINEERING LTDPQA995619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301WI 24 issue 6 approved by Danals6 VANGUARD WAYSHOEBURYNESS ESSEX ss39QYPhil Hearne 441702256011QA Manager 
556050334GIVON USA, INC.009335160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2300 MERRILL CREEK PKWY # 300EVERETTWA982035855Dave MullkoffQA Manager(425)355-3330
556050334GIVON USA, INC.009335161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2300 MERRILL CREEK PKWY # 300EVERETTWA982035855Dave MullkoffQA Manager(425)355-3330
556050334GIVON USA, INC.009335167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 2300 MERRILL CREEK PKWY # 300EVERETTWA982035855Dave MullkoffQA Manager(425)355-3330
556050334GIVON USA, INC.009335168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 2300 MERRILL CREEK PKWY # 300EVERETTWA982035855Dave MullkoffQA Manager(425)355-3330
556050334GIVON USA, INC.009335240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013Reviewed procedure WI 900, Revision B.2300 MERRILL CREEK PKWY # 300EVERETTWA982035855Dave MullkoffQA Manager(425)355-3330
002044162GKN AEROSPACE MONITOR, INC.624217240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013Titanium alloys only.1000 NEW HORIZONS BLVDAMITYVILLENY117011138Timothy MarxQA Manager(631)761-1336
788119142GKN AEROSPACE PRECISION MACHIN717475,24105240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013GOP 7-5-5 rev EINC.429 N WEST RDWELLINGTONKS671528047Gary Bickel (x193)QA Manager(620)326-5952
SAPPQA928GKN AS YEOVILPQA928210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Limited to Class 1 only. Excludes Class 2 and Class 1 special etch. Approved PCD SP-CP-ALC-01, Issue 9.BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928600BHEAT TREATMENTSAluminumSTP 54-101 BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928606HEAT TREATMENTSAluminumAMS-2770 BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014)Excludes MIL-PRF-83285 materials.BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCD: SP/NDT/PFD/003, Is 12 (immersion and swab etching) WF 49919908BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
SAPPQA928GKN AS YEOVILPQA928404CWELDINGResistance WeldingSTP 55-005Approvals limited to Class B for Groups A and B only.BOX 150 LYSANDER ROADYEOVIL BA202YB GB  Christopher WiscombeQA Manager 
609913538GKN WESTLAND AEROSPACE, INC.003873,009169,00597831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 3951 AL HIGHWAY 229 STALLASSEEAL360784733Jim HinzQuality Engineer(334)398-3069
609913538GKN WESTLAND AEROSPACE, INC.003873,009169,00597832ABONDING AND COMPOSITESJSF Epoxy Fabrication2ZZP00004 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396622%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 3951 AL HIGHWAY 229 STALLASSEEAL360784733Jim HinzQuality Engineer(334)398-3069
609913538GKN WESTLAND AEROSPACE, INC.003873,009169,00597240APAINT and PRIMEPrime and PaintMIL-F-18264 3951 AL HIGHWAY 229 STALLASSEEAL360784733Jim HinzQuality Engineer(334)398-3069
609913538GKN WESTLAND AEROSPACE, INC.003873,009169,00597240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 3951 AL HIGHWAY 229 STALLASSEEAL360784733Jim HinzQuality Engineer(334)398-3069
007235229GLOBE ENGINEERING CO., INC.400932160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)P1.9.030 rev P1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932600BHEAT TREATMENTSAluminumSTP 54-101Omission of the ammonium fluoborate requirements approved per Richard Weber.1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932600CHEAT TREATMENTSAluminumProcess Spec C-0521SMPP P1.9.110-01 Rev:N/C1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932602EHEAT TREATMENTSTitaniumAMS-2801Approval limited to annealing and stress relieve only1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932605AHEAT TREATMENTSSteelFPS-3014 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932606HEAT TREATMENTSAluminumAMS-2770 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932609HEAT TREATMENTSSteelAMS-2759 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068P1.9.1501539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved procedure 1-WI PI 9150-002 F-35. Not approved for Fracture Critical Hardware.1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001SMPP P.1.9006-02, 8-26-20131539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)SMPP P1.9.006-01 Rev. B. steel and aluminum only1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170SMPP P1.9.006-01 Rev. B. steel and aluminum only1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD 49035162,SMPP P1.9.015-01 Rev. A, 6-1-20151539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932401WELDINGFusion WeldingMIL-STD-2219 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932401AWELDINGFusion WeldingSTP 55-104 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932401DWELDINGFusion WeldingAWS D17.1 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932404BWELDINGResistance WeldingMIL-W-6858 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932404CWELDINGResistance WeldingSTP 55-005 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932404EWELDINGResistance WeldingC-1421SMPP.1.9.005.0011539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932406DWELDINGFusionFPS-1095, Aluminum 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932408AWELDINGFUSION WELDING - F-352ZZP00013SMPP P.1.9006-02, 8-26-20131539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
007235229GLOBE ENGINEERING CO., INC.400932413WELDINGResistance Welding for Aerospace ApplicationsAWS D17.2 (Approval required by 01-01-2014) 1539 S SAINT PAUL STWICHITAKS672131797Andrew ChambersQA Manager(316)943-1266
151326402GOLDEN STATE MAG. and PEN. LABPQA363100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363101BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionP54002 9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 source for pre-penetrant etching.9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363111BNON-DESTRUCTIVE TESTINGPenetrant InspectionP54003 9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363240APAINT and PRIMEPrime and PaintMIL-F-18264PROCESS BULLITEN 15. Approval includes MIL-DTL-18264E.9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
151326402GOLDEN STATE MAG. and PEN. LABPQA363246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 9301 LAUREL CANYONARLETACA913311968Thomas KristensenQA Manager(818)767-5767
PMSPQA921H and W GLOBAL INDUSTRIESPQA921200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921200LANODIZESulfuric Acid AnodizeSTP 58-208LM-PCD-003 Rev B dated 9/5/13.414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405LMA-PCD-002 Rev E -Conventional Only414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)LM-PCD-001 rev F flash clean only414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
PMSPQA921H and W GLOBAL INDUSTRIESPQA921619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301LM-PCD-001 rev F flash clean only414 INNOVATION DR.BLAIRSVILLEPA15717-8096Sandi HabetsQA Manager(724)459-5316
800341948H. M. DUNN COMPANY, INC.001583,18399240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013MS 73 03 REV. NEW1252 S VANDEVENTER AVESAINT LOUISMO631103808Brian MagacQA Manager(314)355-6684
096541669H. M. DUNN COMPANY, INC.008687,011038240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 4201 S 119TH ST WWICHITAKS672159100Cameron DriskillQA Manager(316)529-0421
064415730HAR-CONN AEROSPACE, INC.004786,PQA401200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401202ANODIZETitanium AnodizeAMS-2488TYPE 2 ONLY5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401240APAINT and PRIMEPrime and PaintMIL-F-18264 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
064415730HAR-CONN AEROSPACE, INC.004786,PQA401251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 5000 AUGUSTA DR.FT. WORTHTX76106Brian HoranQA Manager(817)538-0075
213969509HAUCK HEAT TREATMENT LTDPQA797601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI BLACKHOURSE ROAD, LETCHWORTH GARDEN CITYHERTFORD SG6 1HDAlex Goodman (+44)QA Manager(146)247-2100
213969509HAUCK HEAT TREATMENT LTDPQA797601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 BLACKHOURSE ROAD, LETCHWORTH GARDEN CITYHERTFORD SG6 1HDAlex Goodman (+44)QA Manager(146)247-2100
612427182Heart of Georgia Dynamics, Inc013365,PQA292200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292200HANODIZEChromic Acid AnodizeSTP 58-209 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292200LANODIZESulfuric Acid AnodizeSTP 58-208CF10.01 rev 1-29-2014415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405CL1 convent-special etch.CL2, CF-02 Rev 6, 12/10/2014415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Special and conventional etch PS C-0498 Rev E Type I and CF-02 Rev 6, 12/10/2014415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639PA05.01 Rev 001; 10-31-2011415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.NDT 01.05 Rev 00 Excludes Zones 1A, 1B, and 1C415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068NDT-01.01 Rev 01, 2/29/2009415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567NDT 01.01 Rev 01, 2/29/2009415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201NDT 01.04 Rev 02, 1/28/16415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification Approval Expires 08/31/2018415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292163NON-DESTRUCTIVE TESTINGEddy CurrentNDTS-1601Approval is limited to P/N 16W014-237/238 TDS DPS-ET-102 Dated Feb. 10, 2013415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292240APAINT and PRIMEPrime and PaintMIL-F-18264 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)OPP -A-12, 1-29-2014415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.CF08 -2 Rev 00, 1/25/2010415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001CF08.01-01 Rev 01,12/21/2009415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)CF08.01 Rev 01, 11/3/2011415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170CF08.01 Rev 01, 11/3/2011415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301CF08.01 Rev 01, 11/3/2011415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292311SHOT PEENINGShot PeeningSTP51-501 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292314SHOT PEENINGShot PeeningPS C-1476PS1476 has been superceded by STP51-501 (Process code 311)415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
612427182Heart of Georgia Dynamics, Inc013365,PQA292252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005 415 AIRPORT ROADEASTMANGA31023Craig SwindellQA Manager(478)374-5402
012556775HERCULES HEAT TREATING CORP.PQA388601BHEAT TREATMENTSSteelSTP 54-006, Above 220 KSI 101-113 CLASSON AVE.BROOKLYNNY11205Anthony RizzoQA Manager(718)625-1266
012556775HERCULES HEAT TREATING CORP.PQA388601EHEAT TREATMENTSSteel5PTPDL07, Above 220 KSI 101-113 CLASSON AVE.BROOKLYNNY11205Anthony RizzoQA Manager(718)625-1266
012556775HERCULES HEAT TREATING CORP.PQA388608HEAT TREATMENTSAermet 100 Steel5PTPDT01 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14620842%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440034%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 101-113 CLASSON AVE.BROOKLYNNY11205Anthony RizzoQA Manager(718)625-1266
001545123HI-TECH METALS, INC.010569200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569200HANODIZEChromic Acid AnodizeSTP 58-209PI-023, Rev C3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569200LANODIZESulfuric Acid AnodizeSTP 58-208PI-007 REVE3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3PI-006 Rev C3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approval limited to Class 1, and Type II (special etch) PI-006, Rev C3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PI7.5.1-14C3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016Procedure PI 7.5.1-14, Rev G3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501HITOP-009-08 REV F3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502HITOP-009-09, REV B3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008aproved 12/04/20103100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101Procedure HITOP-009-003 Rev N3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001Procedure HITOP-009-003 Rev N3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007WF ID -52156909 approved at rev X3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Procedure HITOP-009-04 Rev Z: Limited to Method A3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDES ZONES 1A, 1B AND 1C3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068HITOP-009-04,, REVZ3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567HITOP-009-04 REVZ3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201approved with the exceptionof fracture critical3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201PI 8.2.4-2 Rev AF - WF ID -51127584 Requal 11/30/2018 part size limit 8' x 3' x 4'3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Critical approved excluding fracture crit. Procedure HITOP-009-04 Rev U3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569240APAINT and PRIMEPrime and PaintMIL-F-18264 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014) 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569248PAINT and PRIMETouch-Up Requirements for Finishes On P-3C-395-M (Effective 01-01-2014) 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569230APLATINGCadmiumQQ-P-416 Type I 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569230BPLATINGCadmiumQQ-P-416 Type II 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569230HPLATINGCadmiumSTP 58-001 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569230JPLATINGCadmium (P3 ONLY)C-0491 3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569230MPLATINGCadmium (C-130 ONLY)Process Spec 0491PI 7.5.1-9G3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.ALUMINUM ONLY PER PI-004 approved by P. Ullman3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569146B1PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGG01Approved to PI-7-1-25 Rev C approved by J JohnsonnO USAGE IN THE LAST 4 REPORTING PERIODSD3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569146B2PRE-PENETRANT ETCHPre-Penetrant Etch - Titanium5PTPGG01Approved by J. Johnson M and P F-22 Approved to PI-004 n/c dated 7/23/04 nO USAGE IN THE LAST 4 REPORTING PERIODS3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Procedure Approved by J. Malm at PI 7.5.1-12 G - WF ID -475701883100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001PCD PI 7.5.1-12 Rev inch I inch on WF519752543100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170PI-022, REV D3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101PI-022, REV D3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PI 7.5.1-11 Rev. B3100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
001545123HI-TECH METALS, INC.010569251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010PI-0093100 JIM CHRISTAL RDDENTONTX762072600Frank SaenzQA Manager(940)243-0516
008357295HIXSON METAL FINISHINGR08433,PQA392,08433200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433200CANODIZEHard AnodizeMIL-A-8625, Type III 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433200SANODIZEChromic Acid Anodize2ZZP00001 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD number HPS 200.5, revision A.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G63930 minute minimum air dry followed by 140-180F cure only. Curing requiring humidity excluded. Approved PCD HPS 2500.6, revision A. Excludes applications requiring Biocidal Dye.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 listed source for pre-penetrant etching.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved procedures HPS 2200 Rev. AH and HPS 2200.5 Rev. C. Must use QCS-001 source for etching of materials other that aluminum and for castings.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201F/D Critical Approval Expiration/Re-qualification Date 04/30/2019.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433240APAINT and PRIMEPrime and PaintMIL-F-18264 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Reviewed/approved procedure HPS 2500, Revision Q.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433230APLATINGCadmiumQQ-P-416 Type I 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433230BPLATINGCadmiumQQ-P-416 Type II 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433230CPLATINGCadmiumQQ-P-416 Type III 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433234APLATINGElectroless NickelMIL-C-26074, Class 1 / (AMS 2404 Class 1 effective 01-01-2014)Low phosphoruous only per AMS 2404.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433234BPLATINGElectroless NickelMIL-C-26074, Class 2 (AMS 2404 Class 2 effective 01-01-2014)Low phosphoruous only per AMS 2404.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433234CPLATINGElectroless NickelMIL-C-26074, Class 3 (AMS 2404 Class 3 effective 01-01-201Low phosphoruous only per AMS 2404.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433234DPLATINGElectroless NickelMIL-C-26074, Class 4 (AMS 2404 Class 4 effective 01-01-2014Low phosphoruous only per AMS 2404.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433235APLATINGNickelQQ-N-290, Class 1 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433235BPLATINGNickelQQ-N-290, Class 2 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Aluminum only. Excludes castings. Approved procedure HPS 2100.4, revision M.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD: HPS 2100.9 Rev. C.829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
008357295HIXSON METAL FINISHINGR08433,PQA392,08433251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 829 PRODUCTION PL.NEWPORT BEACHCA92663Jerome TrostQA Manager(949)722-3470
PMSPQA444HTA Aerospace and Defense Pty LtdPQA444167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 40B CAPITAL LINK DRIVECAMPBELLFIELD, VICTORIA203661Ian BowdenQA Manager(039)357-8393
PMSPQA444HTA Aerospace and Defense Pty LtdPQA444168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 40B CAPITAL LINK DRIVECAMPBELLFIELD, VICTORIA203661Ian BowdenQA Manager(039)357-8393
756865986HTA Aerospace and Defense Pty LtdPQA387168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 32 GAY STREETCOOPERS PLAINS, QUEENSLAN 4110Jon O'DonnellQA Manager 
PMSPQA444HTA Aerospace and Defense Pty LtdPQA444606HEAT TREATMENTSAluminumAMS-2770 40B CAPITAL LINK DRIVECAMPBELLFIELD, VICTORIA203661Ian BowdenQA Manager(039)357-8393
756865986HTA Aerospace and Defense Pty LtdPQA387609HEAT TREATMENTSSteelAMS-2759 32 GAY STREETCOOPERS PLAINS, QUEENSLAN 4110Jon O'DonnellQA Manager 
756865986HTA Aerospace and Defense Pty LtdPQA387609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3AGE ONLY32 GAY STREETCOOPERS PLAINS, QUEENSLAN 4110Jon O'DonnellQA Manager 
557046179HUDSON PLATING WORKSS07479,09691234APLATINGElectroless NickelMIL-C-26074, Class 1 / (AMS 2404 Class 1 effective 01-01-2014)Approved for High Phosphorus Content 10-12%11941 HERTZ AVEMOORPARKCA930217145Marcia HudsonQA Manager(805)517-1222
109082255HYDROFORM USA INCORPORATED008248,08150200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BType I only.Approvals Excluding processing to F-35 program / 2ZZP000012848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150200HANODIZEChromic Acid AnodizeSTP 58-209Type I only. 2XXX series aluminum only.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD MPP number 003, revision G.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150600BHEAT TREATMENTSAluminumSTP 54-101Solution and age only.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150606HEAT TREATMENTSAluminumAMS-2770 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150240APAINT and PRIMEPrime and PaintMIL-F-18264 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014)Excludes MIL-PRF-83285 material.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD MPP-001, revision J.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150404CWELDINGResistance WeldingSTP 55-005Spot Welding Only. Approved cleaning PCD MPP-001, Revision J.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
109082255HYDROFORM USA INCORPORATED008248,08150413WELDINGResistance Welding for Aerospace ApplicationsAWS D17.2 (Approval required by 01-01-2014)Spot welding only.2848 E 208TH STCARSONCA908101101Jeff RichardQA Manager 
PMSPQA421IAI - RAMTA DIVISIONPQA421911BONDING AND COMPOSITESVertical Stabilizer AssemblyFPS-3557 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=15689121%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. IZHAK NAFCHA 1 STREET, POB 323, BEER SHEVAISRAEL 84102Lior TalmaonQA Manager 
PMSPQA421IAI - RAMTA DIVISIONPQA421919NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonding and CompositesNDTS-5103 IZHAK NAFCHA 1 STREET, POB 323, BEER SHEVAISRAEL 84102Lior TalmaonQA Manager 
SAPPQA996IAI ENGINEERINGPQA996110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Limitation: Portable FPI, for MRB activities, Not approved for etchingLODAIRPORT 7010000Mr. Dror Zarif (+972)QA Manager 
SAPPQA996IAI ENGINEERINGPQA996113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD PS810100E and LMA 001 rev New / WF 47631555 Limitation: Portable / MRB, No Etch approvalLODAIRPORT 7010000Mr. Dror Zarif (+972)QA Manager 
SAPPQA996IAI ENGINEERINGPQA996113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility qualification approval expires 10/31/2017LODAIRPORT 7010000Mr. Dror Zarif (+972)QA Manager 
SAPPQA996IAI ENGINEERINGPQA996134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Limitation: MRB Activities. Approved TDA LMA 006 rev ALODAIRPORT 7010000Mr. Dror Zarif (+972)QA Manager 
SAPPQA996IAI ENGINEERINGPQA996139NON-DESTRUCTIVE TESTINGEddy CurrentLMA-PC002Limitation: MRB PCD PS810310E r B PS810300E r C / WF 47631332, TDS LMA 002, 003, 004, 005LODAIRPORT 7010000Mr. Dror Zarif (+972)QA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448600BHEAT TREATMENTSAluminumSTP 54-101 Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448606HEAT TREATMENTSAluminumAMS-2770 Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Limited to Degrease only per Danals/ NarowitzWoodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448401AWELDINGFusion WeldingSTP 55-104 Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
PMSPQA448INFLITE ENGINEERING SERVICESPQA448404CWELDINGResistance WeldingSTP 55-005 Woodside Industrial Estate Dunmow Road Bishops StortfordHertfordshire CM23 5RG  Rowshan RowshangoharQA Manager 
0257606IONIC TECHNOLOGIES, INC.PQA446609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 207 FAIRFOREST WAYGREENVILLESC29607Craig RawleyQA Manager(864)288-9111
0257606IONIC TECHNOLOGIES, INC.PQA446609HHEAT TREATMENTSSteel - Ion NitridingAMS 2759/8 207 FAIRFOREST WAYGREENVILLESC29607Craig RawleyQA Manager(864)288-9111
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026606HEAT TREATMENTSAluminumAMS-2770 NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
600539498ISRAEL AEROSPACE INDUSTRIES LTS02212110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Limitation: Portable FPI, for MRB activities, Not approved for etchingMILITARY AIRCRAFT GROUP LAHAVDIVISIONNO PHYSICAL ADDRESSLOD AIRPORT557010000Adi GalQA Manager 
600539498ISRAEL AEROSPACE INDUSTRIES LTS02212113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD PS810100E and LMA 001 rev New / WF 47631555 Limitation: Portable / MRB, No Etch approvalMILITARY AIRCRAFT GROUP LAHAVDIVISIONNO PHYSICAL ADDRESSLOD AIRPORT557010000Adi GalQA Manager 
600539498ISRAEL AEROSPACE INDUSTRIES LTS02212113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility qualification approval expires 10/31/2017MILITARY AIRCRAFT GROUP LAHAVDIVISIONNO PHYSICAL ADDRESSLOD AIRPORT557010000Adi GalQA Manager 
600539498ISRAEL AEROSPACE INDUSTRIES LTS02212134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Limitation: MRB Activities. Approved TDA LMA 006 rev AMILITARY AIRCRAFT GROUP LAHAVDIVISIONNO PHYSICAL ADDRESSLOD AIRPORT557010000Adi GalQA Manager 
600539498ISRAEL AEROSPACE INDUSTRIES LTS02212139NON-DESTRUCTIVE TESTINGEddy CurrentLMA-PC002Limitation: MRB PCD PS810310E r B PS810300E r C / WF 47631332, TDS LMA 002, 003, 004, 005MILITARY AIRCRAFT GROUP LAHAVDIVISIONNO PHYSICAL ADDRESSLOD AIRPORT557010000Adi GalQA Manager 
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026240APAINT and PRIMEPrime and PaintMIL-F-18264 NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
600539498ISRAEL AEROSPACE INDUSTRIES LTS02212240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 MILITARY AIRCRAFT GROUP LAHAVDIVISIONNO PHYSICAL ADDRESSLOD AIRPORT557010000Adi GalQA Manager 
600014609ISRAEL AEROSPACE INDUSTRIES LT482526,19026406DWELDINGFusionFPS-1095, Aluminum NO PHYSICAL ADDRESSAIRPORT CITY557019900Adi GalQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 TY IB - PCD: TI 033.22.27 rev NEWPRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984910BONDING AND COMPOSITESAdhesive Bonded AssembliesFPS-3016 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613934%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Limited to parts listed in FQPL-3016.PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984913BONDING AND COMPOSITESPlasticsFPS-3026 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613843%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Limited to parts listed in FQPL-3026.PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051PCD: TI053.22.03 rev T / WF 42385297PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Limitation: F-35 Brush Application only / F-16 immersionPRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984605AHEAT TREATMENTSSteelFPS-3014 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984606HEAT TREATMENTSAluminumAMS-2770 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.FQPL-NDTS-1101 PCIR 1696 and PCIR 1926PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.FQPL-NDTS-1101 PCIR 1926PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.FQPL-NDTS-1101 PCIR 1926PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD: QE-00-306-035 rev NEW / WF 52126228PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, F-35 Facility Re-qualification Due May 31, 2019PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984919NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonding and CompositesNDTS-5103 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984240APAINT and PRIMEPrime and PaintMIL-F-18264 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PCD: 039.22.0/2-F-16 rev T / WF ID 44416354PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD: TI 039.22.02-F35-AL rev New / WF 52126734PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984250ASOLID FILM LUBRICANTSSolid Film Lubricant - Solvent BaseFPS-3006 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614032%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Applicators: Moshayv Igor and Yashayv MichaelPRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
PMSPQA984ISRAEL AIRCRAFT INDUSTRIESPQA984406DWELDINGFusionFPS-1095, Aluminum PRODUCTION DIVISION BEN GURION INTERNATIONAL AIRPORTLOD, ISRAEL  Mr. Dan KleberQA Manager 
008496598JAN-KENSPQA454200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BExcludes Type 1.715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDES ZONES1A,1B, and 1C. Must use QCS-001 approved source for pre-penetrant etching of titanium and FE/NI based materials.715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454240APAINT and PRIMEPrime and PaintMIL-F-18264 715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
008496598JAN-KENSPQA454110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved procedure JK-PE-1, Rev. I.715 E. CYPRESSMONROVIACA91016Chris MarksQA Manager(626)358-1849
048493761JCM ENGINEERING CORP.S00627,16186240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 2690 E CEDAR STONTARIOCA917618533Brenda KaneQA Manager(909)923-3730
008318289JOSEFF-HOLLYWOOD100441512ACASTINGSFerrous CastingsSTP53-400PCD for STP53-400AV01 WF number 51743792129 E PROVIDENCIA AVEBURBANKCA915021922Tina JoseffQA Manager(818)846-0157
008318289JOSEFF-HOLLYWOOD100441512BCASTINGSNon-ferrous CastingsSTP53-400 129 E PROVIDENCIA AVEBURBANKCA915021922Tina JoseffQA Manager(818)846-0157
008304594K and L ANODIZING CORP.PQA467200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 1200 S. VICTORY BLVD. PO BOX 311BURBANKCA91503Dana SchlumpbergerQA Manager(818)845-7251
008304594K and L ANODIZING CORP.PQA467200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 1200 S. VICTORY BLVD. PO BOX 311BURBANKCA91503Dana SchlumpbergerQA Manager(818)845-7251
008304594K and L ANODIZING CORP.PQA467200CANODIZEHard AnodizeMIL-A-8625, Type III 1200 S. VICTORY BLVD. PO BOX 311BURBANKCA91503Dana SchlumpbergerQA Manager(818)845-7251
008304594K and L ANODIZING CORP.PQA467210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Excludes Type II, Class 1A.1200 S. VICTORY BLVD. PO BOX 311BURBANKCA91503Dana SchlumpbergerQA Manager(818)845-7251
356821111KALE HAVACILIK SANAYI ANONIM013143200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation: Type IB onlySIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143200CANODIZEHard AnodizeMIL-A-8625, Type III SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016KH-OPT-070 REV 1, May 5th 2008SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143606HEAT TREATMENTSAluminumAMS-2770 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143609HEAT TREATMENTSSteelAMS-2759 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007PCD: KNDT-M002 rev 1 / WF ID 52026426SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD: KNDT-P002 rev 5 / WF 54149099SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification Approval Expires March 31, 2018SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143240APAINT and PRIMEPrime and PaintMIL-F-18264 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Grandfathered / MIL-F-18264SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001KH-OPT-014 rev 1 / WF 41801690. No Localized Etching.SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001KH-OPT-020 rev 0 / WF 40025746. No Localized Etching.SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001KH-OPT-072 rev 4 / WF 40025754. No Localized Etching.SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
356821111KALE HAVACILIK SANAYI ANONIM013143251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 SIRKETIIST END VE TIC SERBEST BOLGESIISTANBUL (ANATOLIA)8534953Selim EROL (+90)QA Manager(902)165-8140
SAPPQA929KILGOUR METAL TREATMENTSPQA929110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 HOLLY CLOSE RED MARSH INDUSTRIAL ESTATECLEVELEYS FY5 4LR GB  Gordon NisbetQA Manager(125)386-4609
SAPPQA929KILGOUR METAL TREATMENTSPQA929111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 HOLLY CLOSE RED MARSH INDUSTRIAL ESTATECLEVELEYS FY5 4LR GB  Gordon NisbetQA Manager(125)386-4609
SAPPQA929KILGOUR METAL TREATMENTSPQA929615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011) HOLLY CLOSE RED MARSH INDUSTRIAL ESTATECLEVELEYS FY5 4LR GB  Gordon NisbetQA Manager(125)386-4609
730361318KONGSBERG DEFENCE and AEROSPACE012662831ABONDING AND COMPOSITESJSF BMI Fabrication2ZZP00002 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=27833214%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662832ABONDING AND COMPOSITESJSF Epoxy Fabrication2ZZP00004 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396622%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662840BONDING AND COMPOSITESJSF BONDING and COBONDING PARTS WITH EPOXY MATLS2ZZP00039 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18397315%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Final Approval will be based upon QPL listing by JSF M and P Procedure 3DOO60211396 Rev New Bldg 804 ti etch approved.USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662841BONDING AND COMPOSITESJSF BONDING and COBONDING PARTS WITH BMI MATERIALS2ZZP00042 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18396679%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Fabrication of BMI Honeycomb Core Sandwich Parts - Qualification Report 2ZZA00857USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662602EHEAT TREATMENTSTitaniumAMS-2801Limitation: Stress Relief OnlyUSD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD KVS-8011 ed 3 / WF ID 51146161USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires Aug 31, 2018USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301PCD KVS-8008 edition 3 / WF ID 41035030USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662124NON-DESTRUCTIVE TESTINGDigital Detector Arrays (DDA)2ZZP00045PCD: A165554 rev - / WF 54346060USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001PCD UT TDS (P/N) / WF 38880951, 38880815, 38880926, 38880807, 38879384, 38879376, 38880911USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Grandfathered / MIL-F-18264USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001PCD 1D0060211396 rev C / WF 42279220USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662QPL05QPL CONTROLLED PROCESSESManufacture and QC of the JSF Upper Wing Skin2ZZP10000 - This is not a special process requiring monitoring or approval by Supplier Quality Management (SQM), however processors are limited to the qualified sources listed on the Qualified Processor List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=21915625%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D18397496%26objAction%3Dbrowse%26viewType%3D1)Cured laminate compensation - Qualification Report 2ZZA00857USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662402WELDINGElectron Beam WeldingAMS-2680 / AMS-2681 USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
730361318KONGSBERG DEFENCE and AEROSPACE012662402BWELDINGElectron Beam WeldingLMA-PE007 USD ACCTKIRKEGARDSVEIEN 45KONGSBERG753616Jan EggestadQA Manager(479)752-3055
688021559KOREA AEROSPACE INDUSTRIES LIM011640210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405PI-AS-05 Rev K. Conventional and special etch clean78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640243FUEL TANK COATINGSeal Bond Primer ApplicationFPS-3035 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613846%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640600BHEAT TREATMENTSAluminumSTP 54-101 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640606HEAT TREATMENTSAluminumAMS-2770 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes LCP72-1068.78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640240APAINT and PRIMEPrime and PaintMIL-F-18264 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
688021559KOREA AEROSPACE INDUSTRIES LIM011640619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD PI-AS-53, Revision J.78 GONGDAN1-RO, SANAM-MYEONSACHEON77525-290K.S. Kim [Resp. for Quality Perf.]QA Manager(055)851-1636
619009954KROPP FORGE CO.PQA473513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 5301 W. ROOSEVELT RD.CICEROIL60650Steve BorcikQA Manager(708)652-6691
619009954KROPP FORGE CO.PQA473169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 5301 W. ROOSEVELT RD.CICEROIL60650Steve BorcikQA Manager(708)652-6691
619009954KROPP FORGE CO.PQA473601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 5301 W. ROOSEVELT RD.CICEROIL60650Steve BorcikQA Manager(708)652-6691
619009954KROPP FORGE CO.PQA473100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 5301 W. ROOSEVELT RD.CICEROIL60650Steve BorcikQA Manager(708)652-6691
619009954KROPP FORGE CO.PQA473101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 5301 W. ROOSEVELT RD.CICEROIL60650Steve BorcikQA Manager(708)652-6691
201883845L-3 COMMUNICATIONS MAS (CANADA013789242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 10000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
201883845L-3 COMMUNICATIONS MAS (CANADA013789242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639 10000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
201883845L-3 COMMUNICATIONS MAS (CANADA013789170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)PCD Submitted on 11/10/2015, checklists verified by A Urrutia10000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
201883845L-3 COMMUNICATIONS MAS (CANADA013789600CHEAT TREATMENTSAluminumProcess Spec C-0521Approved by Weber AGE only 2024 and 707510000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
201883845L-3 COMMUNICATIONS MAS (CANADA013789606HEAT TREATMENTSAluminumAMS-2770 10000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
201883845L-3 COMMUNICATIONS MAS (CANADA013789244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014) 10000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
201883845L-3 COMMUNICATIONS MAS (CANADA013789248PAINT and PRIMETouch-Up Requirements for Finishes On P-3C-395-M (Effective 01-01-2014) 10000 RUE HELEN-BRISTOLMIRABEL20J7N 1H3Marie-Christine Desilets - QA DirQA Manager 
437302169L.M.A. LAVORAZIONE MECCANICAS02402,PQA994167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 AERONAUTICA SRL VIA VERCELLI 6PLANEZZA 10044Mr. Alessandro Puglisi (+39) (ext 105)QA Manager(119)672-053
437302169L.M.A. LAVORAZIONE MECCANICAS02402,PQA994168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009Limitation: Aluminum onlyAERONAUTICA SRL VIA VERCELLI 6PLANEZZA 10044Mr. Alessandro Puglisi (+39) (ext 105)QA Manager(119)672-053
437302169L.M.A. LAVORAZIONE MECCANICAS02402,PQA994240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 AERONAUTICA SRL VIA VERCELLI 6PLANEZZA 10044Mr. Alessandro Puglisi (+39) (ext 105)QA Manager(119)672-053
847999158LAI INTERNATIONAL, INC.006942168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 7645 BAKER ST NEMINNEAPOLISMN554323421Renee JohnsonQuality Engineer(763)780-0060
150884898LAKES REGION TUBULAR PRODUCTS,011002123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Limited to IN HOUSE use51 GROWTH RDLACONIANH032461318Dan Douville Ext 24QA Manager(603)528-2838
150884898LAKES REGION TUBULAR PRODUCTS,011002408AWELDINGFUSION WELDING - F-352ZZP00013Approved PCD for pre-weld cleaning 7500W030 Revision 4 (WF 53403592)51 GROWTH RDLACONIANH032461318Dan Douville Ext 24QA Manager(603)528-2838
064730294LAWRENCE RIPAK CO.S15010,PQA486200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimited to 22 Volts only165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486200UANODIZEBoric Sulfuric Anodize5PTPHL23 / 5PTPHB20 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486205ACHEMICAL CONVERSION COATINGTitanium Fluoride-Phosphate Coating5PTPHG16LR-CHM-PP-29 rev M165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486206CHEMICAL CONVERSION COATINGTitanium Conversion CoatingAMS-2486 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Limitation: Class 1 only including Conventional and special etch clean165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016Phosphate Fluoride LR-CHM-PP-29 Rev. M / Chem film LR-CHM-PP-17(AH)165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources.Application of AMS-C-27725 Material Only165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486166HEAT TREAT VERIFICATIONHardness / Conductivity of Aluminum5PTPTL19 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007LR-MT-PP-2 rev AN165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Zone approvals 1A, 1b, 1C per PCIR 1777165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.LR-09-PP-Z001, Rev C, ZONE 1A, 1B, and 1C APPROVED. BY LMTAS LEVEL III165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.LR-09-PP-Z001, Rev C, ZONE 1A, 1B, and 1C APPROVED. BY LMTAS LEVEL III165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.LR-09-PP-Z001, Rev C, ZONE 1A, 1B, and 1C APPROVED. BY LMTAS LEVEL III165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486112ANON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02 Fracture Critical including Critical Hardware 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486112BNON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) Fracture Critical Dem Prog5PTPCL02 including Critical Hardware 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved for Non-Critical Parts and Critical Parts LR-09-PP-Z001, revision C165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Approval expires10/31/2019 LR-09-PP-Z001165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486136NON-DESTRUCTIVE TESTINGEddy Current5PTPCT02INCLUDES F-22 F and D CRITICAL165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486136ANON-DESTRUCTIVE TESTINGEddy Current5PTPCT02 Fracture Critical 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Approved for Non-Critical Parts and Critical Parts. LR-09-PP-Z001, Rev C165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486146ANON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06 Fracture CriticalApproved for Fracture Critical Parts, Facility Approval expires 10/31/2019165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486240APAINT and PRIMEPrime and PaintMIL-F-18264 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Rework allowed per LR-CHM-RW-2 Rev. B - WF ID -52526589165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486230APLATINGCadmiumQQ-P-416 Type I 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486230BPLATINGCadmiumQQ-P-416 Type II 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486230JPLATINGCadmium (P3 ONLY)C-0491LR-CHM-PP-21 rev AG / WF 38881087165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.LR-CHM-PP-23 REV T dated 9/4/2012165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486110C2PRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.LR-CHM-PP-31 revision W on 7/25/2014165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486146B1PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGG01LR-CHM-PP-23 REV V165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486146B2PRE-PENETRANT ETCHPre-Penetrant Etch - Titanium5PTPGG01LR-CHM-PP-31 revision W on 7/25/2014165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486146B5PRE-PENETRANT ETCHPre-Penetrant Etch - Titanium5PTPGL01LR-CHM-PP-31 revision W on 7/25/2014165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486146B6PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGL03LR-CHM-PP-23 REV V165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001LR-CHM-PP-23 REV V and LRCHMPP36 rev C (Local etch) - WF 36846820165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001LR-CHM-PP-31 revision W on 7/25/2014 and LRCHMPP36 rev C (Local etch) - WF 36846820165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)LR-CHM-PP-23 REV V165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170LR-CHM-PP-23 REV V165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301LR-CHM-PP-23 REV V165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486310ASHOT PEENINGShot PeeningMIL-S-13165/AMS-S-13165 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486310BSHOT PEENINGShot PeeningFPS-1032 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486311SHOT PEENINGShot PeeningSTP51-501 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
064730294LAWRENCE RIPAK CO.S15010,PQA486255SOLID FILM LUBRICANTSSolid Film Lube5PTPMT02 165 FIELD STREETW. BABYLONNY117041416Alex KolkerQA Manager(631)694-1818
803865302LMI AEROSPACE - CUBAPQA635200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635200LANODIZESulfuric Acid AnodizeSTP 58-208PCP STP58-208 revision B dated 09-2014109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405class 1 only PCP STP58-405 rev B. 9-22-2015109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PCP-C-0498 rev A 2-14-2013109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639PCP 505-G639- rev B 4-21-2014109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDE ZONES 1A, 1B, 1C109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068STP-05.8.2.4. H rev M 10-19-2015109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567PCP-C-0567 rev A, 2-28-2013109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201STP-05.8.2.4. H rev M 10-19-15109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635240APAINT and PRIMEPrime and PaintMIL-F-18264 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)PCP-700-378 Rev A109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PCP-NDTS-1101 Rev B. 8-10-2012109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCP-LMA-PG001D, 10-16-13109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170PCP-C-0170 rev B 3/20/2013109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
803865302LMI AEROSPACE - CUBAPQA635619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCP-STP57-301 Rev C 6-30-2011109 MIDLAND DR. PO BOX 680CUBAMO65453Tim RenfroeQA Manager(636)544-0447
041157876LUBECO, INCPQA505200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505200CANODIZEHard AnodizeMIL-A-8625, Type III 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505206CHEMICAL CONVERSION COATINGTitanium Conversion CoatingAMS-2486 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505240APAINT and PRIMEPrime and PaintMIL-F-18264 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505250ASOLID FILM LUBRICANTSSolid Film Lubricant - Solvent BaseFPS-3006 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614032%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Approved applicators S. Rossi, A. Agredano and J. Valenzuela for Lubeco M3906859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505250A1SOLID FILM LUBRICANTSSOLID FILM LUBRICANTS - WATER BASEFPS-3006 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614032%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Approved applicators S. Rossi, A. Agredano, J. Valenzuela and R. Wheeler for everlube 90026859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
041157876LUBECO, INCPQA505251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 6859 DOWNEYLONG BEACHCA90805Charles HawkinsQA Manager(562)602-1791
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405NO CLASS 2 Processing5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597600BHEAT TREATMENTSAluminumSTP 54-101 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597606HEAT TREATMENTSAluminumAMS-2770 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597240APAINT and PRIMEPrime and PaintMIL-F-18264 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
085502685M2 GLOBAL TECHNOLOGY, LTD.011928,24597247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 5714 EPSILONSAN ANTONIOTX782493407Wayne RichieQA Manager(210)561-4885
799876123MAGELLAN AEROSPACE, GLENDALE, INC101220,PQA641512BCASTINGSNon-ferrous CastingsSTP53-400Aluminum5401 W LUKE AVEP O BOX 1059GLENDALEAZ85311Leticia MunozQA Manager(623)939-9441
799876123MAGELLAN AEROSPACE, GLENDALE, INC101220,PQA641607HEAT TREATMENTSAluminum CastingsAMS-2771 5401 W LUKE AVEP O BOX 1059GLENDALEAZ85311Leticia MunozQA Manager(623)939-9441
799876123MAGELLAN AEROSPACE, GLENDALE, INC101220,PQA641120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 5401 W LUKE AVEP O BOX 1059GLENDALEAZ85311Leticia MunozQA Manager(623)939-9441
799876123MAGELLAN AEROSPACE, GLENDALE, INC101220,PQA641121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301WI 7-4 RT5401 W LUKE AVEP O BOX 1059GLENDALEAZ85311Leticia MunozQA Manager(623)939-9441
799876123MAGELLAN AEROSPACE, GLENDALE, INC101220,PQA641406GWELDINGWeld Repair of CastingsSTP-55-801Approved welders employee number 4717, 5318, 5334.+ Dave Manship5401 W LUKE AVEP O BOX 1059GLENDALEAZ85311Leticia MunozQA Manager(623)939-9441
008474637MAGNESIUM ALLOY PRODUCTS COMPA100333,10383512BCASTINGSNon-ferrous CastingsSTP53-400 INC.2420 N ALAMEDA STCOMPTONCA902222895Victor De GandiagaQA Manager(310)605-1440
008474637MAGNESIUM ALLOY PRODUCTS COMPA100333,10383169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness onlyINC.2420 N ALAMEDA STCOMPTONCA902222895Victor De GandiagaQA Manager(310)605-1440
008474637MAGNESIUM ALLOY PRODUCTS COMPA100333,10383607HEAT TREATMENTSAluminum CastingsAMS-2771Age Only.INC.2420 N ALAMEDA STCOMPTONCA902222895Victor De GandiagaQA Manager(310)605-1440
068451533MAGNETIC INSPECTION LABSPQA526200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BNo processing of F-35 Parts1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526200CANODIZEHard AnodizeMIL-A-8625, Type III 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526200HANODIZEChromic Acid AnodizeSTP 58-209 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526200LANODIZESulfuric Acid AnodizeSTP 58-20823.MF.12-LOC Rev 41401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526200P1ANODIZEHard AnodizePS0445 Hard Anodizing of Aluminum Alloys 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526305CHEM MILLING / DESCALINGChemical MillingPS 0450 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Conventional/Special Etch 22.MF.50-LOC Rev 31401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.44.N.20 R151401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526230APLATINGCadmiumQQ-P-416 Type I 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526230BPLATINGCadmiumQQ-P-416 Type II 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526230CPLATINGCadmiumQQ-P-416 Type III 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526230HPLATINGCadmiumSTP 58-001 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.22.MF.50-LOC Rev 31401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)22.MF.50-LOC Rev 31401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-10122.MF.50-LOC Rev 31401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-30122.MF.50-LOC Rev 31401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
068451533MAGNETIC INSPECTION LABSPQA526401AWELDINGFusion WeldingSTP 55-104 1401 GREENLEAF AVE.ELK GROVEIL600075522James BrinkerQA Manager(847)437-4488
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BNot approved to process F35 hardwareLIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354200HANODIZEChromic Acid AnodizeSTP 58-209Limit TY 1 only. PCD: 16-02-I0033-06-PT011 Is 5/WF 52127879LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354200LANODIZESulfuric Acid AnodizeSTP 58-208PCD: 16-02-I0033-06-PT030 Is 6/WF 52126560LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354200P1ANODIZEHard AnodizePS0445 Hard Anodizing of Aluminum AlloysTDA 55020LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Limited to TY 1A CL 1 only. PCD: PCFC-06-PT013 Issue 1LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354600BHEAT TREATMENTSAluminumSTP 54-101 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354606HEAT TREATMENTSAluminumAMS-2770 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011) LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCFC-06-PT012 Issue 4LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354401AWELDINGFusion WeldingSTP 55-104 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
218083210MARSHALL OF CAMBRIDGE AEROSPAC100354401DWELDINGFusion WeldingAWS D17.1 LIMITEDAIRPORT HOUSECAMBRIDGE30CB5 8RYHanif NabiQA Manager 
119578347MARYLAND QC LABORATORIESPQA527120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 1550 S. PHILADELPHIA BLVDABERDEENMD21001Gary BaldwinQA Manager(410)575-7295
119578347MARYLAND QC LABORATORIESPQA527123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301MQC-RT-2 Rev 71550 S. PHILADELPHIA BLVDABERDEENMD21001Gary BaldwinQA Manager(410)575-7295
119578347MARYLAND QC LABORATORIESPQA527124NON-DESTRUCTIVE TESTINGDigital Detector Arrays (DDA)2ZZP00045MQC DRI-1 Rev 1 dated 8/24/151550 S. PHILADELPHIA BLVDABERDEENMD21001Gary BaldwinQA Manager(410)575-7295
849771977MATRIX COMPOSITES, INC.011570,23435807BBONDING AND COMPOSITESF-22 RTM - BMI5PTPLT13 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14620860%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440034%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 275 BARNES BLVDROCKLEDGEFL329555325Tim MurphyQA Manager(321)633-4480
849771977MATRIX COMPOSITES, INC.011570,23435240APAINT and PRIMEPrime and PaintMIL-F-18264 275 BARNES BLVDROCKLEDGEFL329555325Tim MurphyQA Manager(321)633-4480
007168685MAY TOOL AND MOLD CO., INC.002183240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 2922 WHEELING AVEKANSAS CITYMO641291100Al StimacQA Manager(816)923-6262
120258579MAYNARD, INC.013763240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 7175 S MCGUIRE STFAYETTEVILLEAR727045237Fred MaplesQA Manager(479)443-6677
002183630MCWILLIAMS FORGE COMPANY594492514FORGINGSForgingLMA-PA041 387 FRANKLIN AVEROCKAWAYNJ078664014Joe PascoeQA Manager(973)627-0200
002183630MCWILLIAMS FORGE COMPANY594492602HEAT TREATMENTSTitaniumAMS-H-81200Limitation Air Quench/Blast Only387 FRANKLIN AVEROCKAWAYNJ078664014Joe PascoeQA Manager(973)627-0200
602508202METAL IMPROVEMENT CO.PQA570310SHOT PEENINGShot PeeningAMS 2430 2151 S. HATHAWAY ST.SANTA ANACA92705Raul GonzalezQA Manager(714)546-4160
969172691METAL IMPROVEMENT CO.PQA528310SHOT PEENINGShot PeeningAMS 2430NO POST SHOT PEENING CHEMICAL CLEANING2588-A INDUSTRY WAYLYNWOODCA90262Linda MedinaQuality Engineer Manager(323)585-2168
602508202METAL IMPROVEMENT CO.PQA570310ASHOT PEENINGShot PeeningMIL-S-13165/AMS-S-13165No in house Cleaning2151 S. HATHAWAY ST.SANTA ANACA92705Raul GonzalezQA Manager(714)546-4160
087603262METAL IMPROVEMENT CO.600511,S11489,PQA544310ASHOT PEENINGShot PeeningMIL-S-13165/AMS-S-13165No chemical pre/post cleaning available, all precleaning must be done by a QCS-001 qualified source.1450 AVENUE, S. (F-70L)GRAND PRAIRIETX75050Jose CruzQA Manager(972)641-8011
602508202METAL IMPROVEMENT CO.PQA570310BSHOT PEENINGShot PeeningFPS-1032No in house Cleaning2151 S. HATHAWAY ST.SANTA ANACA92705Raul GonzalezQA Manager(714)546-4160
087603262METAL IMPROVEMENT CO.600511,S11489,PQA544310BSHOT PEENINGShot PeeningFPS-1032Post treat for AL,TI and CRES per para 3.9.1.1,2 must be performed by apprd QCS-001 source1450 AVENUE, S. (F-70L)GRAND PRAIRIETX75050Jose CruzQA Manager(972)641-8011
969172691METAL IMPROVEMENT CO.PQA528311SHOT PEENINGShot PeeningSTP51-501TYPES I and VI. NO POST PEENING CHEMICAL PROCESSING CAPABILITIES.2588-A INDUSTRY WAYLYNWOODCA90262Linda MedinaQuality Engineer Manager(323)585-2168
602508202METAL IMPROVEMENT CO.PQA570311SHOT PEENINGShot PeeningSTP51-501No in house Cleaning2151 S. HATHAWAY ST.SANTA ANACA92705Raul GonzalezQA Manager(714)546-4160
087603262METAL IMPROVEMENT CO.600511,S11489,PQA544311SHOT PEENINGShot PeeningSTP51-501ONLY P-D-680 CLEANING MATERIALAVAILABLE. PRECLEANING MUST BEDONE BY APPROVED QCS001 SOURCE1450 AVENUE, S. (F-70L)GRAND PRAIRIETX75050Jose CruzQA Manager(972)641-8011
087603262METAL IMPROVEMENT CO.600511,S11489,PQA544314SHOT PEENINGShot PeeningPS C-1476ONLY P-D-680 CLEANING MATERIALAVAILABLE. PRECLEANING MUST BEDONE BY APPROVED QCS001 SOURCE1450 AVENUE, S. (F-70L)GRAND PRAIRIETX75050Jose CruzQA Manager(972)641-8011
602508202METAL IMPROVEMENT CO.PQA570314SHOT PEENINGShot PeeningPS C-1476Approved PCD. QS 5.2.1-1 Rev1. No in house Cleaning.2151 S. HATHAWAY ST.SANTA ANACA92705Raul GonzalezQA Manager(714)546-4160
969172691METAL IMPROVEMENT CO.PQA528314SHOT PEENINGShot PeeningPS C-1476Approved PCD QS5.2.1-1 Rev. 0.2588-A INDUSTRY WAYLYNWOODCA90262Linda MedinaQuality Engineer Manager(323)585-2168
008283111METAL IMPROVEMENT COMPANYR02425,PQA531,02425310SHOT PEENINGShot PeeningAMS 2430NO POST SHOT PEENING CHEMICAL CLEANING CAPABILITIES.BEMCO FEEDING PLANT 3239 EAST 46TH STREETVERNONCA90058Armando YanezQuality Engineer Manager(323)585-2168
008283111METAL IMPROVEMENT COMPANYR02425,PQA531,02425311SHOT PEENINGShot PeeningSTP51-501NO POST SHOT PEENING CHEMICAL CLEANINGBEMCO FEEDING PLANT 3239 EAST 46TH STREETVERNONCA90058Armando YanezQuality Engineer Manager(323)585-2168
008283111METAL IMPROVEMENT COMPANYR02425,PQA531,02425314SHOT PEENINGShot PeeningPS C-1476NO POST SHOT PEENING CHEM. CLEANING. PCD: QS 5.2.1-1Rev.0 7/15/09 (WF ID-41371761)BEMCO FEEDING PLANT 3239 EAST 46TH STREETVERNONCA90058Armando YanezQuality Engineer Manager(323)585-2168
123866985METAL IMPROVEMENT COMPANY, INCPQA568310SHOT PEENINGShot PeeningAMS 2430 440 N WEST ROADWELLINGTONKS671528047Randy BloxsomQA Manager(620)326-5509
123866985METAL IMPROVEMENT COMPANY, INCPQA568311SHOT PEENINGShot PeeningSTP51-501Supplier is not capable to post clean shot peened parts440 N WEST ROADWELLINGTONKS671528047Randy BloxsomQA Manager(620)326-5509
123866985METAL IMPROVEMENT COMPANY, INCPQA568314SHOT PEENINGShot PeeningPS C-1476QP 7.5.1/ 3-11-2008-Supplier is not capable to post clean shot peened parts440 N WEST ROADWELLINGTONKS671528047Randy BloxsomQA Manager(620)326-5509
SAPPQA301METAL IMPROVEMENT COMPANY, SURPQA301315SHOT PEENINGLaser PeeningAMS2546 7655 LONGARD ROADLIVERMORECA94551Randy JonesQA Manager(925)960-1090
PMSPQA904METAL SPRAY CONCEPTS LLCPQA904310SHOT PEENINGShot PeeningAMS 2430 1 INDUSTRIAL DRIVEST. JAMESMO65559Brian WorsleyQA Manager(573)265-1017
PMSPQA904METAL SPRAY CONCEPTS LLCPQA904311SHOT PEENINGShot PeeningSTP51-501peen forming / saturation peen no post shot peen clean1 INDUSTRIAL DRIVEST. JAMESMO65559Brian WorsleyQA Manager(573)265-1017
242250637METCOR INC.PQA450170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)P900-05-EN- Rev 14560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
242250637METCOR INC.PQA450601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
242250637METCOR INC.PQA450601BHEAT TREATMENTSSteelSTP 54-006, Above 220 KSIExcludes Aermet 100 and AF 1410 materials560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
242250637METCOR INC.PQA450609HEAT TREATMENTSSteelAMS-2759 560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
242250637METCOR INC.PQA450609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
242250637METCOR INC.PQA450609BHEAT TREATMENTSSteel - Low Alloy GT220 ksiAMS 2759/2 560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
242250637METCOR INC.PQA450613HEAT TREATMENTSHeat Treatment of Steel Parts for AircraftC-0522P-000-29 Rev 01560 BOUL. ARTHUR-SAUVE ST. EUSTACHE, QUEBECJ7R 5A8  Costin-Sorin IonescuQA Manager(450)473-1884
379784234METTIS AEROSPACE LTDPQA405513BFORGINGSNon-ferrous ForgingsLAC-0562 This code is inactive use 513F. WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405513FFORGINGSNon-Ferrous ForgingsSTP51-320 - replaced LAC 0562 WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405162FRACTURE TOUGHNESS TESTINGFracture Toughness TestingASTM-E-399 WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
379784234METTIS AEROSPACE LTDPQA405130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 WINDSOR ROAD REDDITCHENGLAND, B97 6EF  Kevin WoodbineQA Manager 
PMSPQA548MIKRON MUHENDISLIKPQA548230BPLATINGCadmiumQQ-P-416 Type II AGAC ISLERI SANAYI SITESI 1376 SOKAK NO. 28 OSTIMANKARA8511111Didem Ozmen (+90)QA Manager(312)394-4787
PMSPQA548MIKRON MUHENDISLIKPQA548234APLATINGElectroless NickelMIL-C-26074, Class 1 / (AMS 2404 Class 1 effective 01-01-2014)Phosphorous Concentration - 10.5 -13.0 %AGAC ISLERI SANAYI SITESI 1376 SOKAK NO. 28 OSTIMANKARA8511111Didem Ozmen (+90)QA Manager(312)394-4787
PMSPQA548MIKRON MUHENDISLIKPQA548234BPLATINGElectroless NickelMIL-C-26074, Class 2 (AMS 2404 Class 2 effective 01-01-2014)Phosphorous Concentration - 10.5 -13.0 %AGAC ISLERI SANAYI SITESI 1376 SOKAK NO. 28 OSTIMANKARA8511111Didem Ozmen (+90)QA Manager(312)394-4787
027897164MISTRAS SERVICES101426,PQA360,23722100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
PMSPQA703MISTRAS SERVICESPQA703100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 915 ST. CHARLES ST.LAMBERT, QUEBECCANADA J402A2  David HughesQA Manager(450)671-0220
027897164MISTRAS SERVICES101426,PQA360,23722101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
PMSPQA703MISTRAS SERVICESPQA703101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 915 ST. CHARLES ST.LAMBERT, QUEBECCANADA J402A2  David HughesQA Manager(450)671-0220
027897164MISTRAS SERVICES101426,PQA360,23722110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
PMSPQA703MISTRAS SERVICESPQA703110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 915 ST. CHARLES ST.LAMBERT, QUEBECCANADA J402A2  David HughesQA Manager(450)671-0220
027897164MISTRAS SERVICES101426,PQA360,23722110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C. Must utilize QCS-001 source for pre-penetrant etching8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
027897164MISTRAS SERVICES101426,PQA360,23722111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
PMSPQA703MISTRAS SERVICESPQA703111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Limited NDI only, no LM pre-penetrant etch approval915 ST. CHARLES ST.LAMBERT, QUEBECCANADA J402A2  David HughesQA Manager(450)671-0220
027897164MISTRAS SERVICES101426,PQA360,23722111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD 587-SP-102B, Supp. C-0567 dated 06/14/2012. Must use a QCS-001 approved processor for pre-penetrant etching.8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
PMSPQA703MISTRAS SERVICESPQA703111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Rev. 0 Approved, Limited NDI only, no LM pre-penetrant etch approval915 ST. CHARLES ST.LAMBERT, QUEBECCANADA J402A2  David HughesQA Manager(450)671-0220
027897164MISTRAS SERVICES101426,PQA360,23722120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
027897164MISTRAS SERVICES101426,PQA360,23722121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved PCD 587-SP-301B Rev. 18427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
027897164MISTRAS SERVICES101426,PQA360,23722130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
027897164MISTRAS SERVICES101426,PQA360,23722619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD 587-SP-602 Rev. 2 and Supplement 587-STP57-301 N/C.8427 ATLANTIC AVE.CUDAHYCA90201Greg BolducQA Manager(323)583-1653
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478102NON-DESTRUCTIVE TESTINGMagnetic Particle Inspection5PTPCL01APPROVED FOR F-22 F/D CRITICAL.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478102ANON-DESTRUCTIVE TESTINGMagnetic Particle Inspection5PTPCL01 Fracture Critical 7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007Approved Procedure ML-200-1 Rev. Z, dated 3/7/2013.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.EXCLUDES ZONES 1A,1B, and 1C. Must use QCS-001 approved source for pre-penetrant etching.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Must use QCS-001 approved source for pre-penetrant etch.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02Must use QCS-001 approved source for pre-penetrant etch.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478112ANON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02 Fracture Critical including Critical HardwareAPPROVED FOR F-22 F/D CRITICAL.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478112BNON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) Fracture Critical Dem Prog5PTPCL02 including Critical HardwareMust use QCS-001 approved source for pre-penetrant etch. Approved procedure ML-300-37 Rev. N/C 10/31/2001.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Must use QCS-001 approved source for pre-penetrant etch. Approved for Non-Critical Parts and Critical Parts. Approved procedure ML-300-38 Rev. D, dated 03/05/2013.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 11/30/2018.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478130BNON-DESTRUCTIVE TESTINGUltrasonic InspectionNDTS-5101 7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478132BNON-DESTRUCTIVE TESTINGUltrasonic Inspection5PTPCT01Approved procedure ML-100-143, revision C.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478134NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonded and Composite StructLMA-PC001Approved procedure ML-100-172, Rev. B, dated 03/15/2013.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478142NON-DESTRUCTIVE TESTINGUltrasonic Inspection5PTPCG08Approved procedure MLUP-LFWC-002, revision A.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06Must use QCS-001 approved source for pre-penetrant etch. Approved for Non-Critical Parts and Critical Parts. Approved procedure ML-300-31F, 11/9/06.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
067793158MITCHELL LABORATORIES, INC.S02190,PQA554,02478146ANON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06 Fracture CriticalApproved for Fracture Critical Parts, Facility Qualification approval expires 11/30/2018.7707 BEQUETTE ST.PICO RIVERACA90660Cecilia PachecoQA Manager(562)949-6144
008488694MORRELLS ELECTROPLATING CO.012629,PQA558200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558200HANODIZEChromic Acid AnodizeSTP 58-209 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558200LANODIZESulfuric Acid AnodizeSTP 58-208Approved PCD: MPP number 58208L Rev. Org (WF ID 45018832)432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405Approved PCD MPP 0007L Rev. E432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498Approved PCD MPP 0498 Rev. A432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639Approved PCD MPP number 0004L Supp. 1 Rev. B432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417Steve Senne Level III432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1B and 1C432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.REFERENCE FQPL-NDTS1101 FOR SPECIFIC MATERIALS. PCIR 1736.432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes Titanium Castings.432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567Approved PCD: MPP 0567 Rev. A432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved for Non-Critical Parts and Critical Parts. Not Approved For Fracture Critical. M and P F-35 procedure number LMA-PC201 dated 03/14/10432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification Expires August 31, 2018432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558240APAINT and PRIMEPrime and PaintMIL-F-18264 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)MPPC378MC 5/24/2016432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD MPP 1102 Rev. C (WF-ID 46180894)432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001Approved PCD (aluminum only): MPP-051 Rev C dated 7/9/10 approved on WF-ID 36349011.432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170Aluminum only. Approved PCD MPP C0170 Rev. Org.432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
008488694MORRELLS ELECTROPLATING CO.012629,PQA558619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Approved PCD MPP 57301 Rev. Org. APPROVED BY M and P KEN DANALS ON 9/15/09 (WF ID 33624558432 EUCLID AVENUE P.O. BOX 3085COMPTONCA902222810Lin RiddleQA Manager(310)780-2371
220688445NASMYTH TECHNOLOGIES LIMITED013190210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Limitation: Type 1 Class 1A only78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PCD: PWSMP004 rev F (WF ID 40737501)78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)PCD: P-757 rev B / WF 5462484178-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190600CHEAT TREATMENTSAluminumProcess Spec C-0521PCD: WI-760-205-004 rev A / WF 5462449778-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190606HEAT TREATMENTSAluminumAMS-2770PCD: WI-760-205-004 rev A / WF 5462449778-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068STP53-201 approved only / Excludes LCP72-106878-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190111CNON-DESTRUCTIVE TESTINGPenetrant InspectionC-0567PCD: SP006 issue 5 (WF ID 45805497)78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190616PRE-PENETRANT ETCHCleaning-Alkaline/Acid Metal Remova lMethods OnlyC-0170PCD: PWSMP001 r E, PWS MP003 r F, PWS MP014 r F (WF 42026692), PWSMP007 r N (WF 47327695)78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101PCD: PWSMP003 rev F and PWS MP014 rev F (WF ID 42026692)78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190401AWELDINGFusion WeldingSTP 55-104 78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
220688445NASMYTH TECHNOLOGIES LIMITED013190404EWELDINGResistance WeldingC-1421PCD: PWSMP008 rev J and PWSMP008 Addendum 1 (WF 44590839)78-82 COBHAM ROADWIMBORNE30BH21 7RWMr. Richard Pavey (UK+44)QA Manager(120)289-5080
157704735NATIONAL PEENINGPQA619310SHOT PEENINGShot PeeningAMS 2430NO POST SHOT PEENING CHEMICAL CLEANING1902 WEINIG STSTATESVILLENC28677Chuck AnastasQA Manager(704)872-0113
157704735NATIONAL PEENINGPQA619310ASHOT PEENINGShot PeeningMIL-S-13165/AMS-S-13165NO POST SHOT PEENING CHEMICAL CLEANING1902 WEINIG STSTATESVILLENC28677Chuck AnastasQA Manager(704)872-0113
157704735NATIONAL PEENINGPQA619311SHOT PEENINGShot PeeningSTP51-501NO POST SHOT PEENING CHEMICAL CLEANING1902 WEINIG STSTATESVILLENC28677Chuck AnastasQA Manager(704)872-0113
157704735NATIONAL PEENINGPQA619314SHOT PEENINGShot PeeningPS C-1476PCD LM-0001 Rev New and WI 309-16 Rev A per WF ID -398309861902 WEINIG STSTATESVILLENC28677Chuck AnastasQA Manager(704)872-0113
064243009NDE, INC.649428,PQA613100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444PCD NTP-M issue 23 am 11189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101PCD NTP-M issue 23 am 11189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001PCD NTP-M issue 23 am 11189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007PCD NTP-M issue 23 am 11189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.NT-P issue 23 9/23/20091189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.NT-P issue 23 9/23/20091189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.NT-P issue 23 9/23/20091189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved procedure NTP-P, Issue 23. Approved for Fracture Critical Hardware.1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Per Fred Erlich approval for fracture critical is granted through3/31/20191189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613130BNON-DESTRUCTIVE TESTINGUltrasonic InspectionNDTS-5101 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613142NON-DESTRUCTIVE TESTINGUltrasonic Inspection5PTPCG08 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613163NON-DESTRUCTIVE TESTINGEddy CurrentNDTS-1601 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613919NON-DESTRUCTIVE TESTINGUltrasonic Inspection of Bonding and CompositesNDTS-5103 1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.PCD- NDE NTP-PPE Issue 15 January 19th of 20101189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
064243009NDE, INC.649428,PQA613148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD- NDE NTP-PPE Issue 15 January 19th of 2010 .1189 MERCEDES ST. (F-87L)BENBROOKTX76126Wes StricklandQA Manager 
008278525NEILL AIRCRAFT CO.649934,12376160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1260 W 15TH STLONG BEACHCA908131390Antonio AbeytaQA Manager(562)432-7981
008278525NEILL AIRCRAFT CO.649934,12376161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1260 W 15TH STLONG BEACHCA908131390Antonio AbeytaQA Manager(562)432-7981
008278525NEILL AIRCRAFT CO.649934,12376169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1260 W 15TH STLONG BEACHCA908131390Antonio AbeytaQA Manager(562)432-7981
008278525NEILL AIRCRAFT CO.649934,12376171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 1260 W 15TH STLONG BEACHCA908131390Antonio AbeytaQA Manager(562)432-7981
175091495NET SHAPES, INC.100198,23890512ACASTINGSFerrous CastingsSTP53-400INVESTMENT CASTINGS - FERROUS,BERYLLIUM, BRASS/BRONZE1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890512BCASTINGSNon-ferrous CastingsSTP53-400 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Excludes Conductivity1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890601GHEAT TREATMENTSCorrosion Resistant SteelsSTP 54-013 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Limited to STP53-201.1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301PCD OP 840 Rev. I (WF ID -44361812)1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
175091495NET SHAPES, INC.100198,23890406GWELDINGWeld Repair of CastingsSTP-55-801Approved Welders: Gonzalo Hernandez and Jose Perez1336 E FRANCIS ST STE BONTARIOCA917615723Richard WitherspoonQA Manager(909)947-3231
052403078NEWTON HEAT TREATING CO.PQA586160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586170HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthsC-0566 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Approved PCD: WI 3801 Rev. B (WF-ID 41565365)19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586600AHEAT TREATMENTSAluminumAMS-2772 (supersedes Mil-H-6088/AMS-H-6088) 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586600BHEAT TREATMENTSAluminumSTP 54-101 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586600CHEAT TREATMENTSAluminumProcess Spec C-0521Approved PCD: 3008 Rev. Org ( WF ID 45124905)19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
052403078NEWTON HEAT TREATING CO.PQA586606HEAT TREATMENTSAluminumAMS-2770 19235 E. WALNUT DR.CITY OF INDUSTRYCA91748Joe OsequeraQA Manager(626)964-6528
082833732NOR-RAL, INC.100200,02389820BONDING AND COMPOSITESFabrication of Glass Fabric Base, Epoxy Resin, L/PSTP61-213 164 HICKORY SPRNG IND DRCANTONGA301157927Ken Forest x221QA Manager(770)720-0526
082833732NOR-RAL, INC.100200,02389822BONDING AND COMPOSITESFabrication of Aramid Fiber Epoxy Resin LaminateSTP60-207 164 HICKORY SPRNG IND DRCANTONGA301157927Ken Forest x221QA Manager(770)720-0526
082833732NOR-RAL, INC.100200,02389833BONDING AND COMPOSITESComposite Parts Surveillance and QualificationLMA-D0010 164 HICKORY SPRNG IND DRCANTONGA301157927Ken Forest x221QA Manager(770)720-0526
082833732NOR-RAL, INC.100200,02389844BONDING AND COMPOSITESFABRICATION OF EPOXY FOR C-130 PROGRAMSTP61-2263364038-3/-4 part numbers only164 HICKORY SPRNG IND DRCANTONGA301157927Ken Forest x221QA Manager(770)720-0526
082833732NOR-RAL, INC.100200,02389246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 164 HICKORY SPRNG IND DRCANTONGA301157927Ken Forest x221QA Manager(770)720-0526
082833732NOR-RAL, INC.100200,02389247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 164 HICKORY SPRNG IND DRCANTONGA301157927Ken Forest x221QA Manager(770)720-0526
518799069NORWEGIAN COATING TECHNOLOGYPQA137240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 MERDEVEIEN 4BNOTODDEN, N-3676  Ms. Anja KristiansenQA Manager(479)098-8619
431752351O.M.P.M. SRLS02184,PQA598200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BLimitation TY IB, small and large tanksVIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417PCD: IP019 Rev 3VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD: IP019 Rev 3 / WF 36755591VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 07/31/2017VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 VIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
431752351O.M.P.M. SRLS02184,PQA598148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD: IP020 rev 2 / WF 53598597 small and large tanksVIA FONTAN 5ANGRI1084012Salvatore GaetaQA Manager(398)153-4251
PMSPQA918O.V.S. VILLELLA S.R.L.PQA918100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 VIA INCASALE, 13 21018 SESTO CALENDEITALY 11111Mr. Fabrizio De Tomasi (+39)QA Manager(033)192-2380
PMSPQA918O.V.S. VILLELLA S.R.L.PQA918103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007PCD: IO-011-LM rev A / WF 43604980VIA INCASALE, 13 21018 SESTO CALENDEITALY 11111Mr. Fabrizio De Tomasi (+39)QA Manager(033)192-2380
428429633OFFICINE MECCANICHE AERONAUTIC011397200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BPCD: NT64 rev Q WF 49449677 to 2ZZP00001 / Limitation TY 1B onlySPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016PCD: NT61 rev F and NT86 rev A / WF 40838388SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397606HEAT TREATMENTSAluminumAMS-2770 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397609HEAT TREATMENTSSteelAMS-2759 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397609CHEAT TREATMENTSSteel - PH, CRESAMS 2759/3 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397103NON-DESTRUCTIVE TESTINGMagnetic Particle InspectionLMA-PC007PCD: NT36-LMA rev.3 / WF 48372571SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PCD: NT 37-LMA rev 3 / WF 47134971 Approved for Non-Critical Parts and Critical PartsSPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 07/31/2017SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397240APAINT and PRIMEPrime and PaintMIL-F-18264 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Grandfathered / MIL-F-18264SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001PCD: NT153 rev E / WF 29441207SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001PCD: NT58 rev G NT87 rev C and NT153 rev H / WF 40832552SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001PCD: NT153 rev E / WF 29441207SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
428429633OFFICINE MECCANICHE AERONAUTIC011397251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 SPAVIA CAGLIARI 20FOLIGNO6006034Marco Gentili (+39)QA Manager(074)234-7538
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602200LANODIZESulfuric Acid AnodizeSTP 58-208PCD: 041-PE rev A WF 46965732PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602833BONDING AND COMPOSITESComposite Parts Surveillance and QualificationLMA-D0010 PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602844BONDING AND COMPOSITESFABRICATION OF EPOXY FOR C-130 PROGRAMSTP61-226 PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Limitation: Class 2 per STP58-405PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405PCD: 006-PE rev G / WF 52291968PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Limitation: Aluminum onlyPORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602600BHEAT TREATMENTSAluminumSTP 54-101Limitation 2024 and 7075PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602606HEAT TREATMENTSAluminumAMS-2770Limitation 2024 and 7075PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Limitation: STP53-201 onlyPORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602131ANON-DESTRUCTIVE TESTINGUltrasonic InspectionSTP 53-603 PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602230MPLATINGCadmium (C-130 ONLY)Process Spec 0491Limitation: TY II, Low Alloy MaterialsPORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011) PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101Limitation: 321 Stainless SteelPORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301PCD: 030-PE rev A WF 46591554PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602401AWELDINGFusion WeldingSTP 55-104 PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
452130628OGMA - INDUSTRIA AERONAUTICA D011198,101602404CWELDINGResistance WeldingSTP 55-005 PORTUGAL, S.A.PARQUE AERONAUTICO DE ALVERCAALVERCA DO RIBATEJO722615-173Ana LuisQA Manager 
007239130OXWELL, INC.100469171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 600 E 16TH STWELLINGTONKS671522803Gary Foster (ext-108)QA Manager(620)326-7481
007239130OXWELL, INC.100469600BHEAT TREATMENTSAluminumSTP 54-101 600 E 16TH STWELLINGTONKS671522803Gary Foster (ext-108)QA Manager(620)326-7481
007239130OXWELL, INC.100469606HEAT TREATMENTSAluminumAMS-2770 600 E 16TH STWELLINGTONKS671522803Gary Foster (ext-108)QA Manager(620)326-7481
786965103PAC-RANCHO, INC.435156,08305500ACASTINGSAluminum CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305500DCASTINGSFerrous CastingsFPS-1001 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613831%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305512ACASTINGSFerrous CastingsSTP53-400 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305512BCASTINGSNon-ferrous CastingsSTP53-400 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305516CASTINGSCastings, Aerospace QualityLMA-PA090 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305605AHEAT TREATMENTSSteelFPS-3014 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305605CHEAT TREATMENTSSteelFPS-1008, 17-4PH, Type 410 Corrosion Resistant 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305607HEAT TREATMENTSAluminum CastingsAMS-2771 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A and 1B.11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCDs QAP-7.13 Rev. 52 and QAP-7.14 Rev. 6 for 17-4 PH Steels Only.11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201QAP-7.13 Rev. 52 and QAP-7.14 Rev. 6. No Fracture Critical approval.11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305120BNON-DESTRUCTIVE TESTINGX-RayNDTS-3101 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301Approved PCD QAP-7.15 Rev. 3811000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Approved PCD's QAP 7.15 Rev. 38 and QAP-7.16 Rev. 0311000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Approved PCD QAP-7.10 Rev. 0511000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305401WELDINGFusion WeldingMIL-STD-2219REPAIR WELDING OF CASTINGS ONLY11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305405AWELDINGWeld Repair of CastingsFPS-1082 - AluminumAPPROVED WELDERS: Juan Ramon De Dios.11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305405BWELDINGWeld Repair of CastingsFPS-1082 - PH SteelAPPROVED WELDERS: Juan Ramon De Dios and Salvador Franco11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305406GWELDINGWeld Repair of CastingsSTP-55-801 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
786965103PAC-RANCHO, INC.435156,08305409WELDINGWeld Repair of CastingsAMS-2694 11000 JERSEY BLVDRANCHO CUCAMONGACA917305103Brian DarwishQA Manager(909)595-2252
154029078PACIFIC CAST TECHNOLOGIES, INC006781,00568502CASTINGSTitanium Castings5PTM3T01 150 QUEEN AVE SWALBANYOR973223306Paul WestQA Manager(541)967-4855
154029078PACIFIC CAST TECHNOLOGIES, INC006781,00568110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 150 QUEEN AVE SWALBANYOR973223306Paul WestQA Manager(541)967-4855
154029078PACIFIC CAST TECHNOLOGIES, INC006781,00568112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02Must use QCS-001 approved source for pre-penetrant etching.150 QUEEN AVE SWALBANYOR973223306Paul WestQA Manager(541)967-4855
154029078PACIFIC CAST TECHNOLOGIES, INC006781,00568120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 150 QUEEN AVE SWALBANYOR973223306Paul WestQA Manager(541)967-4855
067622142PACIFIC FORGE INCPQA677,12983513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 10641 ETIWANDA AVENUEFONTANACA92337Debra DoraQA Manager(909)390-0701
059328245PACIFIC METALLURGICAL, INC.PQA669160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 925 5TH AVENUE S. PO BOX 399KENTWA98032Kevin BillingtonQA Manager(253)854-4241
059328245PACIFIC METALLURGICAL, INC.PQA669601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875 925 5TH AVENUE S. PO BOX 399KENTWA98032Kevin BillingtonQA Manager(253)854-4241
059328245PACIFIC METALLURGICAL, INC.PQA669605AHEAT TREATMENTSSteelFPS-3014 925 5TH AVENUE S. PO BOX 399KENTWA98032Kevin BillingtonQA Manager(253)854-4241
059328245PACIFIC METALLURGICAL, INC.PQA669606HEAT TREATMENTSAluminumAMS-2770 925 5TH AVENUE S. PO BOX 399KENTWA98032Kevin BillingtonQA Manager(253)854-4241
399087147PARADIGM PRECISIONPQA097426ABRAZINGBrazingSTP 55-303 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097601AHEAT TREATMENTSSteelSTP54-019, Below 220 KSI 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097609HEAT TREATMENTSSteelAMS-2759 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097609AHEAT TREATMENTSSteel - Carbon and Low-Alloy LT 220 ksiAMS 2759/1 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097609DHEAT TREATMENTSSTEEL - AUSTENITIC CRESAMS 2759/4 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)LP5020 Cleaning and Degreasing for LM Aero Rev New1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097401AWELDINGFusion WeldingSTP 55-104 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097401AWELDINGFusion WeldingSTP 55-104 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097404CWELDINGResistance WeldingSTP 55-005 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
399087147PARADIGM PRECISIONPQA097404CWELDINGResistance WeldingSTP 55-005 1 BENTLEY WOOD WAY NETWORK 65 BUSINESS PARKHAPTON BURNLEY BB11 5TGPeter AllenQA Manager(128)283-1199
798910352PARAGON NDT, INC.012634,PQA661200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1B 1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725ambient 14 day cure only1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201SMPP 0002-38 rev B 1-30-20131015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201SMPP 0002-38 B F/D critical expires 3/18/2016 Steve Bauer1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301SMPP0001-22 Rev A, 3-25-20111015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661240APAINT and PRIMEPrime and PaintMIL-F-18264 1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.3/8/2010 Rev F1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
798910352PARAGON NDT, INC.012634,PQA661148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001SMPP 0007-8 Rev F1015 S. WEST ST.WICHITAKS67213Marcy RichardsonQA Manager(316)945-5285
SAPPQA997PARAGON SERVICESPQA997210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2434 S. SHERIDANWICHITAKS67217MarcyQA Manager(316)977-8887
SAPPQA997PARAGON SERVICESPQA997242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 2434 S. SHERIDANWICHITAKS67217MarcyQA Manager(316)977-8887
SAPPQA997PARAGON SERVICESPQA997240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 2434 S. SHERIDANWICHITAKS67217MarcyQA Manager(316)977-8887
808415041PARKER-HANNIFIN CORPORATION798400,04391426ABRAZINGBrazingSTP 55-303 3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301P2073 Rev NC3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)P2214 Rev E and P2064 Rev G3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391401AWELDINGFusion WeldingSTP 55-104 3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
808415041PARKER-HANNIFIN CORPORATION798400,04391404CWELDINGResistance WeldingSTP 55-005 3580 SHAW BLVDNAPLESFL341178408Scott HolderQA Manager(239)348-6350
787270834PATRIOT MACHINE, INC.010973,24946240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 76 S CORPORATE HILLS DRSAINT CHARLESMO633013744Mark C. KreutzerQA Manager(636)940-8200
PMSPQA866PCC STRUCTURALSPQA866512BCASTINGSNon-ferrous CastingsSTP53-400Limitations: No weld repair, Aluminum only35 INDUSTRIAL PARK DR.FRANKLINNH03235Joe SchappertQA Manager 
PMSPQA866PCC STRUCTURALSPQA866607HEAT TREATMENTSAluminum CastingsAMS-2771 35 INDUSTRIAL PARK DR.FRANKLINNH03235Joe SchappertQA Manager 
PMSPQA866PCC STRUCTURALSPQA866120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 35 INDUSTRIAL PARK DR.FRANKLINNH03235Joe SchappertQA Manager 
PMSPQA866PCC STRUCTURALSPQA866121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301PCD RI 4.0 x-ray rev AC / WF ID 3895582135 INDUSTRIAL PARK DR.FRANKLINNH03235Joe SchappertQA Manager 
004953852PCC STRUCTURALS, INC.006780,00407503CASTINGSTitanium Alloy Castings Ti6A1-4VLMA-M3001A 345 NE HEMLOCK AVEREDMONDOR977561430Amanda YounessionQA Manager(541)316-2659
004953852PCC STRUCTURALS, INC.006780,00407602HEAT TREATMENTSTitaniumAMS-H-81200 345 NE HEMLOCK AVEREDMONDOR977561430Amanda YounessionQA Manager(541)316-2659
004953852PCC STRUCTURALS, INC.006780,00407110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 345 NE HEMLOCK AVEREDMONDOR977561430Amanda YounessionQA Manager(541)316-2659
004953852PCC STRUCTURALS, INC.006780,00407120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 345 NE HEMLOCK AVEREDMONDOR977561430Amanda YounessionQA Manager(541)316-2659
004953852PCC STRUCTURALS, INC.006780,00407123NON-DESTRUCTIVE TESTINGX-RayLMA-PC301Approved Procedure NDT 300 Revision 12.345 NE HEMLOCK AVEREDMONDOR977561430Amanda YounessionQA Manager(541)316-2659
009586413PEEN-RITE, INCS01194,26736310SHOT PEENINGShot PeeningAMS 2430 11662 SHELDON STSUN VALLEYCA913521597Mike GarciaQA Manager(818)767-3676
009586413PEEN-RITE, INCS01194,26736310ASHOT PEENINGShot PeeningMIL-S-13165/AMS-S-13165VENDOR DOES NOT PERFORM POST PEEN CLEANING11662 SHELDON STSUN VALLEYCA913521597Mike GarciaQA Manager(818)767-3676
009586413PEEN-RITE, INCS01194,26736311SHOT PEENINGShot PeeningSTP51-501VENDOR DOES NOT PERFORM POST PEEN CLEAINING11662 SHELDON STSUN VALLEYCA913521597Mike GarciaQA Manager(818)767-3676
009586413PEEN-RITE, INCS01194,26736313SHOT PEENINGShot PeeningLADC-P-70-1038 / LCP70-1038VENDOR DOES NOT PERFORM POST PEEN CLEANING11662 SHELDON STSUN VALLEYCA913521597Mike GarciaQA Manager(818)767-3676
009586413PEEN-RITE, INCS01194,26736314SHOT PEENINGShot PeeningPS C-1476VENDOR DOES NOT PERFORM POST PEEN CLEANING. Approved PCD DPM M-03 Sec. 21 Rev. E.11662 SHELDON STSUN VALLEYCA913521597Mike GarciaQA Manager(818)767-3676
135833767PEENING TECHNOLOGIES OF GEORGIS02342,PQA604310SHOT PEENINGShot PeeningAMS 2430 3117 EMERY CIRCLEAUSTELLGA30106Sean NickersonQA Manager(770)941-9573
135833767PEENING TECHNOLOGIES OF GEORGIS02342,PQA604311SHOT PEENINGShot PeeningSTP51-501NO POST SHOT PEENING CHEMICAL CLEANING3117 EMERY CIRCLEAUSTELLGA30106Sean NickersonQA Manager(770)941-9573
135833767PEENING TECHNOLOGIES OF GEORGIS02342,PQA604311SHOT PEENINGShot PeeningSTP51-501NO POST SHOT PEENING CHEMICAL CLEANING3117 EMERY CIRCLEAUSTELLGA30106Sean NickersonQA Manager(770)941-9573
135833767PEENING TECHNOLOGIES OF GEORGIS02342,PQA604314SHOT PEENINGShot PeeningPS C-1476QAD 75.0 Rev N/C per WF432261333117 EMERY CIRCLEAUSTELLGA30106Sean NickersonQA Manager(770)941-9573
113267637PERFEKTA INC.013441,PQA658167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 480 EAST 21ST STREETWICHITAKS67214Bill R. JarrellsQA Manager(316)706-5000
113267637PERFEKTA INC.013441,PQA658168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 480 EAST 21ST STREETWICHITAKS67214Bill R. JarrellsQA Manager(316)706-5000
113267637PERFEKTA INC.013441,PQA658240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 480 EAST 21ST STREETWICHITAKS67214Bill R. JarrellsQA Manager(316)706-5000
008365256PERVAN TOOLING COMPANY, INC.009380,08539160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1716 KONA DRCOMPTONCA902205487Ray GomezQA Manager(310)639-6331
008365256PERVAN TOOLING COMPANY, INC.009380,08539161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1716 KONA DRCOMPTONCA902205487Ray GomezQA Manager(310)639-6331
008365256PERVAN TOOLING COMPANY, INC.009380,08539167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1716 KONA DRCOMPTONCA902205487Ray GomezQA Manager(310)639-6331
008365256PERVAN TOOLING COMPANY, INC.009380,08539168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1716 KONA DRCOMPTONCA902205487Ray GomezQA Manager(310)639-6331
008365256PERVAN TOOLING COMPANY, INC.009380,08539240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 1716 KONA DRCOMPTONCA902205487Ray GomezQA Manager(310)639-6331
008365256PERVAN TOOLING COMPANY, INC.009380,08539240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 1716 KONA DRCOMPTONCA902205487Ray GomezQA Manager(310)639-6331
362912065PRECISION AEROSPACE CORP006125300ACHEM MILLING / DESCALINGAluminum Chem MillingFPS-1051PCD: PPS 2.010 Rev. 1 Pending Approval: WF ID 5288005311155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125300CCHEM MILLING / DESCALINGSteel Chem MillingFPS-1051 11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125300DCHEM MILLING / DESCALINGTitanium Chem MillingFPS-1051PCD: PPS 2.020 Rev. 5 Pending Approval: WF ID 5288157511155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125300ECHEM MILLING / DESCALING10 Nickel Steel Chem MillingFPS-1051 11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125302CHEM MILLING / DESCALINGChem MillingMIL-C-81769 11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125303CHEM MILLING / DESCALINGAluminum Chem Milling5PTPAL04 11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125304CHEM MILLING / DESCALINGChemical Milling of MetalsLMA-PA051ALUMINUM, FERROUS, TITANIUM and INCONEL ALLOYS.11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125305CHEM MILLING / DESCALINGChemical MillingPS 0450Approved for Aluminum (Type I) Only.11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
362912065PRECISION AEROSPACE CORP006125306CHEM MILLING / DESCALINGChem MillingPS 1506Aluminum Only. Approved PCD PPS 2.0102 Rev. 1 (4/4/12) (WF-ID 41854950).11155 JERSEY BLVD STE ARANCHO CUCAMONGACA917305148Jim StephensQA Manager(909)980-8855
003982709PRECISION METALSMITHS, INC.PQA676512ACASTINGSFerrous CastingsSTP53-400 1149 NORTH MARGARET STREETMARKESANWI53946Gary BerghammerQA Manager(920)398-2361
003982709PRECISION METALSMITHS, INC.PQA676110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 1149 NORTH MARGARET STREETMARKESANWI53946Gary BerghammerQA Manager(920)398-2361
003982709PRECISION METALSMITHS, INC.PQA676111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 1149 NORTH MARGARET STREETMARKESANWI53946Gary BerghammerQA Manager(920)398-2361
003982709PRECISION METALSMITHS, INC.PQA676120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 1149 NORTH MARGARET STREETMARKESANWI53946Gary BerghammerQA Manager(920)398-2361
003982709PRECISION METALSMITHS, INC.PQA676121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301SOP QC-10.8.2 Rev H approved Marietta Level III 9/24/091149 NORTH MARGARET STREETMARKESANWI53946Gary BerghammerQA Manager(920)398-2361
008492076PRECISION TUBE BENDING008927,27096168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009Limited to Webster Plier Testing for Tubing.13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Excludes Zones 1A, 1B, and 1C. Must utilize QCS-001 source for pre-penetrant etching13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Excludes LCP72-1068.13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved for Non-Critical Parts and Critical Parts. Not Approved For Fracture Critical Parts. Procedure QAP 8.2.5 Rev. M.13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013Approved procedures PPS 105-1 Rev. A for chemfilm and PPS 105-2 Rev. N/C for paint13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096401AWELDINGFusion WeldingSTP 55-104 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096406AWELDINGFusionFPS-1095, Steel 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096406BWELDINGFusionFPS-1095, Corrosion Resistant Steels 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096406CWELDINGFusionFPS-1095, Copper Nickel Alloys 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096406DWELDINGFusionFPS-1095, Aluminum 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096406EWELDINGFusionFPS-1095, Titanium 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096408WELDINGFusion5PTPET01 13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
008492076PRECISION TUBE BENDING008927,27096408AWELDINGFUSION WELDING - F-352ZZP00013Approved Cleaning PCD's PPS 104-7 Rev. C for Ti and PPS 104-8 Rev. C for Al (WF ID -45392947)13626 TALC STSANTA FE SPRINGSCA906705173John PhippsQA Manager(562)407-3200
605959006PRIDE PLATING005037,02952200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BType 1B approval only.2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200CANODIZEHard AnodizeMIL-A-8625, Type IIILimiting 2124 engine rails to small line (100)2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200HANODIZEChromic Acid AnodizeSTP 58-209Approval is for Type 1 only2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200LANODIZESulfuric Acid AnodizeSTP 58-208PP 4 Sulfuric Anodize Rev. L approved2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200OANODIZEHard AnodizeSTP 58-206 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200PANODIZEHard AnodizeProcess Spec C-0445 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200P1ANODIZEHard AnodizePS0445 Hard Anodizing of Aluminum Alloys 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200P1ANODIZEHard AnodizePS0445 Hard Anodizing of Aluminum Alloys 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952200SANODIZEChromic Acid Anodize2ZZP00001MIL-A-8625 Type IB2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952205ACHEMICAL CONVERSION COATINGTitanium Fluoride-Phosphate Coating5PTPHG16 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952206CHEMICAL CONVERSION COATINGTitanium Conversion CoatingAMS-2486 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952207CHEMICAL CONVERSION COATINGTitanium Conversion CoatingFPS-0116PP 7.1 Rev. P2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952210ACHEMICAL CONVERSION COATINGChem FilmSTP 58-405PP7, Rev. R2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952210BCHEMICAL CONVERSION COATINGChem FilmProcess Spec C-0498PP 7 Rev Q 03/03/20102900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952211CHEMICAL CONVERSION COATINGTitanium Conversion CoatingLMA-PH016P.P 7.2 Rev. D2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952242DFUEL TANK COATINGFuel Tank CoatingSTP 59-505PP 14 Rev E 06/07/20102900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952242EFUEL TANK COATINGFuel Tank CoatingProc Bulletin G639PP14 Rev E dated 06/07/20102900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952166HEAT TREAT VERIFICATIONHardness / Conductivity of Aluminum5PTPTL19 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110BNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.INCLUDES ZONES 1A, 1B AND 1C2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110DNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1A Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.INCLUDES ZONES 1A, 1B AND 1C2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110ENON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1B Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.INCLUDES ZONES 1A, 1B AND 1C2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110FNON-DESTRUCTIVE TESTINGPenetrant InspectionNDTS-1101, Zone 1C Fracture Critical - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.INCLUDES ZONES 1A, 1B AND 1C2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068Approval excludes LCP-72-1068.2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952112NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02PP5 Rev S2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952112ANON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCL02 Fracture Critical including Critical HardwarePP 5 Rev S2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952112BNON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) Fracture Critical Dem Prog5PTPCL02 including Critical HardwareApproved for Fracture Critical Parts, Facility Qualification approval expires 01/31/20172900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201PP 5 Rev S2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952113aNON-DESTRUCTIVE TESTINGPenetrant Inspection Fracture CriticalLMA-PC201Approved for Fracture Critical Parts, Facility Qualification approval expires 03/31/20172900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146NON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06PP 5 Rev S2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146ANON-DESTRUCTIVE TESTINGPenetrant Inspection5PTPCG06 Fracture CriticalApproved for Fracture Critical Parts, Facility Qualification approval expires 03/31/20172900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952240APAINT and PRIMEPrime and PaintMIL-F-18264 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264Approved for stripping of coatings per PP-105 A Stripping of Coatings Rev. New2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)PP 26 Rev. E2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110C1PRE-PENETRANT ETCHPre-Penetrant Etch - AluminumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110C2PRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952110C3PRE-PENETRANT ETCHPre-Penetrant Etch - SteelNDTS-1101 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18416114%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be allowed for processing. Refer to the process code to determine sources.Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B1PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGG01Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B2PRE-PENETRANT ETCHPre-Penetrant Etch - Titanium5PTPGG01Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B3PRE-PENETRANT ETCHPre-Penetrant Etch - PH and CRES5PTPGG01Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B4PRE-PENETRANT ETCHPre-Penetrant Etch - Nickel Alloys5PTPGG01Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B5PRE-PENETRANT ETCHPre-Penetrant Etch - Titanium5PTPGL01Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B6PRE-PENETRANT ETCHPre-Penetrant Etch - Aluminum5PTPGL03Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952146B7PRE-PENETRANT ETCHPre-Penetrant Etch - PH Steels and Nickel Alloys5PTPGL04Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952148PRE-PENETRANT ETCHPre-Penetrant Etch-AluminumLMA-PG001GRO-PP 045-001 Rev. C2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952148aPRE-PENETRANT ETCHPre-Penetrant Etch - TitaniumLMA-PG001Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952148bPRE-PENETRANT ETCHPre-Penetrant Etch - PH/Cres SteelsLMA-PG001Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952148cPRE-PENETRANT ETCHPre-Penetrant Etch - Nickel AlloysLMA-PG001Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101Procedure PP 5.2, Rev AN2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952619PRE-PENETRANT ETCHAluminum Alloys-Alkaline/Acid Metal Remova MethodsSTP57-301Excludes any 7000 series aluminum parts that will have any bare areas post anodize.2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952620PRE-PENETRANT ETCHTitanium Alloys-Alkaline/Acid Metal Remova MethodsSTP57-401 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952250ASOLID FILM LUBRICANTSSolid Film Lubricant - Solvent BaseFPS-3006 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614032%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Applicator Approved: Cheryl Ford2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952250A1SOLID FILM LUBRICANTSSOLID FILM LUBRICANTS - WATER BASEFPS-3006 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14614032%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources.Applicator Approved: Cheryl Ford2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952252SOLID FILM LUBRICANTSSolid Film LubricantSTP 62-005 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
605959006PRIDE PLATING005037,02952253SOLID FILM LUBRICANTSSolid Film LubricantsP62001 (supersedes LADC-P-81-2064) 2900 E. HIGHWAY 10GROVEOK74344Christopher DintelmannQA Manager 
PMSPQA647PROTOCASTPQA647512ACASTINGSFerrous CastingsSTP53-400Investment Castings.9732 COZY CROFT AVECHATSWORTHCA91311Patrick ListQA Manager(818)882-7848
131008299QUALITY MATERIAL INSPECTION INCPQA697136NON-DESTRUCTIVE TESTINGEddy Current5PTPCT02FRACTURE CRITICAL APPROVED5442 OCEANUS DRIVEHUNTINGTON BEACHCA92649Karin Grandia-BlinnQA Manager(714)903-4500
131008299QUALITY MATERIAL INSPECTION INCPQA697136ANON-DESTRUCTIVE TESTINGEddy Current5PTPCT02 Fracture CriticalCategory 2 only5442 OCEANUS DRIVEHUNTINGTON BEACHCA92649Karin Grandia-BlinnQA Manager(714)903-4500
131008299QUALITY MATERIAL INSPECTION INCPQA697136BNON-DESTRUCTIVE TESTINGEddy Current5PTPCT12 5442 OCEANUS DRIVEHUNTINGTON BEACHCA92649Karin Grandia-BlinnQA Manager(714)903-4500
131008299QUALITY MATERIAL INSPECTION INCPQA697139NON-DESTRUCTIVE TESTINGEddy CurrentLMA-PC002 5442 OCEANUS DRIVEHUNTINGTON BEACHCA92649Karin Grandia-BlinnQA Manager(714)903-4500
131008299QUALITY MATERIAL INSPECTION INCPQA697163NON-DESTRUCTIVE TESTINGEddy CurrentNDTS-1601 5442 OCEANUS DRIVEHUNTINGTON BEACHCA92649Karin Grandia-BlinnQA Manager(714)903-4500
746201917QUICKSTEP AEROSPACE PTY LTDS01892833BONDING AND COMPOSITESComposite Parts Surveillance and QualificationLMA-D0010 361 MILPERRA RDBANKSTOWN102200Fabio GasparottoQA Manager(297)740-333
746201917QUICKSTEP AEROSPACE PTY LTDS01892844BONDING AND COMPOSITESFABRICATION OF EPOXY FOR C-130 PROGRAMSTP61-226Qualification Report 247 Dated June 2013361 MILPERRA RDBANKSTOWN102200Fabio GasparottoQA Manager(297)740-333
746201917QUICKSTEP AEROSPACE PTY LTDS01892131ANON-DESTRUCTIVE TESTINGUltrasonic InspectionSTP 53-603 361 MILPERRA RDBANKSTOWN102200Fabio GasparottoQA Manager(297)740-333
746201917QUICKSTEP AEROSPACE PTY LTDS01892247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 361 MILPERRA RDBANKSTOWN102200Fabio GasparottoQA Manager(297)740-333
079253466RBC AEROSTRUCTURES LLCS02442169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.) 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442606HEAT TREATMENTSAluminumAMS-2770 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442614HEAT TREATMENTSStress Relieving, Baking and Cold Treatment of SteelSTP54-008 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442240APAINT and PRIMEPrime and PaintMIL-F-18264 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442246PAINT and PRIMEEpoxy Primer/Polyurethane Top CoatG700 (Approval required by 01-01-2014) 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442247PAINT and PRIMEApplication of Finish for C130 HardwareG604 (Approval required by 01-01-2014) 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442239CPHOSPHATEPhospateSTP 58-302 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442230BPLATINGCadmiumQQ-P-416 Type II 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442230MPLATINGCadmium (C-130 ONLY)Process Spec 0491 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442251SOLID FILM LUBRICANTSSolid Film LubricantMIL-L-46010 / MIL-PRF-46010 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442401AWELDINGFusion WeldingSTP 55-104 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
079253466RBC AEROSTRUCTURES LLCS02442412AWELDINGFlash WeldingSTP 55-601 123 COMMERCE WAYWESTMINSTERSC296933939Doug Starzec ex 2811QA Manager(864)886-4600
002955649RHEACO, INC.755859,23428210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428171HEAT TREAT VERIFICATIONHardness/Conductivity Inspec. Wrought Alum AlloyAMS 2658 (Effective 01-01-2014) (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)procedure 4.09-3PI 211801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
002955649RHEACO, INC.755859,23428240BPAINT and PRIMETouchup Rqmts for Chemical and Organic FinishesLMA-PJ013 1801 W JEFFERSON STGRAND PRAIRIETX750511328James RozellQA Manager(972)314-8018
PMSPQA771SAM WOO METAL IND.CO.PQA771200BANODIZESulfuric Acid AnodizeMIL-A-8625 Type II 604-17 NAMSAN-DONGCHANGWON CITY, KOREA  Sung Mun Seo [+82]QA Manager(055)282-4236
PMSPQA771SAM WOO METAL IND.CO.PQA771615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Limited to passivation of Corrosion Resistant Steel alloys SW-PI-01 Rev., Amendment No. 5.604-17 NAMSAN-DONGCHANGWON CITY, KOREA  Sung Mun Seo [+82]QA Manager(055)282-4236
076720671SAVAGE PRECISION FABRICATION,001196,24813242AFUEL TANK COATINGFuel Tank CoatingMIL-C-27725/AMS-C-27725 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813242BFUEL TANK COATINGFuel Tank CoatingFPS-1004 - (Application MIL-C-27725/AMS-C-27725 Material). This is a special process requiring monitoring and approval by SQM, so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=18678872%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the process code for approved sources. 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813164HEAT TREAT VERIFICATIONHardness Testing5PTPCG09 Appendix A 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813165HEAT TREAT VERIFICATIONConductivity Testing5PTPCG09 Appendix B 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813166HEAT TREAT VERIFICATIONHardness / Conductivity of Aluminum5PTPTL19 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813606HEAT TREATMENTSAluminumAMS-2770Approved for solution HT. No aging of 7049, 7149, 7249, and 7050.1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813240APAINT and PRIMEPrime and PaintMIL-F-18264 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813240CPAINT and PRIMEAPPLICATION AND CONTROL OF ORGANIC FINISHESLMA-PJ264 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
076720671SAVAGE PRECISION FABRICATION,001196,24813406DWELDINGFusionFPS-1095, Aluminum 1415 MARTINEZ LNWYLIETX750984075Ozzie ChairezQA Manager(972)429-0993
089039515SCARROTT METALLURGICAL CO.004818,PQA769,09745425BBRAZINGFurnace BrazingMIL-B-7883 TYPE IIEXCLUDING ALUMINUM ALLOYS6371 ARIZONA CIRCLELOS ANGELESCA90045Navid KhalilianQA Manager(310)645-7300
089039515SCARROTT METALLURGICAL CO.004818,PQA769,09745426ABRAZINGBrazingSTP 55-303 6371 ARIZONA CIRCLELOS ANGELESCA90045Navid KhalilianQA Manager(310)645-7300
SAPPQA930SENIOR AEROSPACE ERMETOPQA930110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 ZA EURO VAL DE LOREFOSSE 41330 FR  Mr. Eric Mitard (+33)QA Manager(254)335-088
SAPPQA930SENIOR AEROSPACE ERMETOPQA930111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068 ZA EURO VAL DE LOREFOSSE 41330 FR  Mr. Eric Mitard (+33)QA Manager(254)335-088
SAPPQA930SENIOR AEROSPACE ERMETOPQA930615PRE-PENETRANT ETCHCleaning (Alkaline/Acid Removal Methods Only)PS 0170 (APPROVAL REQUIRED EFFECTIVE 1/1/2011)Revision C ApprovedZA EURO VAL DE LOREFOSSE 41330 FR  Mr. Eric Mitard (+33)QA Manager(254)335-088
SAPPQA930SENIOR AEROSPACE ERMETOPQA930617PRE-PENETRANT ETCHCorrosion-Alkaline/Acid Metal Removal Methods OnlySTP57-101 ZA EURO VAL DE LOREFOSSE 41330 FR  Mr. Eric Mitard (+33)QA Manager(254)335-088
SAPPQA930SENIOR AEROSPACE ERMETOPQA930401AWELDINGFusion WeldingSTP 55-104 ZA EURO VAL DE LOREFOSSE 41330 FR  Mr. Eric Mitard (+33)QA Manager(254)335-088
884237785SENIOR OPERATIONS LLC829783,15920110ANON-DESTRUCTIVE TESTINGPenetrant InspectionMIL-STD-6866/ASTM-E-1417 2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920111ANON-DESTRUCTIVE TESTINGPenetrant InspectionSTP53-201/LCP72-1068STP53-201 approval only. Approved cleaning PCD number MPP-66, Supplement number 2, N/C.2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920113NON-DESTRUCTIVE TESTINGPenetrant (Fluorescent) InspectionLMA-PC201Approved Procedure MPD-44 Supp. 25 Rev. B. Not approved for Fracture Critical Hardware. Approved cleaning PCD MPD 66 Supp. number 2, Rev. N/C. Must use QCS-001 source for pre-penetrant etching.2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920120ANON-DESTRUCTIVE TESTINGX-RayMIL-STD-453 / ASTM-E-1742 2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920121ANON-DESTRUCTIVE TESTINGX-RaySTP 53-301FOR C-130 WORK ONLY. Approved PCD MPD-83 Supp. 4 dated 3-24-2010.2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920401WELDINGFusion WeldingMIL-STD-2219 2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920401AWELDINGFusion WeldingSTP 55-104Approved cleaning PCD number MPP-66, Supplement number 2, N/C.2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920404BWELDINGResistance WeldingMIL-W-6858Excludes Class A. Excludes Group 1 (aluminum and magnesium).2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920404CWELDINGResistance WeldingSTP 55-005Excludes Class A welds. Excludes Group a (aluminum) material. Approved cleaning PCD number MPP-66, Supplement number 2, N/C.2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
884237785SENIOR OPERATIONS LLC829783,15920408AWELDINGFUSION WELDING - F-352ZZP00013Approved cleaning procedure MPD-30, Rev. V, Supp. number 3, rev. N/C. Excludes Class C welds.2980 N SAN FERNANDO BLVDBURBANKCA915042522Marcal KingQA Manager(818)260-2981
021507603SHELTON INDUSTRIAL PATTERN, INS00611,PQA893160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501 8925 ZEV AVENUESt. LouisMO63134Tim EinspornQA Manager(314)521-4401
021507603SHELTON INDUSTRIAL PATTERN, INS00611,PQA893161HEAT TREAT VERIFICATIONConductivity TestingNDTS-1500 / 1502 8925 ZEV AVENUESt. LouisMO63134Tim EinspornQA Manager(314)521-4401
021507603SHELTON INDUSTRIAL PATTERN, INS00611,PQA893167HEAT TREAT VERIFICATIONConductivity TestingLMA-PC009 8925 ZEV AVENUESt. LouisMO63134Tim EinspornQA Manager(314)521-4401
021507603SHELTON INDUSTRIAL PATTERN, INS00611,PQA893168HEAT TREAT VERIFICATIONHardness TestingLMA-PC009 8925 ZEV AVENUESt. LouisMO63134Tim EinspornQA Manager(314)521-4401
021507603SHELTON INDUSTRIAL PATTERN, INS00611,PQA893606HEAT TREATMENTSAluminumAMS-2770 8925 ZEV AVENUESt. LouisMO63134Tim EinspornQA Manager(314)521-4401
009593567SHULTZ STEEL COMPANY802479,15292510BFORGINGSSteel ForgingsFPS-1041 - This is a special process requiring monitoring and approval by Supplier Quality Management (SQM), so not all of the processors listed on the Qualified Processors List at (https://edcs01.lmtas.com/main/livelink?func=ll%26objId=14613834%26objAction=Open%26nexturl=%2Fmain%2Flivelink%3Ffunc%3Dll%26objId%3D14440676%26objAction%3Dbrowse%26viewType%3D1) may be currently allowed for processing. Refer to the specific process code to determine approved sources. 5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292514FORGINGSForgingLMA-PA041 5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292160HEAT TREAT VERIFICATIONHardness TestingNDTS-1500 / 1501Limited to Brinell Testing Only.5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292601HEAT TREATMENTSSTEELMIL-H-6875/AMS-H-6875LIMITED TO NORMALIZE ANNEAL, STRESS RELIEF AND PRE-HEAT5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292602HEAT TREATMENTSTitaniumAMS-H-81200LIMITED TO NORMALIZE, ANNEAL, STRESS RELIEF AND PRE-HEAT5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292604HEAT TREATMENTSD6AC SteelFPS-1029LIMITED TO NORMALIZE, ANNEAL, STRESS RELIEF AND PRE-HEAT5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444 5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292100BNON-DESTRUCTIVE TESTINGMagnetic Particle InspectionNDTS-2101Approved cleaner: Acetone only.5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292130ANON-DESTRUCTIVE TESTINGUltrasonic InspectionMIL-STD-2154 / AMS-STD-2154 5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
009593567SHULTZ STEEL COMPANY802479,15292130BNON-DESTRUCTIVE TESTINGUltrasonic InspectionNDTS-5101 5321 FIRESTONE BLVDSOUTH GATECA902803629Steve GoodeQA Manager(323)564-3281
004154407SIFCO INDUSTRIES013188,PQA738513EFORGINGSFerrous ForgingsSTP51-320 - replaced LAC 0562 970 EAST 64TH STREETCLEVELANDOH441031620Elizabeth ZumwaltQA Manager(216)426-2822
004154407SIFCO INDUSTRIES013188,PQA738169HEAT TREAT VERIFICATIONHardness Conductivity and Tensile StrengthDS30005 (If the required conversion table is not available, submit an eSPaR and reference TDA DH57079, to request appropriate direction for continued processing.)Hardness only.970 EAST 64TH STREETCLEVELANDOH441031620Elizabeth ZumwaltQA Manager(216)426-2822
004154407SIFCO INDUSTRIES013188,PQA738100ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionMIL-STD-1949/ASTM-E-1444Inspection in as-forged condition only970 EAST 64TH STREETCLEVELANDOH441031620Elizabeth ZumwaltQA Manager(216)426-2822
004154407SIFCO INDUSTRIES013188,PQA738101ANON-DESTRUCTIVE TESTINGMagnetic Particle InspectionSTP 53-001Inspection in as-forged condition only.970 EAST 64TH STREETCLEVELANDOH441031620Elizabeth ZumwaltQA Manager(216)426-2822
PMSPQA794SIGNATURE AEROSPACEPQA794244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014) 6090 VANDEN ABEELESAINT LAURENT, QUEBEC60H4S 1R9Jill WhitelowQA Manager(514)333-4703
228078531SLINGSBY ADVANCED COMPOSITES100362,01481815BONDING AND COMPOSITESC-130J TRIM PANEL FABRICATIONSTP61-404 LIMITEDINGS LANEYORK30YO62 6EZEmma Sherbourne (011 44)QA Manager(017)514-3466
962259276SNOWLINE AEROSPACE, INC.S01039816BONDING AND COMPOSITESApplication of AdhesivesPS 0101Approved PCD LPCD-1020, rev. 1.6. Approved for Types I, II, III, IV, IVb, Vb, VI, VII, VIII, and XII.4261 BUSINESS DRCAMERON PARKCA956827217Vern Holzer x319QA Manager(530)677-2675
962259276SNOWLINE AEROSPACE, INC.S01039426ABRAZINGBrazingSTP 55-303Torch Brazing Only. Approved brazing PCD LPCD-1014, revision 1.2. Approved cleaning PCD LPCD-1016, rev. 1.04261 BUSINESS DRCAMERON PARKCA956827217Vern Holzer x319QA Manager(530)677-2675
962259276SNOWLINE AEROSPACE, INC.S01039240APAINT and PRIMEPrime and PaintMIL-F-18264 4261 BUSINESS DRCAMERON PARKCA956827217Vern Holzer x319QA Manager(530)677-2675
962259276SNOWLINE AEROSPACE, INC.S01039244PAINT and PRIMEAppl. of epoxy primer and polyurethane coating systeC-378-M (Approval required by 01-01-2014)Approved PCD LPCD-1021, revision 1.1. Approvals exclude MIL-C-83286 and MIL-PRF-85582 materials.4261 BUSINESS DRCAMERON PARKCA956827217Vern Holzer x319QA Manager(530)677-2675
962259276SNOWLINE AEROSPACE, INC.S01039401AWELDINGFusion WeldingSTP 55-104GTAW Only. Approved internal cleaning PCD LPCD-1017, Rev. 01.4261 BUSINESS DRCAMERON PARKCA956827217Vern Holzer x319QA Manager(530)677-2675
962259276SNOWLINE AEROSPACE, INC.S01039404EWELDINGResistance WeldingC-1421Group 2 material only. Approved PCD LPCD-1013, rev. 1.1. Approved external cleaning PCD WI-ACT-0050. Approved internal cleaning of assemblies PCD LPCD-1018, rev. 1.0.4261 BUSINESS DRCAMERON PARKCA956827217Vern Holzer x319QA Manager(530)677-2675
370009847SOCIETE ANONYME BELGE DE811150200AANODIZEChromic Acid AnodizeMIL-A-8625, Type 1 and Type 1BPCD: MT_32_0904 r 14 / MT32_0904 APP1 r 5 / WF 46695091 Limitation: Not approved for F-35CONSTRUCTIONS AERONAUTIQUES SACHAUSSEE DE HAECHT 1470BRUXELLES151130Josianne EvrardQA Manager(272)955-560
370009847SOCIETE ANONYME BELGE DE811150200CANODIZEHard AnodizeMIL-A-8625, Type III CONSTRUCTIONS AERONAUTIQUES SACHAUSSEE DE HAECHT 1470BRUXELLES151130Josianne EvrardQA Manager(272)955-560
370009847SOCIETE ANONYME BELGE DE811150210CHEMICAL CONVERSION COATINGChem FilmAMS-C-5541/MIL-DTL-5541, Type I, Class 1A and Class 3Limitation: CL 1A. Brush application only. Not approved for F-35